Filter Sort
close
1 - 5 of 5
990.40 Threaded Connection Diaphragm Seal

990.40 Threaded Connection Diaphragm Seal

2249

The WIKA 990.40 diaphragm seal with threaded connection in threaded design is suitable for versatile application areas. A replacement of the lower body is possible without modifications on the diaphragm seal system. With this diaphragm seal, low-pressure ranges can be covered ” the large diameter of the diaphragm affects a lower deviation at the measuring instrument when the temperature changes. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the upper body of the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be coated.
View Details
990.17 Sterile Connection Diaphragm Seal

990.17 Sterile Connection Diaphragm Seal

2297

Thanks to its flush process connection, the WIKA 990.17 diaphragm seal is optimally suited for installation in storage tanks. With a suitable welding flange, this diaphragm seal can be integrated into any type of tank or vessel. Level measurement with diaphragm seals also works with media that, due to the process, are under pressure and have high or low viscosity. The WIKA 990.17 diaphragm seal is particularly suitable for CIP cleaning processes as it meets the requirements for elevated temperatures and chemical resistance to cleaning solutions. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be electropolished.
View Details
MBS 9300 Pressure Transmitter

MBS 9300 Pressure Transmitter

2374

Compact Danfoss MBS 9300 pressure transmitter (gauge version) is designed for use in marine applications, e.g. crankcase and turbocharger filters monitoring and applications within level measurement. The MBS 9300 pressure transmitter covers a 4 “ 20 mA and ratiometric 10-90% of supply output signals, a pressure span from 40 “ 400 mbar, and bidirectional ranges. Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
View Details
CS Pressure Switch

CS Pressure Switch

5294

The Danfoss CS pressure switch series has a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the range setting and adjustable differential. The Danfoss CS pressure switches are fitted with a manual switch that will lock the contact system in the open position independently of the pressure in the system. Pressure switches with relief valve are used in compressed air systems where pressure relief on the compressor piston before the start is required. The CS is suited for an automatic start and stop of air compressors and water boosters.
View Details
CPC2000 Portable Low-Pressure Controller

CPC2000 Portable Low-Pressure Controller

8212

The WIKA CPC2000 portable low pressure controller is used in the areas of heating, ventilation, air conditioning, filtration, clean room, and medical technology as a calibrator or as highly-accurate measurement equipment and/or precise pressure transducer. The WIKA CPC2000 low-pressure controller is a mains or battery-operated pressure controller with internal, automatic pressure generation and pressure reference. The pressure generation is achieved using an integrated, electric pump, which makes a positive and/or negative pressure available on both the tube connections. As soon as the instrument is switched on, a zero-point adjustment is automatically carried out, so that a zero-point drift is eliminated. The subsequent preparation of a calibration requires only a few settings. First, using the MENU button, select one of the stored pressure units and the variable pressure change step in the range of 0 … 50 %. Then, once the full scale has been entered in Control Mode, the pressure can be easily increased or decreased by the defined level using the navigation buttons. To check whether the calibration assembly or the test item has a leak, the LEAK button can be used. With this, the pressure is locked into the test assembly and any pressure drop there might be, as well as the the time this takes, is measured and displayed. The CPC2000 has an RS-232 and USB interface, enabling communication and data exchange with a PC. WIKA-Cal calibration software is available for the CPC2000. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. The accuracy of the instrument is certified by a factory calibration certificate.
View Details
1 - 5 of 5
1