close
Categories
Filter By
Company
Accuracy
Ambient Temperature
Connection Type
Measuring range
Pressure Range
- 0...0.6 bar 1
- 0...0.6 bar__0...40 bar 5
- 0...0.6 bar__0...40 bar__PN 16/40 or Class 150/300 1
- 0...1.000 bar 1
- 0...1.000 mbar 1
- 0...1 bar__0...10 bar 1
- 0...1 bar__0...25 bar 1
- 0...1 bar__0...40 bar 1
- 0...10.000 bar 1
- 0...10 bar__0...600 bar 1
- 0...16 bar 1
- 0...25 bar 3
- 0...40 bar 1
- 0...60 bar 4
- 0...100 bar 1
- 0...250 bar 1
- 0...400 bar 2
- 0...600 bar 9
- 0...700 bar 3
- 0...1000 bar 2
- 0...1600 bar 1
- 2...20 bar 1
- 10 bar 1
- 10 bar__6 bar__8 bar 6
- 20 bar 1
- 25 bar__40 bar 2
- 25 mbar 1
- 40...400 mbar 1
- 100 bar 1
- 250 bar 1
- 300 bar 1
- 350...400 bar 2
- -0.2...21 bar 1
- -0.2...400 bar 1
- -0.95...40 bar 1
- -0.95...60 bar 1
- -1...1 bar__0...2.000 bar 1
- -1...1 bar__0...2500 bar 1
- -1...2 bar__0...1000 bar 1
- -1...3 bar__0...700 bar 1
- -1...3 bar__0...1000 bar 1
- -1...10 bar__0...1000 bar 1
- -1...18 bar 1
- -1...60 bar 1
- -1...210 bar 2
- -1...250 bar 1
- -1...400 bar 1
- -1...1000 bar 1
- Corresponding to flange specification 1
- From 400 mbar depending on diameter of diaphragm 1
- PN 10 10
- PN 10 €“ 100; Class 150 - 600 1
- PN 16 8
- PN 25 5
- PN 50 2
-1...18 bar, 350...400 bar, 0...0.6 bar - 0...400 bar
6 items

990.15 Flanged Process Connection Diaphragm Seal
2282
Together with a block flange or a saddle flange, the WIKA 990.15 diaphragm seal forms a perfectly matched system. Through the process connection via block flanges or saddle flanges, compact assemblies can be optimally realised at the measuring point. Depending on customer requirements, the model 990.15 can be subsequently integrated into a process using the accessory models 910.19, 910.20 and 910.23. The process connection is designed as a flange connection. The measuring instrument is in a vertical position. Applications Specifically for connection with block flange or saddle flange and to combine with bourdon tube pressure gauges Suitable for corrosive, contaminated, hot or viscous pressure media Chemical and petrochemical industry
- USD

EXPD 920/924/932 Differential Pressostat
3989
The Trafag EXPD 920/924/932 ex differential pressostat electromechanical pressure switches provide high vibration resistance and switch point precision in combination with an extremely robust and durable design. This results in switches that can be operated for decades without requiring maintenance, even under harsh conditions. Various designs with bellows, membrane and piston sensors cover a wide variety of pressure ranges, media and load profiles for many different applications.
- USD

MBS 5100/5150 Pressure Transmitter
5154
The ship approved high accuracy Danfoss MBS 5100 and MBS 5150 block pressure transmitter is designed for use in almost all marine applications. The Danfoss MBS 5150 pressure transmitter with integrated pulse snubber is designed for use in marine applications with severe medium influences like cavitation, liquid hammer or pressure peaks and offers a reliable pressure measurement, even under harsh environmental conditions. The transmitters can be easily mounted directly on the MBV 5000 block test valve, or the threaded pressure connection can be used. The flexible pressure transmitter programme covers a 4 “ 20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0…1 to 0…400 bar with zero and span adjustment. Excellent vibration stability, robust construction, and a high degree of EMC / EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
- USD

MBS 8200/8250 Pressure Transmitter
5157
The Danfoss MBS 8200 pressure transmitters is developed to withstand the pressure pulsations and vibrations known in wind turbine applications. A new technology combining piezo resistive sensor element and programmable gain amplifiers makes the MBS 8200 the obvious choice for applications demanding the highest accuracy and insensitiveness against temperature variations. Further, this technology enhances functional safety by limiting the output signal at excess pressure conditions. It allows excellent sink/source capabilities. It leaves the pressure transmitters unaffected by electromagnetic fields up to 100 V/m. The Danfoss MBS 8250 pressure transmitter with integrated pulse-snubber is designed for use in hydraulic applications with severe media influences like cavitation, liquid hammer or pressure peaks and offers a reliable pressure measurement, even under harsh environmental conditions.
- USD

VZVA Positive Displacement Flow Sensor
7830
SIKA's gearwheel type VZVA positive displacement flow sensor records volume flows of liquids with both high and changing viscosities. The high-precision sensors work according to the displacement principle. The high resolution combined with reliable measurement accuracy makes the sensors especially useful for applications involving the measurement of small and minimal volumes. A very precisely adjusted gear pair within the casing forms the measuring element. The inflowing medium causes the gear pair to rotate. Contactless sensors scan the rotary motion. Since each tooth generates a pulse, this results in a very high resolution. Consequently, even the smallest volumes can be measured or dosed precisely. The measurement unit contains two pick-offs that are circumferentially offset by ¼ of a tooth pitch to generate a two-channel flow-proportional frequency signal. Suitable processing of the signal provides a higher resolution and the option to identify the flow direction. The maximum pressure drop should not exceed 16 bar. This limits the measurement range of high viscosity media (see pressure drop diagrams). The measurement accuracy increases with an increase in viscosity of the media.
- USD

VZGG Positive Displacement Flow Sensor
7835
SIKA™s gearwheel type VZGG positive displacement flow sensor records volume flows of liquids with both high and changing viscosities. The high-precision sensors work according to the displacement principle. The high resolution combined with reliable measurement accuracy makes the sensors especially useful for applications involving the measurement of small and minimal volumes. A very precisely adjusted gear pair within the casing forms the measuring element. The inflowing medium causes the gear pair to rotate. Contactless sensors scan the rotary motion. Since each tooth generates a pulse, this results in a very high resolution. Consequently, even the smallest volumes can be measured or dosed precisely. The measurement unit contains two pick-offs that are circumferentially offset by ¼ of a tooth pitch to generate a two-channel flow-proportional frequency signal. Suitable processing of the signal provides a higher resolution and the option to identify the flow direction. The maximum pressure drop should not exceed 16 bar. This limits the measurement range of high viscosity media (see pressure drop diagrams). The measurement accuracy increases with an increase in viscosity of the media.
- USD
1 - 6 of 6
1