Filter Sort
close
1 - 3 of 3
990.17 Sterile Connection Diaphragm Seal

990.17 Sterile Connection Diaphragm Seal

2297

Thanks to its flush process connection, the WIKA 990.17 diaphragm seal is optimally suited for installation in storage tanks. With a suitable welding flange, this diaphragm seal can be integrated into any type of tank or vessel. Level measurement with diaphragm seals also works with media that, due to the process, are under pressure and have high or low viscosity. The WIKA 990.17 diaphragm seal is particularly suitable for CIP cleaning processes as it meets the requirements for elevated temperatures and chemical resistance to cleaning solutions. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be electropolished.
View Details
KP Pressure Switch

KP Pressure Switch

5288

The Danfoss KP pressure switches are used for regulating, monitoring and alarm systems in the industry. The KP pressure switches provide automatic limit protection or manual reset limit protection for pressure systems. The KP switches can be used with steam, air, gaseous and liquid media. The pressure switches are fitted with a single-pole changeover switch (SPDT). The position of the switch depends on the setting of the pressure switch and the pressure in the connector. Available types: KP 34 pressure switch KP 35 pressure switch KP 36 pressure switch KP 37 pressure switch KP 44 pressure switch
View Details
VH780 Flow Switch

VH780 Flow Switch

7590

The SIKA VH780 flow switch monitors the flow of low-viscosity media in pipes. The SIKA VH780 offers a reliable solution for ensuring the minimum flow rate and thereby protecting high-quality systems and installations from damages. These flow switches work based on the well- established mechanical operating principles. Thanks to the different paddle lengths, the switch points of the paddle flow switches can be configured for a wide switching range. The flowing medium hits the plate secured to the end of a paddle. The resulting dynamic pressure causes the paddle to travel. This, in turn, causes the actuation of a micro switch. The flowing medium hits the plate secured to the end of a paddle. The resulting dynamic pressure causes the paddle to travel. This, in turn, causes the actuation of a micro switch.
View Details
1 - 3 of 3