close
Categories
Filter By
Company
Connection Type
Nominal Pressure
Size
- 1.5''...8.0'' 2
- 2'' pipe 1
- 2.8''...7.0'' valve size 1
- 4''__6'' 2
- 7''__ˆ… 6'' 2
- 88.90 mm x 205 mm 1
- 96 x 96 x 135 mm 3
- 110 x 32 mm 1
- 132 x 82 x 34 mm 5
- 160 mm x 62 mm 1
- 229.3 mm__ˆ… 160 mm 1
- 229.3 mm__ˆ…160 mm 1
- 235 x 75 mm 1
- 270x90x35 mm 1
- 397.5 mm__ˆ… 273 mm 1
- DN15...DN50 1
- DN15__DN20 2
- DN15__DN20__DN25...DN50 1
- DN20...DN65 2
- DN20...DN80 1
- DN20..DN32 1
- DN25 1
- DN25__DN32__DN40__DN50__DN65 1
- DN32...DN40 3
- DN40...DN200 1
- DN50 1
- DN50...DN100 1
- DN50...DN350 1
- DN50...DN400 1
- DN65...DN150 2
- DN65...DN800 2
- DN80...DN150 1
- DN80...DN300 1
- DN90...DN200 1
- DN100...DN600 2
- DN100...DN800 1
- DN100__DN125__DN150 2
- DN100__DN125__DN150__DN20...DN80 1
- DN100__DN125__DN150__DN80 2
Temperature Range
DN100...DN600, DN15...DN50, DN20...DN80 - DN32...DN40
7 items

G2F 2-way Control Valve
8995
The Clorius G2F 2-way control valve is designed for regulating hot water, steam and hot oil systems. The double-seated G2F linear valve is used in installations where the system pressure necessitates a closing force greater than available in the actuator programme for a single-seated valve. The valve is used in conjunction with Clorius temperature or pressure differential regulators for controlling industrial processes, district or central heating plants or marine installations. Design The valve components – spindle, seats and cone – are made of stainless steel. The valve body is made of nodular cast iron EN-GJS-400-15 with flanges drilled according to EN 1092-2. The thread for the actuator connection is G1B ISO 228. The valves are double-seated. The leakage rate is less than 0.5% of the full flow (according to VDI/VDE 2174). Function Without the actuator being connected, the valve is held in an open position by means of a spring. With pressure on the spindle, the valve will close. In connection with our thermostats, pneumatic or electric actuators, the valves will close at rising temperatures. For cooling circuits, the valve can be used in conjunction with a reverse acting electric actuator. Alternatively, a reverse acting valve can be used with our self-acting thermostats. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

H1F 2-way Control Valve
9029
The Clorius H1F 2-way control valve is designed for regulating hot water, steam and hot oil systems. The H1F control valve is used in conjunction with our temperature or pressure differential regulators for controlling industrial processes, district or central heating plants or marine installations. Design The H1F valve components – spindle, seat and cone – are made of stainless steel. The valve body is made of cast steel GP240GH (GS-C25) with flanges drilled according to EN 1092-1 or ANSI B16.5 Class 150. The thread for the actuator connection is G1B ISO 228. The valves are single-seated. The leakage rate is less than 0.05% of the full flow (according to VDI/VDE 2174). Function Without the actuator being connected, the valve is held in an open position by means of a spring. With pressure on the spindle, the valve will close. In connection with our thermostats, electric or pneumatic actuators, the valves will close at rising temperatures. For cooling circuits, the valve can be used in conjunction with a reverse acting electric actuator. Alternatively, a reverse acting valve can be used with our self-acting thermostats. The quadratic characteristic will not cease until the flow has dropped below 4% of the full flow.
- USD

G2FM-T 2-way Control Valve
9058
The CLorius G2FM-T control valve is a two-way control valve with a blocked port making a two-way control valve. The slide for a quarter-turn operation designed for regulating freshwater, lubricating oil and other liquid media. The G2FM-T valve is designed for use in conjunction with industrial processes, district heating and marine installations with large water or lubricating oil quantities. The valves are designed for use in conjunction with valve motor type CAR with handle for manual operation or for use in conjunction with a pneumatic actuator. Design The valve body and the valve slide are made of nodular cast iron. The valve flanges are drilled according to EN 1092-2 or ANSI Class 150. Function The slide is firmly connected with the motor spindle. When the slide is in the one extreme position by turning the spindle, connection A-AB is kept fully open. In the other extreme position connection, the valve is fully closed. In the intermediate positions, the opening degrees change proportionally. The valve has a small tolerance between body and slide. To minimize the leakage an O-ring is mounted in a groove on the slide.
- USD

S2FM-T 2-way Control Valve
9062
The Clorius S2FM-T control valve is a three-way control valve with a blocked port making a two-way control valve. The slide for a quarter-turn operation designed for regulating freshwater, lubricating oil and other liquid media. The S2FM-T control valve is designed for use in conjunction with industrial processes, district heating and marine installations with large water or lubricating oil quantities. The valves are designed for use in conjunction with valve motor type CAR with handle for manual operation or for use in conjunction with a pneumatic actuator. Design The valve body and the valve slide are made of stainless steel AISI316. The valve flanges are drilled according to EN 1092-2. Optional: ANSI, JIS and Grooved Victalic Joints. Function The slide is firmly connected with the motor spindle. When the slide is in the one extreme position by turning the spindle, connection A-AB is kept fully open. In the other extreme position connection, the valve is fully closed. In the intermediate positions, the opening degrees change proportionally. The valve has a small tolerance between the body and slide. To minimize the leakage an O-ring is mounted in a groove on the slide.
- USD

FET Diverting Filterstat
9269
The AMOT FET temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for diverting applications. The FET diverting filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. The FET has a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD

FED Diverting Dual Filter Filterstat
9272
The AMOT FED temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for dual diverting applications. The FED diverting dual filter filterstat is available in 1 ¼ and 1 ½ sizes and settings to fill many fluid temperature control requirements. They have a compact design and low installation cost, and flexible spin-on filter manifold, allowing customers to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD

FE Mixing Filterstat
9275
The AMOT FE temperature and filter manifolds are fully automatic, 3-way fluid temperature controllers for mixing applications. They are available in 1 ¼ and 1 ½ sizes and settings to fill a multitude of fluid temperature control requirements. The AMOT FE mixing filterstat has a compact design and low installation cost, and flexible spin-on filter manifold, allowing the customer to use filter size of their choice. As with other AMOT thermostatic valves, temperature and filter manifold uses fully enclosed, factory-set temperature element assemblies which provide tamper-proof operation. It is field replaceable and is available with temperature settings from 49°C to 113°C (120°F to 235°F). To change a valve setting, it is necessary to exchange the temperature element assembly.
- USD
1 - 7 of 7
1