Filter Sort
close
1 - 5 of 5
TR60-x Resistance Thermometer

TR60-x Resistance Thermometer

3230

The WIKA TR60-A outdoor resistance thermometer features a closed probe tube and is intended for damp or humid rooms and outdoor applications. For application in hazardous areas, intrinsically safe versions are available. Indoor resistance thermometer, model TR60-B The WIKA TR60-B is intended for dry rooms. The sensor tube around the sensor is perforated. As a result of this perforation, the sensor is in direct contact with the ambient air. This considerably improves the response time. The range of applications is enhanced by the addition of optional analogue or digital transmitters.
View Details
TP17 450 Temperature Calibrator

TP17 450 Temperature Calibrator

4791

The SIKA TP17 450 basic temperature calibrator can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. The SIKA TP17450 temperature calibrator covers a broad spectrum of industries with diverse applications. The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and diameter can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern.
View Details
TP17 450S Temperature Calibrator

TP17 450S Temperature Calibrator

4827

The SIKA TP17 450S solid temperature calibrator can be used everywhere, including on site in workshops, test and measurement rooms as well as laboratories. The SIKA TP TP17 450S solid temperature calibrator covers a broad spectrum of industries with diverse applications. The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and width can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern. Black body function A patented infrared calibration sleeve is used to calibrate IR pyrometers or thermal imaging cameras. The special surface structure and the asymmetrical shapes create a žcavity radiatorœ with an emission factor of 0.9994, prevent the reflection of interference radiation and emit the required temperature in an ideal form. The pyrometer is simply held at the specified distance above the measurement opening, thereby forming the desired measurement area on the bottom for the calibration to be performed. A support base can be fitted directly on the unit.
View Details
TP37 450E.2 Temperature Calibrator

TP37 450E.2 Temperature Calibrator

4850

The SIKA TP37 450E.2 temperature calibrator can be used everywhere, including on-site in workshops, test and measurement rooms as well as laboratories. The SIKA TP37 450E.2 temperature calibrator covers a broad spectrum of industries with diverse applications. The optimum thermal coupling from the block to test item is achieved with the correct adapter sleeve. Ideally, the internal diameter of the sleeve is 0.5 mm larger than the outer diameter of the test item. With the aid of the adapter sleeve, straight temperature sensors of virtually any length and width can be calibrated. The dry block covers the entire temperature range without the need to change the calibration medium. Viscosity, flashpoints or outgassing are of no concern. The TP TP37 450E.2 premium temperature calibrator series stands for optimum performance and outstanding ease of use. With the help of the self-explanatory menu structure, all the necessary entries can be made quickly and easily. The block and set temperature, as well as the difference and the variance of the stability, are displayed on the touch display. The block temperature can be set to precisely 0.001 °C. The entire thermosensitive range of temperature sensors is covered. The calibrators work in a temperature range up to 650 °C, while offering excellent stability and accuracy. By combining the dry block design with an input for an external reference sensor, SIKA calibrators have the same accuracy as laboratory calibrators while maintaining the speed and portability of a dry block. The temperature sensor under test can be connected and analysed directly. Additional instruments are not required. Together with a PC as a standalone calibration system, the result is an extremely quick test cycle.
View Details
RLS-5000 Bilge Float Switch

RLS-5000 Bilge Float Switch

7973

The WIKA RLS-5000 bilge float switch is used for the monitoring of limit levels in shipbuilding (e.g. in bilge water tanks) and industrial applications. The robust stainless steel case and the durable marine cable outlet of the RLS-5000 bilge float switch protect the float system during high mechanical loading, e.g. due to flotsam such as sticks and pieces of wood, inside the stainless steel case of the RLS-5000, a permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contact built into the pipe. The triggering of the reed contact by the permanent magnet is contact-free and thus free from wear. The reed switch function is freely definable as normally open, normally closed or change-over contact. In the event of maintenance, the optionally available test device enables the manual triggering of the float by a movable wire bracket. With its optimised mechanical design and certification in accordance with the leading maritime standards, the RLS-5000 bilge float switch is particularly suitable for long-term and reliable use in shipbuilding applications.
View Details
1 - 5 of 5
1