Filter Sort
close
1 - 3 of 3
TR22-B Resistance Thermometer

TR22-B Resistance Thermometer

2896

The WIKA TR22-B resistance thermometer is used for temperature measurement in sanitary applications. For an integration into the process, the patented thermowell model TW61 is directly fitted into a pipeline using orbital welding. The connection ends are smooth and prepared for orbital welding. The process connections meet the stringent requirements, in terms of materials and design, of hygienic measuring points. For easy calibration or maintenance, the sensor is removable without having to break into the process or disconnect the electrical connection. Thus hygiene risks can be minimised, and downtimes can be reduced. The spring-loaded measuring insert guarantees the contact between the sensor tip and the bottom of the thermowell and thus ensures a fast response time and high accuracy.
View Details
TR25 Resistance Thermometer

TR25 Resistance Thermometer

2899

This WIKA TR25 resistance thermometer is used in applications where a thermowell immersed into the process medium is not possible or not desired, particularly for piggable pipelines, highly viscous media and flow conditions with high shear forces. A wide variety of process connections is available so that these thermometers can be used for many different processes without any problems. 3- or 4-wire platinum measurement resistances in accuracy classes A and B per DIN EN 60751 serve as sensors. Analog or digital transmitters built into the connection head are able of making multiple output signals available, for example, 4 … 20 mA, HART® protocol, FOUNDATION„¢ fieldbus or PROFIBUS® PA.
View Details
TP18 850E Temperature Calibrator

TP18 850E Temperature Calibrator

4800

The SIKA TP18 850E basic temperature calibrator can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. The SIKA TP18850E basic temperature calibrator covers a broad spectrum of industries with diverse applications. The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern.
View Details
1 - 3 of 3