close
Categories
Filter By
Company
Connection Type
Nominal Pressure
Size
- 1.5''...8.0'' 2
- 2'' pipe 1
- 2.8''...7.0'' valve size 1
- 4''__6'' 2
- 7''__ˆ… 6'' 2
- 88.90 mm x 205 mm 1
- 96 x 96 x 135 mm 3
- 110 x 32 mm 1
- 132 x 82 x 34 mm 5
- 160 mm x 62 mm 1
- 229.3 mm__ˆ… 160 mm 1
- 229.3 mm__ˆ…160 mm 1
- 235 x 75 mm 1
- 270x90x35 mm 1
- 397.5 mm__ˆ… 273 mm 1
- DN15...DN50 1
- DN15__DN20 2
- DN15__DN20__DN25...DN50 1
- DN20...DN65 2
- DN20...DN80 1
- DN20..DN32 1
- DN25 1
- DN25__DN32__DN40__DN50__DN65 1
- DN32...DN40 3
- DN40...DN200 1
- DN50 1
- DN50...DN100 1
- DN50...DN350 1
- DN50...DN400 1
- DN65...DN150 2
- DN65...DN800 2
- DN80...DN150 1
- DN80...DN300 1
- DN90...DN200 1
- DN100...DN600 2
- DN100...DN800 1
- DN100__DN125__DN150 2
- DN100__DN125__DN150__DN20...DN80 1
- DN100__DN125__DN150__DN80 2
Temperature Range
DN15...DN50 - DN32...DN40
4 items

H1F 2-way Control Valve
9029
The Clorius H1F 2-way control valve is designed for regulating hot water, steam and hot oil systems. The H1F control valve is used in conjunction with our temperature or pressure differential regulators for controlling industrial processes, district or central heating plants or marine installations. Design The H1F valve components – spindle, seat and cone – are made of stainless steel. The valve body is made of cast steel GP240GH (GS-C25) with flanges drilled according to EN 1092-1 or ANSI B16.5 Class 150. The thread for the actuator connection is G1B ISO 228. The valves are single-seated. The leakage rate is less than 0.05% of the full flow (according to VDI/VDE 2174). Function Without the actuator being connected, the valve is held in an open position by means of a spring. With pressure on the spindle, the valve will close. In connection with our thermostats, electric or pneumatic actuators, the valves will close at rising temperatures. For cooling circuits, the valve can be used in conjunction with a reverse acting electric actuator. Alternatively, a reverse acting valve can be used with our self-acting thermostats. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

FET Diverting Filterstat
9269
The AMOT FET temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for diverting applications. The FET diverting filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. The FET has a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD

FED Diverting Dual Filter Filterstat
9272
The AMOT FED temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for dual diverting applications. The FED diverting dual filter filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. They have a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD

FE Mixing Filterstat
9275
The AMOT FE temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for mixing applications. They are available in 1 ¼ and 1 ½ sizes and settings to fill a multitude of fluid temperature control requirements. The AMOT FE mixing filterstat has a compact design and low installation cost, and flexible spin-on filter manifold, allowing the customer to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD
1 - 4 of 4
1