close
Categories
Filter By
Company
Medium Temperature
Pressure Range
- 0...0.6 bar 1
- 0...0.6 bar__0...40 bar 5
- 0...0.6 bar__0...40 bar__PN 16/40 or Class 150/300 1
- 0...1.000 bar 1
- 0...1.000 mbar 1
- 0...1 bar__0...10 bar 1
- 0...1 bar__0...25 bar 1
- 0...1 bar__0...40 bar 1
- 0...10.000 bar 1
- 0...10 bar__0...600 bar 1
- 0...16 bar 1
- 0...25 bar 3
- 0...40 bar 1
- 0...60 bar 4
- 0...100 bar 1
- 0...250 bar 1
- 0...400 bar 2
- 0...600 bar 9
- 0...700 bar 3
- 0...1000 bar 2
- 0...1600 bar 1
- 2...20 bar 1
- 10 bar 1
- 10 bar__6 bar__8 bar 6
- 20 bar 1
- 25 bar__40 bar 2
- 25 mbar 1
- 40...400 mbar 1
- 100 bar 1
- 250 bar 1
- 300 bar 1
- 350...400 bar 2
- -0.2...21 bar 1
- -0.2...400 bar 1
- -0.95...40 bar 1
- -0.95...60 bar 1
- -1...1 bar__0...2.000 bar 1
- -1...1 bar__0...2500 bar 1
- -1...2 bar__0...1000 bar 1
- -1...3 bar__0...700 bar 1
- -1...3 bar__0...1000 bar 1
- -1...10 bar__0...1000 bar 1
- -1...18 bar 1
- -1...60 bar 1
- -1...210 bar 2
- -1...250 bar 1
- -1...400 bar 1
- -1...1000 bar 1
- Corresponding to flange specification 1
- From 400 mbar depending on diameter of diaphragm 1
- PN 10 10
- PN 10 €“ 100; Class 150 - 600 1
- PN 16 8
- PN 25 5
- PN 50 2
0...0.6 bar, 10 bar__6 bar__8 bar - -1...2 bar__0...1000 bar
8 items

990.15 Flanged Process Connection Diaphragm Seal
2282
Together with a block flange or a saddle flange, the WIKA 990.15 diaphragm seal forms a perfectly matched system. Through the process connection via block flanges or saddle flanges, compact assemblies can be optimally realised at the measuring point. Depending on customer requirements, the model 990.15 can be subsequently integrated into a process using the accessory models 910.19, 910.20 and 910.23. The process connection is designed as a flange connection. The measuring instrument is in a vertical position. Applications Specifically for connection with block flange or saddle flange and to combine with bourdon tube pressure gauges Suitable for corrosive, contaminated, hot or viscous pressure media Chemical and petrochemical industry
- USD

L-Ex Digital Pressure Gauge
4895
The SIKA L-Ex digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA L-Ex digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. High accuracy in the signal acquisition is achieved by using high-performance measuring cells with electronic linearisation of the characteristic curve. Suitable instruments are available for a wide variety of measurement tasks. Ease of use is assured by innovative design and advanced technology. All essential functions for everyday use can be selected conveniently at the press of a button. Excellent protection against dust and moisture is provided by a membrane keypad or rubber buttons. Integrated supplementary functions make our digital pressure gauges true all-rounders. PC connection and software Many digital pressure gauges have a serial interface port to allow measurement values and stored data to be transferred directly to a PC and documented. An inexpensive measurement data acquisition system can easily be assembled with suitable software and an interface converter. Processes can be readily monitored and analysed using the recorded and visualised measurements, and all data can be exported using standard programs such as Microsoft Excel. A remote control is also possible. Various software packages with extensive recording and display functions, logger and alarm evaluation as well as for calibration are available. Analogue output An electrical output signal enables remote display on a control console or in a control room as well as the connection of external recorders and indicating instruments. Relay output Digital pressure gauges allow limit contacts to be closed even at low pressures. There is no need for high actuation forces for magnetic spring or inductive contacts, which makes it easier to signal critical equipment conditions and perform supplementary control tasks.
- USD

VMZ 25 Magnetic Inductive Flow Sensor
7633
The SIKA VMZ 25 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 25 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 25 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 20 Magnetic Inductive Flow Sensor
7637
The SIKA VMZ 20 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 20 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 20 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 15 Magnetic Inductive Flow Sensor
7639
The SIKA VMZ 15 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 15 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 15 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 08 Magnetic Inductive Flow Sensor
7641
The SIKA VMZ 08 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 08 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 08 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 06 Magnetic Inductive Flow Sensor
7643
The SIKA VMZ 06 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 06 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 06 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 03 Magnetic Inductive Flow Sensor
7645
The SIKA VMZ 03 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 03 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 03 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD
1 - 8 of 8
1