990.10 Threaded Connection Diaphragm Seal

990.10 Threaded Connection Diaphragm Seal

1522

The WIKA 990.10 diaphragm seal with threaded connection in threaded design is suitable for versatile application areas. A replacement of the lower body is possible without modifications on the diaphragm seal system. With this diaphragm seal, high pressure ranges up to 250 bar can be covered. Compared to the WIKA 990.40 diaphragm seal, higher pressure ranges can be covered (smaller diameter of the diaphragm). Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the upper body of the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be coated.    
View Details
MBS 9300 Pressure Transmitter

MBS 9300 Pressure Transmitter

2374

Compact Danfoss MBS 9300 pressure transmitter (gauge version) is designed for use in marine applications, e.g. crankcase and turbocharger filters monitoring and applications within level measurement. The MBS 9300 pressure transmitter covers a 4 “ 20 mA and ratiometric 10-90% of supply output signals, a pressure span from 40 “ 400 mbar, and bidirectional ranges. Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
View Details
VTY 20 Turbine Flow Sensor

VTY 20 Turbine Flow Sensor

2808

The SIKA VTY 20 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. Turbine flow sensors of the series VTY stainless steel were specially developed for the use in industrial applications. The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials – sapphire and hard metal – also guarantee an exceptionally long endurance.
View Details
990.31 Threaded Connection Diaphragm Seal

990.31 Threaded Connection Diaphragm Seal

3243

The WIKA 990.31 diaphragm seal with threaded connection in a plastic version is suitable for versatile application areas in the water supply and wastewater treatment industries. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection or a flexible capillary. The WIKA 990.31 diaphragm seal is used successfully in chemical plant construction, electroplating and wastewater treatment applications.
View Details
100.0x / 100.1x Bimetall-Thermomanometer

100.0x / 100.1x Bimetall-Thermomanometer

3298

The WIKA 100.1, 100.2, 100.10 and 100.12 thermomanometer with a bimetal system is fitted directly at the measuring point via a stem. The valve allows the measuring instrument to be unscrewed without having to empty the heating system first. Due to the combination of a pressure gauge and a bimetal thermometer the instrument can be used flexibly in a wide variety of applications. The WIKA thermomanometer with bimetal system is fitted directly at the measuring point via a stem. The valve allows the measuring instrument to be unscrewed without having to empty the heating system first. Due to the combination of a pressure gauge and a bimetal thermometer the instrument can be used flexibly in a wide variety of applications
View Details
MBS 1900 Pressure Transmitter

MBS 1900 Pressure Transmitter

5119

The Danfoss MBS 1900 pressure transmitter is designed for use in air and water applications like Booster Pumps and Air Compressors. The semi-flexible pressure transmitter programme covers different output signals, absolute or gauge (relative) versions, measuring ranges from 0…4 bar to 0…25 bar and a wide range of pressure and electrical connections. The enclosure material is stainless steel AISI 316L.
View Details
MBS 3100/3150 Pressure Transmitter

MBS 3100/3150 Pressure Transmitter

5134

The compact ship approved Danfoss MBS 3100, and MBS 3150 pressure transmitters are designed for almost all marine applications. The Danfoss MBS 3150 pressure transmitter with integrated pulse-snubber is suitable in marine applications with severe medium influences like cavitation, liquid hammer or pressure peaks. It offers a reliable pressure measurement, even under harsh environmental conditions. Excellent vibration stability, robust construction, and a high degree of EMC / EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
View Details
MBS 4510 Pressure Transmitter

MBS 4510 Pressure Transmitter

5151

The high accuracy Danfoss MBS 4510 pressure transmitter with flush diaphragm is designed for use in non-uniform, high viscous or crystallising media within industrial applications. It offers a reliable pressure measurement, even under harsh environmental conditions. The flexible MBS 4510 pressure transmitter covers a 4-20 mA output signal, absolute and gauge (relative) versions, measuring ranges from 0-0.25 to 0-25 bar zero and span adjustment. A rotatable plug connection and a G1A conic pressure connection with a flush mounted diaphragm. Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
View Details
VMI 20 Magnetic Inductive Flow Sensor

VMI 20 Magnetic Inductive Flow Sensor

7647

Due to the robust metal housing and stable metal process connections, the SIKA VMI 20 is ideal for use in the field of mechanical engineering and plant construction. Its design also makes it suitable for higher temperatures and process pressures, and the instrument is available in three different sizes. All sensors will be delivered with a works calibration certificate. The smart flow sensors of the SIKA VMI 20 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.