close
Filter By
Company
Accuracy
Ambient Temperature
Approvals
Connection Type
Medium Temperature
Nominal Diameter
Pressure Range
- 0...0.6 bar 1
- 0...0.6 bar__0...40 bar 5
- 0...0.6 bar__0...40 bar__PN 16/40 or Class 150/300 1
- 0...1.000 bar 1
- 0...1.000 mbar 1
- 0...1 bar__0...10 bar 1
- 0...1 bar__0...25 bar 1
- 0...1 bar__0...40 bar 1
- 0...10.000 bar 1
- 0...10 bar__0...600 bar 1
- 0...16 bar 1
- 0...25 bar 3
- 0...40 bar 1
- 0...60 bar 4
- 0...100 bar 1
- 0...250 bar 1
- 0...400 bar 2
- 0...600 bar 9
- 0...700 bar 3
- 0...1000 bar 2
- 0...1600 bar 1
- 2...20 bar 1
- 10 bar 1
- 10 bar__6 bar__8 bar 6
- 20 bar 1
- 25 bar__40 bar 2
- 25 mbar 1
- 40...400 mbar 1
- 100 bar 1
- 250 bar 1
- 300 bar 1
- 350...400 bar 2
- -0.2...21 bar 1
- -0.2...400 bar 1
- -0.95...40 bar 1
- -0.95...60 bar 1
- -1...1 bar__0...2.000 bar 1
- -1...1 bar__0...2500 bar 1
- -1...2 bar__0...1000 bar 1
- -1...3 bar__0...700 bar 1
- -1...3 bar__0...1000 bar 1
- -1...10 bar__0...1000 bar 1
- -1...18 bar 1
- -1...60 bar 1
- -1...210 bar 2
- -1...250 bar 1
- -1...400 bar 1
- -1...1000 bar 1
- Corresponding to flange specification 1
- From 400 mbar depending on diameter of diaphragm 1
- PN 10 10
- PN 10 €“ 100; Class 150 - 600 1
- PN 16 8
- PN 25 5
- PN 50 2
Temperature Range
Corresponding to flange specification - 0...60 bar
5 items

CAS Pressure Switch & Thermostat
2359
In the Danfoss CAS pressure switches and thermostat series, special attention has been given to meeting demands for a high level of enclosure, low differential, robust, compact construction and resistance to shock and vibration. The Danfoss CAS series covers most outdoor as well as indoor application requirements. CAS pressure switches are suitable for use in alarm and regulation systems in factories, diesel plant, compressors, power stations and onboard ships.
- USD

KPS Pressure Switch
2362
In the Danfoss KPS switches series, special attention has been given to meeting important demands for a high level of enclosure, robustness, compact construction and resistance to shock and vibration. The Danfoss KPS pressure switch covers most outdoor as well as indoor application requirements, and are suitable for use in alarm and regulation systems in factories, diesel plant, compressors, power station and onboard ships.
- USD

MBS 4010 Pressure Transmitter
5139
The Danfoss MBS 4010 pressure transmitter with the optional flush diaphragm is designed for use in almost all industrial applications with non-uniform, high viscous or crystallising mediums, and offers a reliable pressure measurement, even under harsh environmental conditions. A robust design, excellent vibration stability and a high degree of EMC / EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
- USD

KPS Pressure Switch & Thermostat
5306
The Danfoss KPS thermostat and pressure switch series consists of a series of pressure and temperature controlled switches. In the Danfoss KPS series, special attention has been given to meeting demands for a high level of enclosure, robust and compact construction, and resistance to shock and vibration. For the Danfoss KPS pressure switches, the position of the contacts depends on the pressure in the inlet connection and the set scale value. For KPS thermostats, the position of the contacts depends on the temperature of the sensor and the fixed scale value. The series covers most outdoor and indoor application requirements and is suitable for use in monitoring alarm and control systems in factories, diesel plants, compressors, power stations, and board ships. Available types: Danfoss KPS 76 Pressure Switch and Thermostat Danfoss KPS 77 Pressure Switch and Thermostat Danfoss KPS 79 Pressure Switch and Thermostat Danfoss KPS 80 Pressure Switch and Thermostat Danfoss KPS 81 Pressure Switch and Thermostat Danfoss KPS 83 Pressure Switch and Thermostat
- USD

VTR1010...1300 Turbine Flow Sensor
7800
The SIKA VTR1010…1300 turbine flow sensor allows you to determine precisely, dependably and easily the flow rates of different liquids, such as water and other low viscosity liquids, under the most severe conditions. The SIKA VTR1010…1300 sensor is particularly robust and, due to the wide range of nominal diameters and five different pick-ups, can cope with even the most severe conditions. The characteristic variable is the K-factor (pulses per litre) which is specific to each measuring unit, is determined by calibration and specified on the nameplate. A five-point calibration report can be supplied on request. The VTR sensor consists of the measuring turbine and a pick-up mounted on the outside. The liquid flows into the measuring turbine and causes the rotor to move. Due to the characteristic internal diameter, the speed of rotation is directly proportional to the flow rate. The moving rotor blades are detected by the pick-up and this is converted into a pulsed signal proportional to the flow rate.
- USD
1 - 5 of 5
1