close
Categories
Filter By
Company
Accuracy
Medium Temperature
Pressure Range
- 0...0.6 bar 1
- 0...0.6 bar__0...40 bar 5
- 0...0.6 bar__0...40 bar__PN 16/40 or Class 150/300 1
- 0...1.000 bar 1
- 0...1.000 mbar 1
- 0...1 bar__0...10 bar 1
- 0...1 bar__0...25 bar 1
- 0...1 bar__0...40 bar 1
- 0...10.000 bar 1
- 0...10 bar__0...600 bar 1
- 0...16 bar 1
- 0...25 bar 3
- 0...40 bar 1
- 0...60 bar 4
- 0...100 bar 1
- 0...250 bar 1
- 0...400 bar 2
- 0...600 bar 9
- 0...700 bar 3
- 0...1000 bar 2
- 0...1600 bar 1
- 2...20 bar 1
- 10 bar 1
- 10 bar__6 bar__8 bar 6
- 20 bar 1
- 25 bar__40 bar 2
- 25 mbar 1
- 40...400 mbar 1
- 100 bar 1
- 250 bar 1
- 300 bar 1
- 350...400 bar 2
- -0.2...21 bar 1
- -0.2...400 bar 1
- -0.95...40 bar 1
- -0.95...60 bar 1
- -1...1 bar__0...2.000 bar 1
- -1...1 bar__0...2500 bar 1
- -1...2 bar__0...1000 bar 1
- -1...3 bar__0...700 bar 1
- -1...3 bar__0...1000 bar 1
- -1...10 bar__0...1000 bar 1
- -1...18 bar 1
- -1...60 bar 1
- -1...210 bar 2
- -1...250 bar 1
- -1...400 bar 1
- -1...1000 bar 1
- Corresponding to flange specification 1
- From 400 mbar depending on diameter of diaphragm 1
- PN 10 10
- PN 10 €“ 100; Class 150 - 600 1
- PN 16 8
- PN 25 5
- PN 50 2
-1...1 bar__0...2500 bar, -1...1000 bar, 0...1600 bar, -1...210 bar - 10 bar__6 bar__8 bar
11 items

CPC4000 Pressure Controller
2693
The WIKA CPC4000 industrial pressure controller offers a broad pressure range from -1 ¦ 210 bar. This instrument is available as a desktop or as a 19″ rack-mounting kit. It can have up to two reference pressure sensors and an optional barometer for displaying barometric pressure or be used to emulate gauge or absolute pressure. Since the CPC4000 offers an accuracy of up to 0.02 % IS-50, and controls pressure with a high stability, it is particularly suited as a production tool for transmitter manufacturing, a calibration and maintenance tool for pressure measuring instruments or as a factory/working standard for the calibration of all types of pressure measuring instruments. The leak test and burst test special applications allow CPC4000 to be used as a pressure line testing equipment. The optional automatic contamination prevention system make the CPC4000 an ideal solution in oil and gas plants. Maximum ease-of-use is achieved through the touchscreen and the simple and intuitive menu navigation. In addition, the large number of menu languages add to its operability. The instrument can have up to two internal pressure sensors and the ranges for each reference pressure sensor are determined by the customer within the allowable range. Depending on the application, the operator can choose between three set-point entry methods: Direct entry of the pressure value (set point) which will be controlled via touchscreen keypad. Define steps to reach the desired pressure value by either defining fixed pressure increments or a percentage of span value. User-defined programmable test sequences.
- USD

D2 Digital Pressure Gauge
4883
The SIKA D2 digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA D2 digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. High accuracy in a signal acquisition is achieved by using high-performance measuring cells with electronic linearisation of the characteristic curve. Suitable instruments are available for a wide variety of measurement tasks. Ease of use is assured by innovative design and advanced technology. All essential functions for everyday use can be selected conveniently at the press of a button. Excellent protection against dust and moisture is provided by a membrane keypad or rubber buttons. Integrated supplementary functions make our digital pressure gauges true all-rounders. Display The large illuminated digital local display shows the measured pressure and indicates the current status of the digital pressure gauge, even under poor lighting conditions. This eliminates the difficult task of reading a dial gauge and avoiding parallax errors. Needle jitter due to vibration or pressure fluctuations is eliminated. Display damping or averaging can be configured directly using display filters. This ensures easy, tireless readout. Protection class High IP protection classes (IP67 (front) / IP67) are available to minimise dust and water sensitivity. Rugged, impact-resistant digital pressure gauges are fitted with rubber caps for protection during transport and field use. Battery operation / Auto-Off Power is supplied by long-life batteries (ordinary or rechargeable). An external AC adapter can also be used. To increase battery operating time, a Programmable Auto-Off function switches off the power to the instrument after prolonged inactivity. The electronics are designed for extremely low power consumption, which enables battery life of significantly more than 1500 hours.
- USD

Digital Pressure Gauge Type P
4886
The SIKA Type P digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA Type P digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. Linearisation Multi-point adjustment can be performed if it is necessary to adjust the indicated values at different test points. Two-point adjustment is available for setting the zero point and slope of the measuring cell curve. Type P digital pressure gauges allow up to six offset values to be programmed to shift the characteristic curve to meet the most stringent customer expectations. PC connection and software Many digital pressure gauges have a serial interface port to allow measurement values and stored data to be transferred directly to a PC and documented. An inexpensive measurement data acquisition system can easily be assembled with suitable software and an interface converter. Processes can be readily monitored and analysed using the recorded and visualised measurements, and all data can be exported using standard programs such as Microsoft Excel. Remote control is also possible. Various software packages with extensive recording and display functions, logger and alarm evaluation as well as for calibration are available. Analogue output An electrical output signal enables remote display on a control console or in a control room as well as the connection of external recorders and indicating instruments. Relay output Digital pressure gauges allow limit contacts to be closed even at low pressures. There is no need for high actuation forces for magnetic spring or inductive contacts, which makes it easier to signal critical equipment conditions and perform supplementary control tasks.
- USD

VMZ 25 Magnetic Inductive Flow Sensor
7633
The SIKA VMZ 25 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 25 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 25 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 20 Magnetic Inductive Flow Sensor
7637
The SIKA VMZ 20 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 20 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 20 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 15 Magnetic Inductive Flow Sensor
7639
The SIKA VMZ 15 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 15 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 15 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 08 Magnetic Inductive Flow Sensor
7641
The SIKA VMZ 08 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 08 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 08 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 06 Magnetic Inductive Flow Sensor
7643
The SIKA VMZ 06 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 06 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 06 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 03 Magnetic Inductive Flow Sensor
7645
The SIKA VMZ 03 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 03 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 03 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD