close
Filter By
Company
Ambient Temperature
Approvals
Connection Type
Material Spec
Pressure Range
Temperature Range
- 0...50°C 3
- 0...80°C 1
- 0...160ºC 2
- 0...185°C 1
- 0...550°C 1
- 0...750°C 1
- 13...116°C 1
- 15...25°C 3
- 20...150°C 1
- 49...113°C 4
- 400...1300°C 1
- -5...50°C 2
- -10...0°C__0...100°C 1
- -10...50°C 2
- -10...60°C 5
- -10...80°C 1
- -10...100°C 3
- -10...200°C 1
- -20...60°C 2
- -20...70°C 1
- -20...760° 2
- -25...80°C 1
- -25...90°C 1
- -30...70°C 1
- -30...100°C 2
- -30...120°C 1
- -30...140°C 3
- -30...150°C 2
- -30...150°C__-50...250°C 1
- -30...250°C 1
- -35...165°C 9
- -40°100°C 1
- -40...70°C 1
- -40...80°C 2
- -40...85°C 1
- -40...120°C 1
- -40...125°C 1
- -40...250°C 1
- -40...450°C 1
- -40...1000°C 1
- -50°200°C 2
- -50...150°C 2
- -50...250°C 7
- -50...260°C 1
- -50...600°C 1
- -55...200°C 3
- -100...1000°C 1
- -196...500°C 1
- -196...600°C 9
- -200...600°C 1
- -200...650°C 1
- 5...50°C 1
- Max. 400°C 1
- RET...650°C 1
- RT...200°C 1
- RT...255°C 2
- RT...450°C 3
- RT...650°C 3
- RT...850°C 1
- Thick-film-on-ceramic 1
-10...200°C - -30...150°C
3 items

TR21-B Resistance Thermometer
2887
The WIKA TR21-B resistance thermometer provides temperature measurement in sanitary applications and can be used for the measurement of liquid and gaseous media in the range of -30 … 150°C (-22 … +302 °F). For application in hazardous areas, intrinsically safe versions are available. To integrate it into the process, the WIKA TW61 thermowell is directly orbitally welded into a pipeline. The connection ends are straight and prepared for orbital welding. The process connections meet the stringent requirements, in terms of materials and design, of hygienic measuring points. All electrical components are protected against moisture (IP67 or IP69K). The resistance thermometer is available with direct sensor output or integrated transmitter, which can be configured individually via the PC configuration software WIKAsoft-TT. Measuring range, damping, error signalling per NAMUR NE43 and TAG no. can be adjusted. For easy calibration or maintenance, the sensor is removable without having to break into the process or disconnect the electrical connection. Thus hygiene risks can be minimised, and downtimes can be reduced. The spring loading, integrated into the union nut, guarantees the contact between the sensor tip and the bottom of the thermowell and thus ensures a short response time and lasting high accuracy. Insertion length, process connection, sensor and connection method can each be selected for the respective application within the order information. The electrical connection is made via an M12 x 1 circular connector. For applications requiring the sterilisation of the instrument in autoclaves, an especially temperature-resistant instrument version is available.
- USD

TR21-C Resistance Thermometer
2890
The WIKA TR21-C resistance thermometer provides temperature measurement in sanitary applications and can be used for the measurement of liquid and gaseous media in the range of -30 … 250°C (-22 … 482°F). For application in hazardous areas, intrinsically safe versions are available. These thermometers are fitted with process connections that meet the stringent requirements, in terms of materials and design, of hygienic measuring points. All electrical components are protected against moisture (IP67 or IP69K). The resistance thermometer is available with direct sensor output or integrated transmitter, which can be configured individually via the PC configuration software WIKAsoft-TT. Measuring range, damping, fault signal per NAMUR NE43 and TAG no. can be adjusted. The welded junction between the thermowell and the flange makes the use of a sealing as additional material in those areas redundant which are in contact with the product. Through the compact design, this resistance thermometer is designed specifically for operation in applications with limited mounting space. Insertion length, process connection, sensor and connection method can each be selected for the respective application within the order information. The electrical connection is made with an M12 x 1 circular connector. For applications requiring the sterilisation of the instrument in autoclaves, an especially temperature-resistant instrument version is available.
- USD

KPS Pressure Switch & Thermostat
5306
The Danfoss KPS thermostat and pressure switch series consists of a series of pressure and temperature controlled switches. In the Danfoss KPS series, special attention has been given to meeting demands for a high level of enclosure, robust and compact construction, and resistance to shock and vibration. For the Danfoss KPS pressure switches, the position of the contacts depends on the pressure in the inlet connection and the set scale value. For KPS thermostats, the position of the contacts depends on the temperature of the sensor and the fixed scale value. The series covers most outdoor and indoor application requirements and is suitable for use in monitoring alarm and control systems in factories, diesel plants, compressors, power stations, and board ships. Available types: Danfoss KPS 76 Pressure Switch and Thermostat Danfoss KPS 77 Pressure Switch and Thermostat Danfoss KPS 79 Pressure Switch and Thermostat Danfoss KPS 80 Pressure Switch and Thermostat Danfoss KPS 81 Pressure Switch and Thermostat Danfoss KPS 83 Pressure Switch and Thermostat
- USD
1 - 3 of 3
1