Filter Sort
close
1 - 4 of 4
TR21-B Resistance Thermometer

TR21-B Resistance Thermometer

2887

The WIKA TR21-B resistance thermometer provides temperature measurement in sanitary applications and can be used for the measurement of liquid and gaseous media in the range of -30 … 150°C (-22 … +302 °F). For application in hazardous areas, intrinsically safe versions are available. To integrate it into the process, the WIKA TW61 thermowell is directly orbitally welded into a pipeline. The connection ends are straight and prepared for orbital welding. The process connections meet the stringent requirements, in terms of materials and design, of hygienic measuring points. All electrical components are protected against moisture (IP67 or IP69K). The resistance thermometer is available with direct sensor output or integrated transmitter, which can be configured individually via the PC configuration software WIKAsoft-TT. Measuring range, damping, error signalling per NAMUR NE43 and TAG no. can be adjusted. For easy calibration or maintenance, the sensor is removable without having to break into the process or disconnect the electrical connection. Thus hygiene risks can be minimised, and downtimes can be reduced. The spring loading, integrated into the union nut, guarantees the contact between the sensor tip and the bottom of the thermowell and thus ensures a short response time and lasting high accuracy. Insertion length, process connection, sensor and connection method can each be selected for the respective application within the order information. The electrical connection is made via an M12 x 1 circular connector. For applications requiring the sterilisation of the instrument in autoclaves, an especially temperature-resistant instrument version is available.
View Details
TR21-C Resistance Thermometer

TR21-C Resistance Thermometer

2890

The WIKA TR21-C resistance thermometer provides temperature measurement in sanitary applications and can be used for the measurement of liquid and gaseous media in the range of -30 … 250°C (-22 … 482°F). For application in hazardous areas, intrinsically safe versions are available. These thermometers are fitted with process connections that meet the stringent requirements, in terms of materials and design, of hygienic measuring points. All electrical components are protected against moisture (IP67 or IP69K). The resistance thermometer is available with direct sensor output or integrated transmitter, which can be configured individually via the PC configuration software WIKAsoft-TT. Measuring range, damping, fault signal per NAMUR NE43 and TAG no. can be adjusted. The welded junction between the thermowell and the flange makes the use of a sealing as additional material in those areas redundant which are in contact with the product. Through the compact design, this resistance thermometer is designed specifically for operation in applications with limited mounting space. Insertion length, process connection, sensor and connection method can each be selected for the respective application within the order information. The electrical connection is made with an M12 x 1 circular connector. For applications requiring the sterilisation of the instrument in autoclaves, an especially temperature-resistant instrument version is available.
View Details
TR60-x Resistance Thermometer

TR60-x Resistance Thermometer

3230

The WIKA TR60-A outdoor resistance thermometer features a closed probe tube and is intended for damp or humid rooms and outdoor applications. For application in hazardous areas, intrinsically safe versions are available. Indoor resistance thermometer, model TR60-B The WIKA TR60-B is intended for dry rooms. The sensor tube around the sensor is perforated. As a result of this perforation, the sensor is in direct contact with the ambient air. This considerably improves the response time. The range of applications is enhanced by the addition of optional analogue or digital transmitters.
View Details
RLS-5000 Bilge Float Switch

RLS-5000 Bilge Float Switch

7973

The WIKA RLS-5000 bilge float switch is used for the monitoring of limit levels in shipbuilding (e.g. in bilge water tanks) and industrial applications. The robust stainless steel case and the durable marine cable outlet of the RLS-5000 bilge float switch protect the float system during high mechanical loading, e.g. due to flotsam such as sticks and pieces of wood, inside the stainless steel case of the RLS-5000, a permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contact built into the pipe. The triggering of the reed contact by the permanent magnet is contact-free and thus free from wear. The reed switch function is freely definable as normally open, normally closed or change-over contact. In the event of maintenance, the optionally available test device enables the manual triggering of the float by a movable wire bracket. With its optimised mechanical design and certification in accordance with the leading maritime standards, the RLS-5000 bilge float switch is particularly suitable for long-term and reliable use in shipbuilding applications.
View Details
1 - 4 of 4