close
Filter By
Company
Ambient Temperature
Connection Type
Medium Temperature
Pressure Range
- 0...0.6 bar 1
- 0...0.6 bar__0...40 bar 5
- 0...0.6 bar__0...40 bar__PN 16/40 or Class 150/300 1
- 0...1.000 bar 1
- 0...1.000 mbar 1
- 0...1 bar__0...10 bar 1
- 0...1 bar__0...25 bar 1
- 0...1 bar__0...40 bar 1
- 0...10.000 bar 1
- 0...10 bar__0...600 bar 1
- 0...16 bar 1
- 0...25 bar 3
- 0...40 bar 1
- 0...60 bar 4
- 0...100 bar 1
- 0...250 bar 1
- 0...400 bar 2
- 0...600 bar 9
- 0...700 bar 3
- 0...1000 bar 2
- 0...1600 bar 1
- 2...20 bar 1
- 10 bar 1
- 10 bar__6 bar__8 bar 6
- 20 bar 1
- 25 bar__40 bar 2
- 25 mbar 1
- 40...400 mbar 1
- 100 bar 1
- 250 bar 1
- 300 bar 1
- 350...400 bar 2
- -0.2...21 bar 1
- -0.2...400 bar 1
- -0.95...40 bar 1
- -0.95...60 bar 1
- -1...1 bar__0...2.000 bar 1
- -1...1 bar__0...2500 bar 1
- -1...2 bar__0...1000 bar 1
- -1...3 bar__0...700 bar 1
- -1...3 bar__0...1000 bar 1
- -1...10 bar__0...1000 bar 1
- -1...18 bar 1
- -1...60 bar 1
- -1...210 bar 2
- -1...250 bar 1
- -1...400 bar 1
- -1...1000 bar 1
- Corresponding to flange specification 1
- From 400 mbar depending on diameter of diaphragm 1
- PN 10 10
- PN 10 €“ 100; Class 150 - 600 1
- PN 16 8
- PN 25 5
- PN 50 2
-0.2...21 bar, 2...20 bar - 10 bar__6 bar__8 bar
8 items

KP Pressure Switch
5288
The Danfoss KP pressure switches are used for regulating, monitoring and alarm systems in the industry. The KP pressure switches provide automatic limit protection or manual reset limit protection for pressure systems. The KP switches can be used with steam, air, gaseous and liquid media. The pressure switches are fitted with a single-pole changeover switch (SPDT). The position of the switch depends on the setting of the pressure switch and the pressure in the connector. Available types: KP 34 pressure switch KP 35 pressure switch KP 36 pressure switch KP 37 pressure switch KP 44 pressure switch
- USD

CS Pressure Switch
5294
The Danfoss CS pressure switch series has a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the range setting and adjustable differential. The Danfoss CS pressure switches are fitted with a manual switch that will lock the contact system in the open position independently of the pressure in the system. Pressure switches with relief valve are used in compressed air systems where pressure relief on the compressor piston before the start is required. The CS is suited for an automatic start and stop of air compressors and water boosters.
- USD

VMZ 25 Magnetic Inductive Flow Sensor
7633
The SIKA VMZ 25 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 25 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 25 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 20 Magnetic Inductive Flow Sensor
7637
The SIKA VMZ 20 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 20 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 20 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 15 Magnetic Inductive Flow Sensor
7639
The SIKA VMZ 15 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 15 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 15 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 08 Magnetic Inductive Flow Sensor
7641
The SIKA VMZ 08 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 08 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 08 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 06 Magnetic Inductive Flow Sensor
7643
The SIKA VMZ 06 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 06 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 06 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD

VMZ 03 Magnetic Inductive Flow Sensor
7645
The SIKA VMZ 03 magnetic inductive flow sensor for electrically conductive liquids is designed for OEM applications. Thanks to the use of cost-optimized plastic components, the SIKA VMZ 03 has a compact and lightweight design. The smart flow sensors of the SIKA VMZ 03 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
- USD
1 - 8 of 8
1