close
Categories
Filter By
Company
Temperature Range
- 0...50°C 3
- 0...80°C 1
- 0...160ºC 2
- 0...185°C 1
- 0...550°C 1
- 0...750°C 1
- 13...116°C 1
- 15...25°C 3
- 20...150°C 1
- 49...113°C 4
- 400...1300°C 1
- -5...50°C 2
- -10...0°C__0...100°C 1
- -10...50°C 2
- -10...60°C 5
- -10...80°C 1
- -10...100°C 3
- -10...200°C 1
- -20...60°C 2
- -20...70°C 1
- -20...760° 2
- -25...80°C 1
- -25...90°C 1
- -30...70°C 1
- -30...100°C 2
- -30...120°C 1
- -30...140°C 3
- -30...150°C 2
- -30...150°C__-50...250°C 1
- -30...250°C 1
- -35...165°C 9
- -40°100°C 1
- -40...70°C 1
- -40...80°C 2
- -40...85°C 1
- -40...120°C 1
- -40...125°C 1
- -40...250°C 1
- -40...450°C 1
- -40...1000°C 1
- -50°200°C 2
- -50...150°C 2
- -50...250°C 7
- -50...260°C 1
- -50...600°C 1
- -55...200°C 3
- -100...1000°C 1
- -196...500°C 1
- -196...600°C 9
- -200...600°C 1
- -200...650°C 1
- 5...50°C 1
- Max. 400°C 1
- RET...650°C 1
- RT...200°C 1
- RT...255°C 2
- RT...450°C 3
- RT...650°C 3
- RT...850°C 1
- Thick-film-on-ceramic 1
49...113°C - 0...160ºC
6 items

Duostats
2176
The Clorius Duostats are thermostats, type V, which via two sensing elements in a common hydraulic system act on one and the same control valve. Two basic types are available: Clorius V4.05- or Clorius V4.10 duostat, depending on the preferable proportional band PB, and the valve size. The sensing elements are two spiral sensors for the ventilation duct or two-rod sensors (a combination of one spiral sensor and one-rod sensor may be supplied in certain combinations). The effect, which the two sensing elements have on the adjustment, is proportional to the liquid volume of the individual sensors. Duostats are therefore available with varying proportions between the liquid volumes of the two sensors (sensor proportions) and in that way they can meet the requirements made by a number of different adjustment problems. As the adjustment result is a weighted average value of the temperatures of the two sensors, noï¬xed adjustment value can be indicated. Hence, Duostats are not equipped with a temperature scale, but with a marking for adjustment towards higher or lower temperatures, respectively.
- USD

V2 / V4 / V8 Self-Acting Thermostats
9143
The temperature controller, which consists of a thermostat and a valve, is used to control the temperature in central heating systems, district heating systems, industrial plants or industrial processes, and marine systems. The Clorius V2 / V4 / V8 Self-Acting Thermostats can be used to control cold or hot water, steam or oil in heating and cooling systems. Thermostat A thermostat consists of a sensor and a capillary tube, ï¬ filled with liquid, and an adjusting cylinder. The thermostat type designations and technical data are speciï¬ ed in ï¬ g. 2. With temperatures above 170ºC, a cooling unit must be ï¬ fitted between the valve and the thermostat – see ï¬ g. 1. The thermostat is self-acting and works on the principle of liquid expansion, it is sturdy in its design, and works with a large closing force – see ï¬ g. 2 Sensor The following sensor types are available : Rod sensor in copper or stainless steel and spiral sensor in copper with threaded connection according to ISO R7/1. Spiral sensor (copper only) with air duct flange. Rod/spiral sensor with steel flange DN 50, PN 40 and DN 50, PN 160. Sensor without connection. Usually used with capillary pack box for temperature control in tanks. Capillary Tube The capillary tube is made of copper, stainless steel, or PVC-coated copper but can also be delivered with flexible iron tube protection.
- USD

FJA Mixing or Diverting Filterstat
9265
The AMOT FJA temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for diverting or mixing applications. They are available in ¾ size. The FJA mixing or diverting filterstat is ideal for compressor application where a filtered and controlled fluid temperature is required. The FJA has a compact design and low installation cost, and a flexible spin-on filter manifold, allowing customers to use the filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD

FET Diverting Filterstat
9269
The AMOT FET temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for diverting applications. The FET diverting filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. The FET has a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD

FED Diverting Dual Filter Filterstat
9272
The AMOT FED temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for dual diverting applications. The FED diverting dual filter filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. They have a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD

FE Mixing Filterstat
9275
The AMOT FE temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for mixing applications. They are available in 1 ¼ and 1 ½ sizes and settings to fill a multitude of fluid temperature control requirements. The AMOT FE mixing filterstat has a compact design and low installation cost, and flexible spin-on filter manifold, allowing the customer to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD
1 - 6 of 6
1