Filter Sort
close
Categories
Filter By
Company
Ambient Temperature
Material Spec
Nominal Pressure
1 - 6 of 6
SITRANS FC MASS 2100 DI 1.5

SITRANS FC MASS 2100 DI 1.5

3548

The SIEMENS SITRANS FC MASS 2100 DI 1.5 has demonstrated superior performance in numerous applications and field trials relating to mass flow- and density accuracy and turndown ratio. The single continuous tube design without internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food and beverage and pharmaceutical applications. The SITRANS F C MASS 2100 DI 1.5 is today the preferred meter for research and development and mini-plant applications for liquid or gas measurement, where measuring minimal quantities (e.g. drops per hour) is important. To make a complete flowmeter, the SITRANS F C MASS 2100 flow sensor must be combined with one of the following MASS transmitters: SIFLOW FC070 : For direct integration into SIMATIC based systems
View Details
SITRANS FC300 DN4

SITRANS FC300 DN4

3551

The SIEMENS SITRANS FC300 DN4 is a compact Coriolis mass flowmeter sensor suitable for flow measurement of all kind of liquids and gases. The sensor offers superior performance regarding flow accuracy, turn-down range and density accuracy. The single tube construction without internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability for food and beverage and pharmaceutical applications. The ease of installation through a Plug and Play interface ensures optimum performance and operation. Combined with the robust stainless steel encapsulation, the SITRANS FC300 sets new system integration standards and fits any process industry environment and application. To make a complete flowmeter, the SITRANS FC300 flow sensor must be combined with one of the following MASS transmitters: SITRANS FCT030 : For general industry applications SITRANS FCT010 : For OEMs and skids in applications where space is limited SITRANS FCT070 : For SIMATIC ET 200SP distributed I/O
View Details
SITRANS FC MASS 2100 DI 3-15

SITRANS FC MASS 2100 DI 3-15

3554

The SIEMENS SITRANS FC MASS 2100 DI 3-15 is suitable for accurate mass flow measurement for all kind of liquids and gases. The full bore design provides lower pressure loss due to the same internal diameter throughout the entire sensor. The single tube construction without internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability. The sensor is also characterised by having a large dynamic turn down range better than 500:1 and the market's thickest tube wall to ensure the highest integrity. Integral heating is optionally available to avoid sensitive fluids' solidification during downtime or period between discontinuing processes. To make a complete flowmeter, the SITRANS F C MASS 2100 flow sensor must be combined with one of the following MASS transmitters: SITRANS FCT030 : For general industry applications SITRANS FCT010 : For OEMs and skids in applications where space is limited SITRANS FCT070 : For SIMATIC ET 200SP distributed I/O
View Details
VHS Metal Level Switch

VHS Metal Level Switch

7859

The SIKA VHS level switch is a secure and reliable solution for monitoring fluid levels. The VHS level switch is installed at the side using G¾ or G½ thread sizes. The time-tested float principle and a potential-free contact as the signalling transmitter guarantee a high level of operational safety. The rising level in the tank forces the float up. Via paddle system, the magnet changes its position relative to Reed contact and actuates it. The repulsion between the two homopolar magnets and supports the buoyancy (Version VK… different). As soon as the level sinks again, the float follows also, and the magnet actuates the Reed contact again. Works adjusted switching function contact makes with a rising level contact opens with a falling level Can be changed by the customer. The Reed contact (3) used as signalling transmitter consists of two ferromagnetic contact-making tongues positioned in a shielding gas-filled glass bulb. As a result, burned contacts are virtually eliminated. This construction enables durability up to 100 000 000 switching cycles.
View Details
VH6 Metal Level Switch

VH6 Metal Level Switch

7868

The SIKA VH6 level switch is a secure and reliable solution for monitoring fluid levels. The VH6 level switch is installed at the side using G¾ or G½ thread sizes. The time-tested float principle and a potential-free contact as the signalling transmitter guarantee a high level of operational safety. The rising level in the tank forces the float up. Via paddle system, the magnet changes its position relative to Reed contact and actuates it. The repulsion between the two homopolar magnets and supports the buoyancy (Version VK… different). As soon as the level sinks again, the float follows also, and the magnet actuates the Reed contact again. Works adjusted switching function contact makes with a rising level contact opens with a falling level Can be changed by the customer. The Reed contact (3) used as signalling transmitter consists of two ferromagnetic contact-making tongues positioned in a shielding gas-filled glass bulb. As a result, burned contacts are virtually eliminated. This construction enables durability up to 100 000 000 switching cycles.
View Details
Extended Level Switch

Extended Level Switch

8957

The TUVO Instruments extended level switch is a secure and reliable solution for monitoring fluid levels. The extended level switch is installed at the side using G¾ or G½ thread sizes. The time-tested float principle and a potential-free contact as the signalling transmitter guarantee a high level of operational safety. The extended level switch can be customized up to the customer's wishes. By this unique feature of the extended floater, longer distances can be reached within the process or in a tank or basin. The floater is 3D printed so fully customisable to the customer's needs. The rising level in the tank forces the float up. Via paddle system, the magnet changes its position relative to Reed contact and actuates it. The repulsion between the two homopolar magnets and supports the buoyancy. As soon as the level sinks again, the float follows also, and the magnet actuates the Reed contact again. Works adjusted switching function Contact makes with a rising level Contact opens with a falling level
View Details
1 - 6 of 6