close
Categories
Filter By
Company
Connection Type
Medium Temperature
Pressure Range
- 0...0.6 bar 1
- 0...0.6 bar__0...40 bar 5
- 0...0.6 bar__0...40 bar__PN 16/40 or Class 150/300 1
- 0...1.000 bar 1
- 0...1.000 mbar 1
- 0...1 bar__0...10 bar 1
- 0...1 bar__0...25 bar 1
- 0...1 bar__0...40 bar 1
- 0...10.000 bar 1
- 0...10 bar__0...600 bar 1
- 0...16 bar 1
- 0...25 bar 3
- 0...40 bar 1
- 0...60 bar 4
- 0...100 bar 1
- 0...250 bar 1
- 0...400 bar 2
- 0...600 bar 9
- 0...700 bar 3
- 0...1000 bar 2
- 0...1600 bar 1
- 2...20 bar 1
- 10 bar 1
- 10 bar__6 bar__8 bar 6
- 20 bar 1
- 25 bar__40 bar 2
- 25 mbar 1
- 40...400 mbar 1
- 100 bar 1
- 250 bar 1
- 300 bar 1
- 350...400 bar 2
- -0.2...21 bar 1
- -0.2...400 bar 1
- -0.95...40 bar 1
- -0.95...60 bar 1
- -1...1 bar__0...2.000 bar 1
- -1...1 bar__0...2500 bar 1
- -1...2 bar__0...1000 bar 1
- -1...3 bar__0...700 bar 1
- -1...3 bar__0...1000 bar 1
- -1...10 bar__0...1000 bar 1
- -1...18 bar 1
- -1...60 bar 1
- -1...210 bar 2
- -1...250 bar 1
- -1...400 bar 1
- -1...1000 bar 1
- Corresponding to flange specification 1
- From 400 mbar depending on diameter of diaphragm 1
- PN 10 10
- PN 10 €“ 100; Class 150 - 600 1
- PN 16 8
- PN 25 5
- PN 50 2
-1...1 bar__0...2500 bar, -0.95...60 bar - 10 bar__6 bar__8 bar
8 items

P 60 Pneumatic Hand Test Pump
4871
The SIKA P 60 pneumatic hand test pump is designed to enable the direct connection of all pressure systems to be tested using adapters. The test sample is easily connected using the rugged industrial hose with integrated quick coupling and supplied adapters. The reference is fitted directly at the top of the pump using a positioning adapter. The required test pressure is initially generated using the handles and then adjusted precisely with the fine adjustment valve. As a result, the pressure on both instruments is the same. The pressure relief valve allows continuous pressure reduction and ensures accurate and easy testing, even with decreasing pressure. Air is used as pressure media. Especially in application areas in which wetting of the test sample is not allowed, or the use of aggressive or ionising substances must be avoided, air is the ideal test medium. SIKA˜s pneumatic test pump type P 60 fulfils requirements that in many cases can only be covered by several pumps from other suppliers. In the simplest case, the pressure is indicated by an analogue pressure gauge. An easy to read digital pressure gauge or hand-held instrument can also be used. The accuracy or adjustment of the pressure measuring device being tested can be checked by comparing the indicated reference value with the measured value for the device under test. OEM version and full version Depending on the model a matching pressure hose is part of the basic configuration of the OEM version of the test pump. The hydraulic hoses are fitted with a self-sealing quick coupling. Inch, conical or metric adapters for all commonly used connection threads are available in the full version. A matching seal kit is also included with the pump. All of the equipment is held in a carrying case with a foam-rubber insert.
- USD

Digital Pressure Gauge Type P
4886
The SIKA Type P digital pressure gauge is suitable for both stationary and mobile measurement and display of pressure. The SIKA Type P digital pressure gauge can be used as a reference to explain the checking, adjustment and calibration of other pressure measurement devices directly on-site. Linearisation Multi-point adjustment can be performed if it is necessary to adjust the indicated values at different test points. Two-point adjustment is available for setting the zero point and slope of the measuring cell curve. Type P digital pressure gauges allow up to six offset values to be programmed to shift the characteristic curve to meet the most stringent customer expectations. PC connection and software Many digital pressure gauges have a serial interface port to allow measurement values and stored data to be transferred directly to a PC and documented. An inexpensive measurement data acquisition system can easily be assembled with suitable software and an interface converter. Processes can be readily monitored and analysed using the recorded and visualised measurements, and all data can be exported using standard programs such as Microsoft Excel. Remote control is also possible. Various software packages with extensive recording and display functions, logger and alarm evaluation as well as for calibration are available. Analogue output An electrical output signal enables remote display on a control console or in a control room as well as the connection of external recorders and indicating instruments. Relay output Digital pressure gauges allow limit contacts to be closed even at low pressures. There is no need for high actuation forces for magnetic spring or inductive contacts, which makes it easier to signal critical equipment conditions and perform supplementary control tasks.
- USD

VMZ 25 Magnetic Inductive Flow Sensor
7633
The SIKA VMZ 25 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 25 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 25 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 20 Magnetic Inductive Flow Sensor
7637
The SIKA VMZ 20 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 20 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 20 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 15 Magnetic Inductive Flow Sensor
7639
The SIKA VMZ 15 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 15 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 15 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 08 Magnetic Inductive Flow Sensor
7641
The SIKA VMZ 08 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 08 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 08 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 06 Magnetic Inductive Flow Sensor
7643
The SIKA VMZ 06 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 06 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 06 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 03 Magnetic Inductive Flow Sensor
7645
The SIKA VMZ 03 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 03 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 03 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD
1 - 8 of 8
1