Filter Sort
close
1 - 9 of 10
990.40 Threaded Connection Diaphragm Seal

990.40 Threaded Connection Diaphragm Seal

2249

The WIKA 990.40 diaphragm seal with threaded connection in threaded design is suitable for versatile application areas. A replacement of the lower body is possible without modifications on the diaphragm seal system. With this diaphragm seal, low-pressure ranges can be covered ” the large diameter of the diaphragm affects a lower deviation at the measuring instrument when the temperature changes. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the upper body of the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be coated.
View Details
D2 Digital Pressure Gauge

D2 Digital Pressure Gauge

4883

The SIKA D2 digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA D2 digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. High accuracy in a signal acquisition is achieved by using high-performance measuring cells with electronic linearisation of the characteristic curve. Suitable instruments are available for a wide variety of measurement tasks. Ease of use is assured by innovative design and advanced technology. All essential functions for everyday use can be selected conveniently at the press of a button. Excellent protection against dust and moisture is provided by a membrane keypad or rubber buttons. Integrated supplementary functions make our digital pressure gauges true all-rounders. Display The large illuminated digital local display shows the measured pressure and indicates the current status of the digital pressure gauge, even under poor lighting conditions. This eliminates the difficult task of reading a dial gauge and avoiding parallax errors. Needle jitter due to vibration or pressure fluctuations is eliminated. Display damping or averaging can be configured directly using display filters. This ensures easy, tireless readout. Protection class High IP protection classes (IP67 (front) / IP67) are available to minimise dust and water sensitivity. Rugged, impact-resistant digital pressure gauges are fitted with rubber caps for protection during transport and field use. Battery operation / Auto-Off Power is supplied by long-life batteries (ordinary or rechargeable). An external AC adapter can also be used. To increase battery operating time, a Programmable Auto-Off function switches off the power to the instrument after prolonged inactivity. The electronics are designed for extremely low power consumption, which enables battery life of significantly more than 1500 hours.
View Details
Digital Pressure Gauge Type P

Digital Pressure Gauge Type P

4886

The SIKA Type P digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA Type P digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. Linearisation Multi-point adjustment can be performed if it is necessary to adjust the indicated values at different test points. Two-point adjustment is available for setting the zero point and slope of the measuring cell curve. Type P digital pressure gauges allow up to six offset values to be programmed to shift the characteristic curve to meet the most stringent customer expectations. PC connection and software Many digital pressure gauges have a serial interface port to allow measurement values and stored data to be transferred directly to a PC and documented. An inexpensive measurement data acquisition system can easily be assembled with suitable software and an interface converter. Processes can be readily monitored and analysed using the recorded and visualised measurements, and all data can be exported using standard programs such as Microsoft Excel. Remote control is also possible. Various software packages with extensive recording and display functions, logger and alarm evaluation as well as for calibration are available. Analogue output An electrical output signal enables remote display on a control console or in a control room as well as the connection of external recorders and indicating instruments. Relay output Digital pressure gauges allow limit contacts to be closed even at low pressures. There is no need for high actuation forces for magnetic spring or inductive contacts, which makes it easier to signal critical equipment conditions and perform supplementary control tasks.
View Details
L-Ex Digital Pressure Gauge

L-Ex Digital Pressure Gauge

4895

The SIKA L-Ex digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA L-Ex digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. High accuracy in the signal acquisition is achieved by using high-performance measuring cells with electronic linearisation of the characteristic curve. Suitable instruments are available for a wide variety of measurement tasks. Ease of use is assured by innovative design and advanced technology. All essential functions for everyday use can be selected conveniently at the press of a button. Excellent protection against dust and moisture is provided by a membrane keypad or rubber buttons. Integrated supplementary functions make our digital pressure gauges true all-rounders. PC connection and software Many digital pressure gauges have a serial interface port to allow measurement values and stored data to be transferred directly to a PC and documented. An inexpensive measurement data acquisition system can easily be assembled with suitable software and an interface converter. Processes can be readily monitored and analysed using the recorded and visualised measurements, and all data can be exported using standard programs such as Microsoft Excel. A remote control is also possible. Various software packages with extensive recording and display functions, logger and alarm evaluation as well as for calibration are available. Analogue output An electrical output signal enables remote display on a control console or in a control room as well as the connection of external recorders and indicating instruments. Relay output Digital pressure gauges allow limit contacts to be closed even at low pressures. There is no need for high actuation forces for magnetic spring or inductive contacts, which makes it easier to signal critical equipment conditions and perform supplementary control tasks.
View Details
VMZ 25 Magnetic Inductive Flow Sensor

VMZ 25 Magnetic Inductive Flow Sensor

7633

The SIKA VMZ 25 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 25 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 25 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
VMZ 20 Magnetic Inductive Flow Sensor

VMZ 20 Magnetic Inductive Flow Sensor

7637

The SIKA VMZ 20 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 20 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 20 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
VMZ 15 Magnetic Inductive Flow Sensor

VMZ 15 Magnetic Inductive Flow Sensor

7639

The SIKA VMZ 15 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 15 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 15 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
VMZ 08 Magnetic Inductive Flow Sensor

VMZ 08 Magnetic Inductive Flow Sensor

7641

The SIKA VMZ 08 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 08 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 08 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
VMZ 06 Magnetic Inductive Flow Sensor

VMZ 06 Magnetic Inductive Flow Sensor

7643

The SIKA VMZ 06 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 06 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 06 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
1 - 9 of 10