close
Filter By
Company
Approvals
Connection Type
Material Spec
Measuring range
Medium Temperature
Nominal Pressure
- 0...25 bar 1
- 10...2200 bar 2
- 365 bar 1
- 410 bar 2
- DN 20...DN 40__DN 50 1
- DN 25__DN 50... DN 80 1
- DN 150...DN 300__DN 350...DN 600__DN 65...DN 120 1
- DN 150...DN 300__DN 350...DN 800__DN 65...DN 125 3
- DN 150__PN 25 1
- DN 250__DN 300__DN 80...DN 200 1
- DN 350...DN 800__DN 60...DN 300 1
- DN 350...DN 800 L3FM-T__DN 65...DN300 L3FM-T 1
- PN 10 5
- PN 16 12
- PN 25 8
- PN25 1
- PN 40 6
Nominal Size
DN 150...DN 300__DN 350...DN 600__DN 65...DN 120, 365 bar - PN 16
14 items

SITRANS FC MASS 2100 DI 1.5
3548
The SIEMENS SITRANS FC MASS 2100 DI 1.5 has demonstrated superior performance in numerous applications and field trials relating to mass flow- and density accuracy and turndown ratio. The single continuous tube design without internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food and beverage and pharmaceutical applications. The SITRANS F C MASS 2100 DI 1.5 is today the preferred meter for research and development and mini-plant applications for liquid or gas measurement, where measuring minimal quantities (e.g. drops per hour) is important. To make a complete flowmeter, the SITRANS F C MASS 2100 flow sensor must be combined with one of the following MASS transmitters: SIFLOW FC070 : For direct integration into SIMATIC based systems
- USD

L1S 2-way Control Valve
7389
The Clorius Controls L1S 2-way control valve components spindle, seat and cone are made of stainless steel. The L1S valve body is made of gunmetal RG 5. The thread for the actuator connection is G1B ISO 228. The valve is single seated. The leakage rate is less than 0.05% of the full flow (according to VDI/VDE 2174). Without the actuator being connected, the Clorius L1S control valve is held in an open position using a spring. With pressure on the spindle, the valve will close. In connection with thermostats, pneumatic or electric actuators, the valve will close at rising temperatures. For cooling circuits, the valve can be used in conjunction with a reverse acting electric actuator. Alternatively, a reverse acting valve can be used with our self-acting thermostats. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

M1FBN 2-way Control Valve
8960
The Clorius type M1FBN 2-way balanced control valve is designed for regulating hot water, steam and hot oil systems. Balanced valves are used in installations where the system pressure necessitates a closing force greater than available in the actuator programme for a standard single-seated valve, and where the leakage rate for a double-seated valve is unacceptable. The type M1FBN control valve is used in conjunction with our temperature or pressure differential regulators for controlling industrial processes, district or central heating plants or marine installations. Design The valve components, spindle, seat and cone – are made of stainless steel. The M1FBN body is made of cast iron EN-GJS-400-15 with flanges drilled according to EN 1092-2 or ANSI B16.5 Class 150. The thread for the actuator connection is G1B ISO 228. The valves are single-seated. The leakage rate is less than 0.05% of the full flow (according to VDI/VDE 2174). Function Without an actuator being connected, the valve is held in an open position using a spring. With force on the spindle, the valve will close. In connection with our thermostats, pneumatic or electric actuators, the valves will close at rising temperatures. For cooling circuits, the valve can be used in conjunction with a reverse acting electric actuator. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

L1SBR (Reverse Acting) 2-way Control Valve
8971
The Clorius L1SBR (reversed acting) 2-way control valve is mainly designed for the regulation of cooling water and lubricating liquids. The L1SBR balanced valve is used in installations where the system pressure necessitates a closing force greater than available in the actuator programme for a standard single-seated valve, and where the leakage rate for a double-seated valve is unacceptable. The valves are installed combined with Clorius self-acting thermostats, pressure differential regulators or electric actuators for regulation in industrial plants, industrial processes or marine installations – especially in control systems for cooling. Design The valve components – spindle, seats and cone – are made of stainless steel. The valve body is made of gunmetal RG 5. The thread for the actuator connection is G1B ISO 228. The valve is single-seated, balanced. The leakage rate is less than 0.05% of the full flow (according to VDI/VDE 2174). Function Without the actuator being connected, the valve is held in a closed position by means of a spring. With pressure on the spindle, the valve opens. In connection with our thermostats, the valves will open at rising temperatures. In connection with our electric actuators, the valves will either close or open, depending on the application. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

G2FR (Reverse Acting) 2-way Control Valve
8984
The Clorius G2FR (reverse acting) 2-way control valve is mainly intended to control cooling systems. The G2FR control valve is used in conjunction with temperature- or pressure differential regulators. As the reverse acting valve is held in a closed position using a built-in spring, the max. differential pressure, ΔpL, against which a valve can close depends on the spring, and when opening the valve, the actuator has to overcome the spring force. See datasheet to find the max. allowable values of ΔpL as well as the max. allowable inlet pressures for opening the valves, p1max for various actuator forces. Design The valve components, spindle, seats and cone, are made of stainless steel. The valve body is made of nodular cast iron EN-GJS-400-15 with flanges drilled according to EN 1092-2. The connection thread for the actuator is G1B ISO 228. The valves are double-seated and designed for tight closure. The leakage rate is less than 0.5% of the full flow (according to VDI/VDE 2174). Function Reverse Acting Without an actuator being connected, the valve is held in a closed position using a spring. With pressure on the spindle, the valve opens. In connection with our actuators, the valves act as œcooling valves, i.e. they open at rising temperatures. The linear characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

G2F 2-way Control Valve (DN100-DN150)
8991
The Clorius G2F 2-way control valves (DN100…DN150) is designed for use in regulating high-pressure hot water, steam and heat transfer oil. The valves are used in conjunction with temperature or pressure differential regulators for controlling district or central heating plants, industrial processes or marine installations. Design The valve components “ spindle, seats and cone “ are made of stainless steel. The valve body is made of nodular cast iron EN-GJS-400-15 with flanges drilled according to EN 1092-2. The connection thread for the actuator is G1B ISO 228. The valves are double-seated. The leakage rate is less than 0.5% of the full flow (according to VDI/VDE 2174). Function Without the actuator being connected, the valve is held in an open position by means of a spring. With pressure on the spindle, the valve will close. In connection with our thermostats, pneumatic or electric actuators, the valves will close at rising temperatures. For cooling circuits, the valve can be used in conjunction with a reverse acting electric actuator. Alternatively, a reverse acting valve can be used with our self-acting thermostats. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

M2FR 2-way Control Valve (DN100-DN150)
9033
The Clorius type M2FR 2-way control valve (DN100-DN150) is mainly intended for control of cooling systems. The M2FR is used in conjunction with temperature or pressure differential regulators. As the reverse acting valves are held in a closed position by means of a built-in spring, the max. differential pressure, ΔpL, against which a valve can close depends on the spring and when opening the valve, the actuator has to overcome the spring force. Download datasheet to find the max. allowable values of ΔpL as well as the max. allowable inlet pressures for opening the valve, p1max for various actuator forces. Design The valve components – spindle, seats and cone – are made of stainless steel. The valve body is made of cast iron EN-GJL-250 with flanges drilled according to EN 1092-2. The connection thread for the actuator is G1B ISO 228. The valves are double-seated. The leakage rate is less than 0.5% of the full flow (according to VDI/VDE 2174). Reverse acting Without an actuator being connected, the valve is held in a closed position by means of a spring. With pressure on the spindle the valve opens. In connection with our thermostats, the valves act as œcooling valves, i.e. they open at rising temperatures. The linear characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

M2FR 2-way Control Valve
9037
The Clorius type M2FR 2-way control valve is mainly intended for the control of cooling systems. The M2FR is used in conjunction with temperature or pressure differential regulators. As the reverse acting valves are held in a closed position by means of a built-in spring, the max. differential pressure, ΔpL, against which a valve can close depends on the spring and when opening the valve, the actuator has to overcome the spring force. Download datasheet to find the max. allowable values of ΔpL as well as the max. allowable inlet pressures for opening the valve, p1max for various actuator forces. Design The valve components “ spindle, seats and cone “ are made of stainless steel. The valve body is made of cast iron EN-GJL-250 with flanges drilled according to EN 1092-2. The connection thread for the actuator is G1B ISO 228. The valves are double-seated. The leakage rate is less than 0.5% of the full flow (according to VDI/VDE 2174). Reverse acting Without an actuator being connected, the valve is held in a closed position by means of a spring. With pressure on the spindle the valve opens. In connection with our thermostats, the valves act as œcooling valves, i.e. they open at rising temperatures. The linear characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

M2F 2-way Control Valve
9041
The Clorius M2F double-seated two-way control valve is designed for regulating hot water, steam and hot oil systems. The M2F is installed combined with temperature- or pressure-differential regulators in control systems for heating to domestic premises, district- and group heating schemes, industrial processes or marine installations.
- USD