close
Categories
Filter By
Company
Connection Type
Material Spec
Nominal Pressure
Size
- 1.5''...8.0'' 2
- 2'' pipe 1
- 2.8''...7.0'' valve size 1
- 4''__6'' 2
- 7''__ˆ… 6'' 2
- 88.90 mm x 205 mm 1
- 96 x 96 x 135 mm 3
- 110 x 32 mm 1
- 132 x 82 x 34 mm 5
- 160 mm x 62 mm 1
- 229.3 mm__ˆ… 160 mm 1
- 229.3 mm__ˆ…160 mm 1
- 235 x 75 mm 1
- 270x90x35 mm 1
- 397.5 mm__ˆ… 273 mm 1
- DN15...DN50 1
- DN15__DN20 2
- DN15__DN20__DN25...DN50 1
- DN20...DN65 2
- DN20...DN80 1
- DN20..DN32 1
- DN25 1
- DN25__DN32__DN40__DN50__DN65 1
- DN32...DN40 3
- DN40...DN200 1
- DN50 1
- DN50...DN100 1
- DN50...DN350 1
- DN50...DN400 1
- DN65...DN150 2
- DN65...DN800 2
- DN80...DN150 1
- DN80...DN300 1
- DN90...DN200 1
- DN100...DN600 2
- DN100...DN800 1
- DN100__DN125__DN150 2
- DN100__DN125__DN150__DN20...DN80 1
- DN100__DN125__DN150__DN80 2
DN20...DN80 - DN65...DN150
3 items

L2FR (Reverse Acting) 2-way Control Valve
8964
The Clorius L2FR (reverse acting) 2-way control valves with 2 single seats are designed for regulating low, medium, high-pressure hot water and hot and cold seawater. The L2FR reverse acting gun metal valve is installed combined with Clorius self-acting thermostats, pressure differential regulators or electric valve actuators for regulation in central heating plants, industrial plants, industrial processes or marine installations – especially in control systems for cooling as the reverse acting valve is held in a closed position using a built-in spring, the max. differential pressure, which a valve can close, depends on the spring, and when opening the valve, the actuator has to overcome the spring force.
- USD

L2F 2-way Control Valve
8967
The Clorius L2F 2-way control valve is designed for regulating hot water – and cold and hot seawater. The valve is used in connection with one of Clorius temperature regulators in control systems for industrial processes or marine installations. Design The valve components – valve body, seats, cone and spindle – are made of sea water-resistant materials with connection flanges drilled according to DIN 86021. The connection thread for the actuator is G1B. Function Without the actuator being connected, the valve is held in an open position by means of a spring. With pressure on the spindle, the valve will close. In connection with our thermostats or electronic actuators, the valves will close at rising temperatures. The linear characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

G2F 2-way Control Valve
8995
The Clorius G2F 2-way control valve is designed for regulating hot water, steam and hot oil systems. The double-seated G2F linear valve is used in installations where the system pressure necessitates a closing force greater than available in the actuator programme for a single-seated valve. The valve is used in conjunction with Clorius temperature or pressure differential regulators for controlling industrial processes, district or central heating plants or marine installations. Design The valve components – spindle, seats and cone – are made of stainless steel. The valve body is made of nodular cast iron EN-GJS-400-15 with flanges drilled according to EN 1092-2. The thread for the actuator connection is G1B ISO 228. The valves are double-seated. The leakage rate is less than 0.5% of the full flow (according to VDI/VDE 2174). Function Without the actuator being connected, the valve is held in an open position by means of a spring. With pressure on the spindle, the valve will close. In connection with our thermostats, pneumatic or electric actuators, the valves will close at rising temperatures. For cooling circuits, the valve can be used in conjunction with a reverse acting electric actuator. Alternatively, a reverse acting valve can be used with our self-acting thermostats. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD
1 - 3 of 3
1