Filter Sort
close
Categories
Filter By
Company
Ambient Temperature
Measuring range
Nominal Size
Pressure Range
1 - 8 of 8
PG43SA-D Diaphragm Pressure Gauge

PG43SA-D Diaphragm Pressure Gauge

2811

The WIKA PG43SA-D pressure gauge has been designed specifically for the highest safety requirements in the pharmaceutical and biotechnology industries. Through its patented diaphragm monitoring, the risk of an undetected rupture of the diaphragm is eliminated since a red warning dot is immediately displayed on the dial. If this point on the dial remains white, then the pressure element is intact, and cost-intensive maintenance on the measuring point is not required. In the event of a diaphragm rupture, a second barrier in the pressure measuring instrument ensures the reliable separation of ambience and process. The diaphragm pressure gauge transmits the pressure, purely mechanically and without transmission fluid, from the process to the pressure element. Due to their thickness, the diaphragm elements are very robust and have high overpressure safety, ensuring a safe pressure measurement without any risk of contamination. The flush welded diaphragm element in conjunction with the aseptic process connections enables a dead-space free connection to the process. The independent pressure display, needing no external power, finds applications with the processing and transport of high-quality and critical media, for example on portable tanks.WIKA's PG43SA-D in hygienic design can be used for CIP (cleaning in place) and SIP (sterilisation in place) and in wash-down areas, or it can be completely sterilised in an autoclave. The measuring instrument can thus be cleaned reliably and time-efficiently. The model PG43SA-D conforms to the 3-A Sanitary Standard and is certified by EHEDG.
View Details
SITRANS F M MAG 1100 F

SITRANS F M MAG 1100 F

3500

The SIEMENS SITRANS F M MAG 1100 F sensor is specially designed for the food and beverage, and pharmaceutical industries and is available with hygienic and flexible process connections. It meets all sanitary requirements and is 3A certified and EHEDG approved. To have a complete flowmeter, please combine it with one of the following MAG transmitters: SITRANS F M MAG 5000 SITRANS F M MAG 6000 SITRANS F M MAG 6000 I
View Details
VHS Flow Switch

VHS Flow Switch

7589

The SIKA VHS flow switches are used for monitoring volume flows. Depending on conditions, the SIKA VHS flow switch is available for various nominal widths and set-point ranges. The SIKA VHS flow switch contains a paddle system to whose end a permanent magnet is attached. Above this magnet is a reed contact, located outside the flow of fluid. A second magnet creates the force necessary to reset the switch back to the no-flow position. When the flow being monitored pushes against the paddle system, the paddle swings away. This changes the position of the magnet in relation to the reed contact and thus activates the connection. As soon as the flow is interrupted, the paddle moves back to its starting position, thus activating the reed contact once again. The force necessary to push the magnet back is provided by the two magnets repelling each other. Using magnetic force instead of the usual leaf spring means that the switch is considerably more stable in the long term and much less sensitive to pressure peaks.
View Details
VHS09 Flow Switch

VHS09 Flow Switch

7600

The SIKA VHS09 flow switches are used for monitoring volume flows. Depending on conditions, the SIKA VHS09 flow switch is available for various nominal widths and set-point ranges. The SIKA VHS09 flow switch contains a paddle system to whose end a permanent magnet is attached. Above this magnet is a reed contact, located outside the flow of fluid. A second magnet creates the force necessary to reset the switch back to the no-flow position. When the flow being monitored pushes against the paddle system, the paddle swings away. This changes the position of the magnet in relation to the reed contact and thus activates the connection. As soon as the flow is interrupted, the paddle moves back to its starting position, thus activating the reed contact once again. The force necessary to push the magnet back is provided by the two magnets repelling each other. Using magnetic force instead of the usual leaf spring means that the switch is considerably more stable in the long term and much less sensitive to pressure peaks.
View Details
VHS06 Flow Switch

VHS06 Flow Switch

7604

The SIKA VHS06 flow switches are used for monitoring volume flows. Depending on conditions, the SIKA VHS06 flow switch is available for various nominal widths and set-point ranges. The SIKA VHS06 flow switch contains a paddle system to whose end a permanent magnet is attached. Above this magnet is a reed contact, located outside the flow of fluid. A second magnet creates the force necessary to reset the switch back to the no-flow position. When the flow being monitored pushes against the paddle system, the paddle swings away. This changes the position of the magnet in relation to the reed contact and thus activates the connection. As soon as the flow is interrupted, the paddle moves back to its starting position, thus activating the reed contact once again. The force necessary to push the magnet back is provided by the two magnets repelling each other. Using magnetic force instead of the usual leaf spring means that the switch is considerably more stable in the long term and much less sensitive to pressure peaks.
View Details
RLS-1000 Float Switch

RLS-1000 Float Switch

8111

The WIKA RLS-1000 float switch is a robust, reliable and inexpensive float switch. The monitoring of levels, as well as dry-run protection and overflow protection, are cost-sensitive applications in the machine-building industry, therefore a float switch is a perfect solution for many plants. The RLS-1000 float switch offers reliable measurements for the level in vessels with water, oil, diesel or other liquids by means of a permanent magnet and frictionless reed contacts at max. 4 defined switch points and can be used in a medium temperature range from -30 to +150 °C (-22 to +302 °F). The WIKA RLS-1000 float switch is simple, easy to use and fast to integrate because it does not need to be calibrated or set during the installation. This greatly improves the ease of handling, especially in confined installation situations. Also, since its robust design makes it resistant to vibrations and shocks, maintenance costs are minimal.
View Details
RLS-3000 Float Switch

RLS-3000 Float Switch

8118

The WIKA RLS-3000 float switch with temperature output combines the measurement of the level and temperature of liquids in a single measuring point. The RLS-3000 float switch is suitable for a multitude of media, for example, oil, water, diesel and refrigerants, due to the stainless steel used. A permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contacts built into the guide tube. The triggering of the reed contacts by the permanent magnet is contact-free and thus free from wear. The switching functions of normally open, normally closed or change-over can be realised for the defined liquid level. The additional temperature output enables the medium temperature to be monitored by means of a preconfigured bimetal temperature switch or a Pt100/Pt1000 resistance signal.
View Details
RLS-4000 Float Switch

RLS-4000 Float Switch

8122

The WIKA RLS-4000 float switch with optional temperature output has been designed for the measurement of level and temperature at hazardous measuring points. The WIKA RLS-4000 float switch is suitable for a multitude of media, for example, oil, water, diesel and refrigerants, thanks to the stainless steel used. A permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contacts built into the guide tube. The triggering of the reed contacts by the permanent magnet is contact-free and thus free from wear. The switching functions of normally open, normally closed or change-over can be realised for the defined liquid level. The optional temperature output enables the medium temperature to be monitored by means of a preconfigured bimetal temperature switch or a Pt100/Pt1000 resistance signal.
View Details
1 - 8 of 8
1