Filter Sort
close
1 - 7 of 7
990.23 Diaphragm Seal

990.23 Diaphragm Seal

2279

The WIKA 990.23 diaphragm seal has been developed for use in pulp manufacture or waste-paper processing applications. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. Optionally, there are pipe elbows and vibration dampers available. For the material selection, WIKA offers a variety of solutions, in which the upper body of the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be coated. Applications Chemical pulp manufacture Recovered/recycled paper treatment For highly viscous, aggressive or hardening media
View Details
981.22 In-Line Diaphragm Seal

981.22 In-Line Diaphragm Seal

2300

The WIKA 981.22, 981.52 and 981.53 in-line diaphragm seals are suitable for use in the measurement of flowing media. In addition to avoiding potential blockages in the process, in-line measurement technology also contributes to securing product quality, mainly through its perfect cleanability. Due to the continuous cylindrical diaphragm, the measuring locations feature neither dead spaces nor non-flushable branches. The good cleanability of the in-line diaphragm seals has been tested and confirmed by independent institutions (e.g. EHEDG, BioProcessing Institute). The diaphragm seals can withstand the cleaning vapour temperatures occurring in the SIP processes and thus ensure a sterile connection between the medium to be measured and the diaphragm seal. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. The availability of in-line diaphragm seals for common pipe standards and nominal widths simplifies integration into already existing pipe cross-sections.
View Details
990.1x & 990.2x Sterile Connection Diaphragm Seal

990.1x & 990.2x Sterile Connection Diaphragm Seal

2306

The WIKA 990.18, 990.19, 990.20 and 990.21 sterile connection diaphragm seals with threaded connection are particularly suited for use in the food industry. The diaphragm seals can withstand the cleaning vapour temperatures occurring in the SIP processes and thus ensure a sterile connection between the medium to be measured and the diaphragm seal. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the upper body of the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an option, be electropolished. Applications Food and beverage production For dairies, dairy products Breweries Soft drink production
View Details
981.5x In-Line Diaphragm Seal

981.5x In-Line Diaphragm Seal

3106

The WIKA 981.52 and 981.53 In-Line diaphragm seals with clamp connections, due to their circular design, can be mounted directly into the pipeline, meaning no special measuring point connection is required. Through the integration into the process line, turbulences, dead spaces, corners and other obstructions can be avoided. For this diaphragm seal, WIKA uses a completely round diaphragm, which, due to the unobstructed flow of the media, produces an automatic cleaning of the chamber. The diaphragm seal systems can withstand the cleaning vapour temperatures occurring in the SIP processes and thus ensure a sterile connection between the medium to be measured and the diaphragm seal. Assembly of the diaphragm seal and measuring instrument is made via a direct assembly as standard or optionally via a cooling element or a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the upper body and the diaphragm are made of identical materials. Stainless steel 316L (1.4435) is used as standard material, other special materials are available on request. Measuring systems with model 981.22 , 981.52 and 981.53 WIKA diaphragm seals are successfully used in the life science industry, in food production, pharmaceutical and biotechnology applications.
View Details
"990.22, 990.52, 990.53 Sterile Connection Diaphragm Seal"

"990.22, 990.52, 990.53 Sterile Connection Diaphragm Seal"

7085

Due to their hygienic process connection, the WIKA 990.22, 990.52 and 990.53 diaphragm seals with sterile connection are particularly well suited for food production, pharmaceutical and biotechnology applications. The diaphragm seals can withstand the cleaning vapour temperatures occurring in the SIP processes and thus ensure a sterile connection between the medium to be measured and the diaphragm seal. Mounting of the diaphragm seal to the measuring instrument may be made via a direct connection, for high temperatures via a cooling element or via a flexible capillary. For the material selection, WIKA offers a variety of solutions, in which the upper body of the diaphragm seal and the wetted parts can be made of identical or different materials. The wetted parts can, as an alternative, be electropolished.
View Details
VTR1010...1300 Turbine Flow Sensor

VTR1010...1300 Turbine Flow Sensor

7800

The SIKA VTR1010…1300 turbine flow sensor allows you to determine precisely, dependably and easily the flow rates of different liquids, such as water and other low viscosity liquids, under the most severe conditions. The SIKA VTR1010…1300 sensor is particularly robust and, due to the wide range of nominal diameters and five different pick-ups, can cope with even the most severe conditions. The characteristic variable is the K-factor (pulses per litre) which is specific to each measuring unit, is determined by calibration and specified on the nameplate. A five-point calibration report can be supplied on request. The VTR sensor consists of the measuring turbine and a pick-up mounted on the outside. The liquid flows into the measuring turbine and causes the rotor to move. Due to the characteristic internal diameter, the speed of rotation is directly proportional to the flow rate. The moving rotor blades are detected by the pick-up and this is converted into a pulsed signal proportional to the flow rate.
View Details
CPC2000 Portable Low-Pressure Controller

CPC2000 Portable Low-Pressure Controller

8212

The WIKA CPC2000 portable low pressure controller is used in the areas of heating, ventilation, air conditioning, filtration, clean room, and medical technology as a calibrator or as highly-accurate measurement equipment and/or precise pressure transducer. The WIKA CPC2000 low-pressure controller is a mains or battery-operated pressure controller with internal, automatic pressure generation and pressure reference. The pressure generation is achieved using an integrated, electric pump, which makes a positive and/or negative pressure available on both the tube connections. As soon as the instrument is switched on, a zero-point adjustment is automatically carried out, so that a zero-point drift is eliminated. The subsequent preparation of a calibration requires only a few settings. First, using the MENU button, select one of the stored pressure units and the variable pressure change step in the range of 0 … 50 %. Then, once the full scale has been entered in Control Mode, the pressure can be easily increased or decreased by the defined level using the navigation buttons. To check whether the calibration assembly or the test item has a leak, the LEAK button can be used. With this, the pressure is locked into the test assembly and any pressure drop there might be, as well as the the time this takes, is measured and displayed. The CPC2000 has an RS-232 and USB interface, enabling communication and data exchange with a PC. WIKA-Cal calibration software is available for the CPC2000. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. The accuracy of the instrument is certified by a factory calibration certificate.
View Details
1 - 7 of 7
1