Filter Sort
close
1 - 6 of 6
CPH6200 Pressure Indicator

CPH6200 Pressure Indicator

3109

For the WIKA CPH6200 pressure controller, WIKA CPT6200 pressure sensors are available for reference pressure with measuring ranges of up to 1000 bar. Therefore, it is particularly suitable as a test instrument for applications such as process technology, machine building, etc. The digital indicator automatically detects the measuring range of the connected pressure sensor and guarantees a highly accurate pressure measurement. The WIKA CPH6200 Pressure indicator can be used for measuring both gauge and absolute pressure. Differential pressure measurement is possible with the 2-channel version CPH6200-S2, and two connected model CPT6200 reference pressure sensors. Pressure units selectable on the instrument are bar, mbar, psi, Pa, kPa, MPa, mmHg or inHg. An integrated data logger and various other functions such as Min., Max., Hold, Tare, zero point adjustment, alarm, power-off, peak value detection (1,000 measurements/s), average value filter, etc. ensure that the CPH6200 can be used for many different applications. In addition to the GSoft data-logger evaluation software for the tabular and graphical representation of the logged data, WIKA-Cal calibration software for calibration tasks is also available. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. A USB interface is available for data transfer.
View Details
CPH6300 Pressure Indicator

CPH6300 Pressure Indicator

3112

Stainless steel pressure sensors with measuring ranges up to 1,000 bar are available for the WIKA CPH6300 Pressure Indicator. The robust and waterproof design makes the CPH6300 ideal for use in adverse environments. The digital indicator automatically detects the measuring range of the connected pressure sensor and guarantees a highly accurate pressure measurement. The WIKA CPH6300 Pressure Indicator can be used for measuring both gauge and absolute pressure. Differential pressure measurement is possible with the 2-channel version CPH6300-S2, and two connected model CPT6200 reference pressure sensors. Selectable pressure units here are bar, mbar, psi, Pa, kPa, MPa, mmHg, inHg, mH2O and one customer-specific unit. An integrated data logger and various other functions such as Min., Max., Hold, Tare, zero point adjustment, alarm, power-off, peak value detection (1,000 measurements/s), average value filter, etc. ensure that the CPH6300 can be used for many different applications. The large, backlit display and also a long battery life complete the features of the CPH6300 Pressure Indicator. In addition to the GSoft data logger evaluation software for the tabular and graphical representation of the logged data, WIKA-Cal calibration software for calibration tasks is also available. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. A USB interface is available for the data transfer.
View Details
990.31 Threaded Connection Diaphragm Seal

990.31 Threaded Connection Diaphragm Seal

3243

The WIKA 990.31 diaphragm seal with threaded connection in a plastic version is suitable for versatile application areas in the water supply and wastewater treatment industries. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection or a flexible capillary. The WIKA 990.31 diaphragm seal is used successfully in chemical plant construction, electroplating and wastewater treatment applications.
View Details
EXPD 920/924/932 Differential Pressostat

EXPD 920/924/932 Differential Pressostat

3989

The Trafag EXPD 920/924/932 ex differential pressostat electromechanical pressure switches provide high vibration resistance and switch point precision in combination with an extremely robust and durable design. This results in switches that can be operated for decades without requiring maintenance, even under harsh conditions. Various designs with bellows, membrane and piston sensors cover a wide variety of pressure ranges, media and load profiles for many different applications.
View Details
Digital Pressure Gauge Type J

Digital Pressure Gauge Type J

4892

The SIKA Type J digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA Type J digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. PC connection and software Many digital pressure gauges have a serial interface port to allow measurement values and stored data to be transferred directly to a PC and documented. An inexpensive measurement data acquisition system can easily be assembled with suitable software and an interface converter. Processes can be readily monitored and analysed using the recorded and visualised measurements, and all data can be exported using standard programs such as Microsoft Excel. Remote control is also possible. Various software packages with extensive recording and display functions, logger and alarm evaluation as well as for calibration are available. Analogue output An electrical output signal enables remote display on a control console or in a control room as well as the connection of external recorders and indicating instruments. Relay output Digital pressure gauges allow limit contacts to be closed even at low pressures. There is no need for high actuation forces for magnetic spring or inductive contacts, which makes it easier to signal critical equipment conditions and perform supplementary control tasks.
View Details
VTR1010...1050 Turbine Flow Sensor

VTR1010...1050 Turbine Flow Sensor

7799

The SIKA VTR1010…1050 turbine flow sensor allows you to determine precisely, dependably and easily the flow rates of different liquids, such as water and other low viscosity liquids, under the most severe conditions. The SIKA VTR1010…1050 sensor is particularly robust and, due to the wide range of nominal diameters and five different pick-ups, can cope with even the most severe conditions. The characteristic variable is the K-factor (pulses per litre) which is specific to each measuring unit, is determined by calibration and specified on the nameplate. A five-point calibration report can be supplied on request. The VTR sensor consists of the measuring turbine and a pick-up mounted on the outside. The liquid flows into the measuring turbine and causes the rotor to move. Due to the characteristic internal diameter, the speed of rotation is directly proportional to the flow rate. The moving rotor blades are detected by the pick-up and this is converted into a pulsed signal proportional to the flow rate.
View Details
1 - 6 of 6