close
Filter By
Company
Accuracy
Ambient Temperature
Material Spec
Medium Temperature
- 0...20°C__0...60°C 1
- 0...50 °C 3
- 0...85°C 2
- 0...90°C 1
- 0...90°C__95°C 2
- 2€°200°C__ 150°C 1
- 5...60°C 1
- 10...100°C 1
- 30...100°C 2
- 60°C 7
- 80°C 2
- 120°C__30...100°C 1
- 200°C 1
- 200°C__Max. 100°C 4
- -10€°160°C 1
- -10...50°C 3
- -10...60°C 5
- -10...70 °C 1
- -10...90°C 5
- -10...120°C 1
- -20°200°C 1
- -20...60°C 1
- -20...70°C 1
- -20...70°C__0...70°C 1
- -20...80°C 3
- -20...85°C 1
- -20...90°C 3
- -20...100°C 3
- -20...110°C 1
- -20...130°C__-20...150°C 1
- -20...150°C 3
- -25...100°C 5
- -25...100°C__0...20°C 1
- -25...110°C 3
- -30...60°C 1
- -30...85°C 1
- -30...150°C 5
- -30...200°C 1
- -40°80°C 2
- -40...75°C 1
- -40...85°C 1
- -40...100°C 4
- -40...110°C 1
- -40...120°C 2
- -40...125°C 1
- -50°180°C 3
- Max. 60°C 4
- Max. 85°C 5
- Max. 100°C 17
- Max. 100°C__Max. 200°C 1
- Max. 110°C 3
- Max. 115°C 1
- Max. 120°C 1
- Max. 125°C  1
- Max. 150°C 1
- Max. 200°C 5
- O-Ring FKM: -15°C...150°C__O-Ring NBR: -30°C...100° 1
- see sealing material 1
Nominal Pressure
Switching Function
-40...75°C - Max. 110°C
4 items

E-10 / E-11 Pressure Transmitter
3067
The WIKA E-10 and E-11 flameproof pressure transmitters have been designed specifically for the high demands of industrial oil and gas applications. These pressure transmitters can be delivered with various analogue signals from 4 … 20 mA to a low-power version with DC 1 … 5 V. They feature exceptionally high resistance to vibration, pressure spikes and moisture ingress. Furthermore, these pressure transmitters fulfil IP 67 (NEMA 4x) ingress protection. On each instrument, comprehensive quality control and calibration is performed, so that an accuracy of 0.5 % can be ensured. Temperature compensation guarantees accuracy and long-term stability, even with strong fluctuations in the ambient temperature. The WIKA E-10 and E-11 are suitable for sour gas applications and feature particularly high resistance against sulphide stress cracking when in contact with sulphurous gases. The pressure transmitters are approved as œexplosion-proof for class I, II, III, div. 1 hazardous areas to FM and CSA as well as œflameproof for II 2 G Ex d II C to ATEX.
- USD

VHS Metal Level Switch
7859
The SIKA VHS level switch is a secure and reliable solution for monitoring fluid levels. The VHS level switch is installed at the side using G¾ or G½ thread sizes. The time-tested float principle and a potential-free contact as the signalling transmitter guarantee a high level of operational safety. The rising level in the tank forces the float up. Via paddle system, the magnet changes its position relative to Reed contact and actuates it. The repulsion between the two homopolar magnets and supports the buoyancy (Version VK… different). As soon as the level sinks again, the float follows also, and the magnet actuates the Reed contact again. Works adjusted switching function contact makes with a rising level contact opens with a falling level Can be changed by the customer. The Reed contact (3) used as signalling transmitter consists of two ferromagnetic contact-making tongues positioned in a shielding gas-filled glass bulb. As a result, burned contacts are virtually eliminated. This construction enables durability up to 100 000 000 switching cycles.
- USD

VH6 Metal Level Switch
7868
The SIKA VH6 level switch is a secure and reliable solution for monitoring fluid levels. The VH6 level switch is installed at the side using G¾ or G½ thread sizes. The time-tested float principle and a potential-free contact as the signalling transmitter guarantee a high level of operational safety. The rising level in the tank forces the float up. Via paddle system, the magnet changes its position relative to Reed contact and actuates it. The repulsion between the two homopolar magnets and supports the buoyancy (Version VK… different). As soon as the level sinks again, the float follows also, and the magnet actuates the Reed contact again. Works adjusted switching function contact makes with a rising level contact opens with a falling level Can be changed by the customer. The Reed contact (3) used as signalling transmitter consists of two ferromagnetic contact-making tongues positioned in a shielding gas-filled glass bulb. As a result, burned contacts are virtually eliminated. This construction enables durability up to 100 000 000 switching cycles.
- USD

Extended Level Switch
8957
The TUVO Instruments extended level switch is a secure and reliable solution for monitoring fluid levels. The extended level switch is installed at the side using G¾ or G½ thread sizes. The time-tested float principle and a potential-free contact as the signalling transmitter guarantee a high level of operational safety. The extended level switch can be customized up to the customer's wishes. By this unique feature of the extended floater, longer distances can be reached within the process or in a tank or basin. The floater is 3D printed so fully customisable to the customer's needs. The rising level in the tank forces the float up. Via paddle system, the magnet changes its position relative to Reed contact and actuates it. The repulsion between the two homopolar magnets and supports the buoyancy. As soon as the level sinks again, the float follows also, and the magnet actuates the Reed contact again. Works adjusted switching function Contact makes with a rising level Contact opens with a falling level
- USD