close
Categories
Filter By
Company
Connection Type
Medium Temperature
Pressure Range
- 0...0.6 bar 1
- 0...0.6 bar__0...40 bar 5
- 0...0.6 bar__0...40 bar__PN 16/40 or Class 150/300 1
- 0...1.000 bar 1
- 0...1.000 mbar 1
- 0...1 bar__0...10 bar 1
- 0...1 bar__0...25 bar 1
- 0...1 bar__0...40 bar 1
- 0...10.000 bar 1
- 0...10 bar__0...600 bar 1
- 0...16 bar 1
- 0...25 bar 3
- 0...40 bar 1
- 0...60 bar 4
- 0...100 bar 1
- 0...250 bar 1
- 0...400 bar 2
- 0...600 bar 9
- 0...700 bar 3
- 0...1000 bar 2
- 0...1600 bar 1
- 2...20 bar 1
- 10 bar 1
- 10 bar__6 bar__8 bar 6
- 20 bar 1
- 25 bar__40 bar 2
- 25 mbar 1
- 40...400 mbar 1
- 100 bar 1
- 250 bar 1
- 300 bar 1
- 350...400 bar 2
- -0.2...21 bar 1
- -0.2...400 bar 1
- -0.95...40 bar 1
- -0.95...60 bar 1
- -1...1 bar__0...2.000 bar 1
- -1...1 bar__0...2500 bar 1
- -1...2 bar__0...1000 bar 1
- -1...3 bar__0...700 bar 1
- -1...3 bar__0...1000 bar 1
- -1...10 bar__0...1000 bar 1
- -1...18 bar 1
- -1...60 bar 1
- -1...210 bar 2
- -1...250 bar 1
- -1...400 bar 1
- -1...1000 bar 1
- Corresponding to flange specification 1
- From 400 mbar depending on diameter of diaphragm 1
- PN 10 10
- PN 10 €“ 100; Class 150 - 600 1
- PN 16 8
- PN 25 5
- PN 50 2
0...100 bar, 20 bar, 40...400 mbar - 350...400 bar
5 items

990.40 Threaded Connection Diaphragm Seal
2249
The WIKA 990.40 diaphragm seal with threaded connection in threaded design is suitable for versatile application areas. A replacement of the lower body is possible without modifications on the diaphragm seal system. With this diaphragm seal, low-pressure ranges can be covered ” the large diameter of the diaphragm affects a lower deviation at the measuring instrument when the temperature changes. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the upper body of the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be coated.
- USD

MBS 9300 Pressure Transmitter
2374
Compact Danfoss MBS 9300 pressure transmitter (gauge version) is designed for use in marine applications, e.g. crankcase and turbocharger filters monitoring and applications within level measurement. The MBS 9300 pressure transmitter covers a 4 “ 20 mA and ratiometric 10-90% of supply output signals, a pressure span from 40 “ 400 mbar, and bidirectional ranges. Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
- USD

VH780 Flow Switch
7590
The SIKA VH780 flow switch monitors the flow of low-viscosity media in pipes. The SIKA VH780 offers a reliable solution for ensuring the minimum flow rate and thereby protecting high-quality systems and installations from damages. These flow switches work based on the well- established mechanical operating principles. Thanks to the different paddle lengths, the switch points of the paddle flow switches can be configured for a wide switching range. The flowing medium hits the plate secured to the end of a paddle. The resulting dynamic pressure causes the paddle to travel. This, in turn, causes the actuation of a micro switch. The flowing medium hits the plate secured to the end of a paddle. The resulting dynamic pressure causes the paddle to travel. This, in turn, causes the actuation of a micro switch.
- USD

VZVA Positive Displacement Flow Sensor
7830
SIKA's gearwheel type VZVA positive displacement flow sensor records volume flows of liquids with both high and changing viscosities. The high-precision sensors work according to the displacement principle. The high resolution combined with reliable measurement accuracy makes the sensors especially useful for applications involving the measurement of small and minimal volumes. A very precisely adjusted gear pair within the casing forms the measuring element. The inflowing medium causes the gear pair to rotate. Contactless sensors scan the rotary motion. Since each tooth generates a pulse, this results in a very high resolution. Consequently, even the smallest volumes can be measured or dosed precisely. The measurement unit contains two pick-offs that are circumferentially offset by ¼ of a tooth pitch to generate a two-channel flow-proportional frequency signal. Suitable processing of the signal provides a higher resolution and the option to identify the flow direction. The maximum pressure drop should not exceed 16 bar. This limits the measurement range of high viscosity media (see pressure drop diagrams). The measurement accuracy increases with an increase in viscosity of the media.
- USD

VZGG Positive Displacement Flow Sensor
7835
SIKA™s gearwheel type VZGG positive displacement flow sensor records volume flows of liquids with both high and changing viscosities. The high-precision sensors work according to the displacement principle. The high resolution combined with reliable measurement accuracy makes the sensors especially useful for applications involving the measurement of small and minimal volumes. A very precisely adjusted gear pair within the casing forms the measuring element. The inflowing medium causes the gear pair to rotate. Contactless sensors scan the rotary motion. Since each tooth generates a pulse, this results in a very high resolution. Consequently, even the smallest volumes can be measured or dosed precisely. The measurement unit contains two pick-offs that are circumferentially offset by ¼ of a tooth pitch to generate a two-channel flow-proportional frequency signal. Suitable processing of the signal provides a higher resolution and the option to identify the flow direction. The maximum pressure drop should not exceed 16 bar. This limits the measurement range of high viscosity media (see pressure drop diagrams). The measurement accuracy increases with an increase in viscosity of the media.
- USD
1 - 5 of 5
1