close
Categories
Filter By
Company
Block
Temperature Range
- 0...50°C 3
- 0...80°C 1
- 0...160ºC 2
- 0...185°C 1
- 0...550°C 1
- 0...750°C 1
- 13...116°C 1
- 15...25°C 3
- 20...150°C 1
- 49...113°C 4
- 400...1300°C 1
- -5...50°C 2
- -10...0°C__0...100°C 1
- -10...50°C 2
- -10...60°C 5
- -10...80°C 1
- -10...100°C 3
- -10...200°C 1
- -20...60°C 2
- -20...70°C 1
- -20...760° 2
- -25...80°C 1
- -25...90°C 1
- -30...70°C 1
- -30...100°C 2
- -30...120°C 1
- -30...140°C 3
- -30...150°C 2
- -30...150°C__-50...250°C 1
- -30...250°C 1
- -35...165°C 9
- -40°100°C 1
- -40...70°C 1
- -40...80°C 2
- -40...85°C 1
- -40...120°C 1
- -40...125°C 1
- -40...250°C 1
- -40...450°C 1
- -40...1000°C 1
- -50°200°C 2
- -50...150°C 2
- -50...250°C 7
- -50...260°C 1
- -50...600°C 1
- -55...200°C 3
- -100...1000°C 1
- -196...500°C 1
- -196...600°C 9
- -200...600°C 1
- -200...650°C 1
- 5...50°C 1
- Max. 400°C 1
- RET...650°C 1
- RT...200°C 1
- RT...255°C 2
- RT...450°C 3
- RT...650°C 3
- RT...850°C 1
- Thick-film-on-ceramic 1
0...160ºC - -55...200°C
5 items

Duostats
2176
The Clorius Duostats are thermostats, type V, which via two sensing elements in a common hydraulic system act on one and the same control valve. Two basic types are available: Clorius V4.05- or Clorius V4.10 duostat, depending on the preferable proportional band PB, and the valve size. The sensing elements are two spiral sensors for the ventilation duct or two-rod sensors (a combination of one spiral sensor and one-rod sensor may be supplied in certain combinations). The effect, which the two sensing elements have on the adjustment, is proportional to the liquid volume of the individual sensors. Duostats are therefore available with varying proportions between the liquid volumes of the two sensors (sensor proportions) and in that way they can meet the requirements made by a number of different adjustment problems. As the adjustment result is a weighted average value of the temperatures of the two sensors, noï¬xed adjustment value can be indicated. Hence, Duostats are not equipped with a temperature scale, but with a marking for adjustment towards higher or lower temperatures, respectively.
- USD

TP37 200E.2 Temperature Calibrator
2333
The SIKA TP37 200E.2 temperature calibrator can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. The SIKA TP37 200E.2 temperature calibrator covers a broad spectrum of industries with diverse applications. The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and width can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern.
- USD

TP17 200 Temperature Calibrator
4776
The SIKA TP17 200 basic temperature calibrator can be used everywhere, including on-site in workshops, test and measurement rooms as well as laboratories. The SIKA TP basic series covers a broad spectrum of industries with diverse applications. The optimum thermal coupling from the block to test item is achieved with the right adapter sleeve. Ideally, the internal diameter of the jacket is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern.
- USD

TP17 200S Temperature Calibrator
4815
The SIKA TP17 200S temperature calibrator can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. The SIKA TP17200S temperature calibrator covers a broad spectrum of industries with diverse applications. The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and width can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern.
- USD

V2 / V4 / V8 Self-Acting Thermostats
9143
The temperature controller, which consists of a thermostat and a valve, is used to control the temperature in central heating systems, district heating systems, industrial plants or industrial processes, and marine systems. The Clorius V2 / V4 / V8 Self-Acting Thermostats can be used to control cold or hot water, steam or oil in heating and cooling systems. Thermostat A thermostat consists of a sensor and a capillary tube, ï¬ filled with liquid, and an adjusting cylinder. The thermostat type designations and technical data are speciï¬ ed in ï¬ g. 2. With temperatures above 170ºC, a cooling unit must be ï¬ fitted between the valve and the thermostat – see ï¬ g. 1. The thermostat is self-acting and works on the principle of liquid expansion, it is sturdy in its design, and works with a large closing force – see ï¬ g. 2 Sensor The following sensor types are available : Rod sensor in copper or stainless steel and spiral sensor in copper with threaded connection according to ISO R7/1. Spiral sensor (copper only) with air duct flange. Rod/spiral sensor with steel flange DN 50, PN 40 and DN 50, PN 160. Sensor without connection. Usually used with capillary pack box for temperature control in tanks. Capillary Tube The capillary tube is made of copper, stainless steel, or PVC-coated copper but can also be delivered with flexible iron tube protection.
- USD
1 - 5 of 5
1