Filter Sort
close
1 - 6 of 6
TR60-x Resistance Thermometer

TR60-x Resistance Thermometer

3230

The WIKA TR60-A outdoor resistance thermometer features a closed probe tube and is intended for damp or humid rooms and outdoor applications. For application in hazardous areas, intrinsically safe versions are available. Indoor resistance thermometer, model TR60-B The WIKA TR60-B is intended for dry rooms. The sensor tube around the sensor is perforated. As a result of this perforation, the sensor is in direct contact with the ambient air. This considerably improves the response time. The range of applications is enhanced by the addition of optional analogue or digital transmitters.
View Details
RLS-5000 Bilge Float Switch

RLS-5000 Bilge Float Switch

7973

The WIKA RLS-5000 bilge float switch is used for the monitoring of limit levels in shipbuilding (e.g. in bilge water tanks) and industrial applications. The robust stainless steel case and the durable marine cable outlet of the RLS-5000 bilge float switch protect the float system during high mechanical loading, e.g. due to flotsam such as sticks and pieces of wood, inside the stainless steel case of the RLS-5000, a permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contact built into the pipe. The triggering of the reed contact by the permanent magnet is contact-free and thus free from wear. The reed switch function is freely definable as normally open, normally closed or change-over contact. In the event of maintenance, the optionally available test device enables the manual triggering of the float by a movable wire bracket. With its optimised mechanical design and certification in accordance with the leading maritime standards, the RLS-5000 bilge float switch is particularly suitable for long-term and reliable use in shipbuilding applications.
View Details
FJA Mixing or Diverting Filterstat

FJA Mixing or Diverting Filterstat

9265

The AMOT FJA temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for diverting or mixing applications. They are available in ¾ size. The FJA mixing or diverting filterstat is ideal for compressor application where a filtered and controlled fluid temperature is required. The FJA has a compact design and low installation cost, and a flexible spin-on filter manifold, allowing customers to use the filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
View Details
FET Diverting Filterstat

FET Diverting Filterstat

9269

The AMOT FET temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for diverting applications. The FET diverting filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. The FET has a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
View Details
FED Diverting Dual Filter Filterstat

FED Diverting Dual Filter Filterstat

9272

The AMOT FED temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for dual diverting applications. The FED diverting dual filter filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. They have a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
View Details
FE Mixing Filterstat

FE Mixing Filterstat

9275

The AMOT FE temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for mixing applications. They are available in 1 ¼ and 1 ½ sizes and settings to fill a multitude of fluid temperature control requirements. The AMOT FE mixing filterstat has a compact design and low installation cost, and flexible spin-on filter manifold, allowing the customer to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
View Details
1 - 6 of 6
1