Filter Sort
close
1 - 5 of 5
ER2000 Electronic Controller

ER2000 Electronic Controller

2183

The Clorius ER 2000 electronic controller is used for constant temperature control. It is suitable for all heating and cooling control systems. The controller is primarily intended for marine installations and other industrial applications – such as cooling water and lubricating oil installations, flow temperature control etc. Design The ER 2000 controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has three keys – two for scrolling or changing values and an enter key. Two digital displays show the process variable and the setpoint. 3 LEDs indicate actuator opens, actuator closes and alarm. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP It can operate either as a three-position or as a two-position controller or analogue (4-20 mA) controller and has an adjustable proportional band, integral action time and derivative action time. Function The temperature input comes via a Pt 100 sensor with a single sensing element. The measured value of the controlled variable is compared with the setpoint value and adjusted via a PI or a PID control structure. The ER 2000 can act as either a heating controller, the actuator closes at rising temperature, or as a cooling controller, the actuator opens at rising temperature. The ER 2000 permits direct reading of the actual temperature value (PV), and it is secured from failure in the measuring circuit, i.e. the controller can be set to give either a closing, an opening, or remain in current position command in case of sensor short circuit or sensor break. The error message Err appears in the LED display PV.
View Details
M132 Fixed Mount Thermal Camera

M132 Fixed Mount Thermal Camera

7481

The FLIR M132 fixed mount thermal camera is a compact adjustable tilt camera and is FLIR's smallest, most affordable installed marine camera. Featuring a resolution of 320 x 240, the M132 thermal camera improves safety by revealing vessels and obstacles at night. The FLIR M132 fixed mount thermal camera offers an adjustable tilt for optimal positioning while underway. Combine the FLIR M132 with a Raymarine Axiom MFD and take advantage of FLIR's ClearCruise„¢ intelligent thermal analytics. ClearCruise„¢ provides audible and visual alerts when non-water objects“such as boats, obstacles, or navigation markers“appear in the scene. This enhances boaters' overall situational awareness, both day and night. Installation Note: ClearCruise„¢ features are only available on conventional ball-up installations. ClearCruise„¢ is not available on ball-down installations.
View Details
ER2000-P Electric Controller

ER2000-P Electric Controller

9171

The Clorius ER 2000-P controller is used for constant pressure control. It is suitable for all heating and cooling control systems. The controller is primarily intended for marine installations and other industrial applications. Design The ER 2000-P controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has three keys – two for scrolling or changing values and an enter key. Two digital displays show the process variable and the setpoint. 3 LEDs indicate actuator opens, actuator closes and alarm. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP It can operate either as a three-position or as a two-position controller or analogue controller (4-20 mA) and has an adjustable proportional band, integral action time and derivative action time. Function The pressure input comes via a 4-20 mA signal. The measured value of the controlled variable is compared with the setpoint value and adjusted via a PI or a PID control structure. The ER 2000-P permits direct reading of the actual temperature value (PV) and it is secured from failure in the measuring circuit, i.e. the controller can be set to give either a closing, an opening or remain in current position command in case of sensor short circuit or sensor break. The error message Err appears in the LED display PV.
View Details
ER3000 Electric Controller

ER3000 Electric Controller

9175

The Clorius ER 3000e electric controller is used for constant temperature control. It is specially designed for large engine jacket cooling water systems where conventional single loop controllers cannot maintain a constant and precise temperature. The ER3000 controller operates with TWO sensor inputs. One Pt 100 sensor is placed at the outlet from the engine and one Pt 100 sensor with a built-in 4-20 mA transmitter is placed at the inlet to the engine. The measured values of the controlled variables are compared with the setpoint value and adjusted via a PI or a PID control structure. Design The ER 3000 controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has four keys – two for scrolling or changing values, an enter key and a key for choosing manual or automatic control. Two digital displays show the process variable and the setpoint. 7 LEDs indicate alarm, the actuator opens, actuator closes, slave control, setpoint raising/lowering and manual mode. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP The 3 alarm settings include an alarm in case of a sensor fault. It can operate either as a three-position or as a two-position controller and has adjustable proportional band, integral action time and derivative action time.
View Details
XT Air Intake Shut Off Valve

XT Air Intake Shut Off Valve

9304

The AMOT XT air intake shut off valve uses the latest technology to shut down a runaway diesel by positively choking off engine intake air. The AMOT XT shut off valve operates as part of a fully automatic overspeed shutdown system when paired with our Revguard 2 speed switch and activation kit. The XT solenoid activation rapidly closes the valve's butterfly disc, which shuts off intake airflow into the engine. The XT XT air intake shut off valve is available in a variety of sizes to fit your specific applications. It is manufactured from corrosion-resistant, RoHS compliant material that offers toughness under extreme temperatures and resistance to corrosive environments. AMOT's valves are tested to strict OEM standards for shock, corrosion, vibration, and life cycle.
View Details
1 - 5 of 5
1