Measuring range
Medium Temperature
- 0...20°C__0...60°C 1
- 0...50 °C 3
- 0...85°C 2
- 0...90°C 1
- 0...90°C__95°C 2
- 2€°200°C__ 150°C 1
- 5...60°C 1
- 10...100°C 1
- 30...100°C 2
- 60°C 7
- 80°C 2
- 120°C__30...100°C 1
- 200°C 1
- 200°C__Max. 100°C 4
- -10€°160°C 1
- -10...50°C 3
- -10...60°C 5
- -10...70 °C 1
- -10...90°C 5
- -10...120°C 1
- -20°200°C 1
- -20...60°C 1
- -20...70°C 1
- -20...70°C__0...70°C 1
- -20...80°C 3
- -20...85°C 1
- -20...90°C 3
- -20...100°C 3
- -20...110°C 1
- -20...130°C__-20...150°C 1
- -20...150°C 3
- -25...100°C 5
- -25...100°C__0...20°C 1
- -25...110°C 3
- -30...60°C 1
- -30...85°C 1
- -30...150°C 5
- -30...200°C 1
- -40°80°C 2
- -40...75°C 1
- -40...85°C 1
- -40...100°C 4
- -40...110°C 1
- -40...120°C 2
- -40...125°C 1
- -50°180°C 3
- Max. 60°C 4
- Max. 85°C 5
- Max. 100°C 17
- Max. 100°C__Max. 200°C 1
- Max. 110°C 3
- Max. 115°C 1
- Max. 120°C 1
- Max. 125°C  1
- Max. 150°C 1
- Max. 200°C 5
- O-Ring FKM: -15°C...150°C__O-Ring NBR: -30°C...100° 1
- see sealing material 1
Nominal Size
-20...150°C - -20...100°C
6 items

DPGT43.100 / 43.160 Pressure Gauge
1507
At any point where a differential pressure has to be indicated locally, and, at the same time, a signal is wanted to be transmitted to a central controller or remote control room, the WIKA DPGT43.100 / 43.160 intelliGAUGE can be used. Through the combination of a high-quality mechanical measuring system and precise electronic signal processing, the process pressure can be read securely, even if the power supply is lost. An additional measuring point for mechanical pressure indication can thus be saved. The WIKA DPGT43.100/43.160 is based upon a model 732.51 high quality, stainless steel pressure gauge with a nominal size of 100 or 160. The pressure gauge is manufactured by EN 837-3. These differential pressure gauges are made of highly corrosion-resistant stainless steel and feature an all-metal media chamber sealing. Therefore no elastomer sealing elements are required so that a better long-term leak tightness is ensured. A high overpressure safety is achieved by the all-metal construction and the close-fitting design of the measuring element. The rugged design of the diaphragm measuring system produces a pointer rotation proportional to the pressure. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft – it is a non-contact sensor and therefore completely free from wear and friction. From this, the electrical output signal proportional to the pressure, e.g. 4 … 20 mA, is produced. The electronic WIKA transmitter, integrated into the high-quality mechanical differential pressure gauge, combines the advantages of electrical signal transmission with the advantages of a local mechanical display. The measuring span (electrical output signal) is set automatically along with the mechanical display, i.e. the scale over the full display range corresponds to 4 … 20 mA. The electrical zero point can also be set manually.
- USD

PG43SA-S Pressure Gauge
2753
The WIKA PG43SA pressure gauge is designed for the requirements of sanitary applications. The purely mechanical pressure transmission, using the diaphragm-element measuring principle, and the high overpressure safety ensure a safe pressure measurement. As a result of the dry measuring cell, the risk of contamination of the product by transmission fluid is eliminated. The flush welded diaphragm element in conjunction with the aseptic process connections (e.g. clamp, threaded, VARIVENT®, BioControl®) enables a dead-space free connection to the process. The pressure gauge finds applications, for example, in systems for ultrapure steam generation or as an independent pressure display, without the need for an external power supply, on portable tanks. The PG43SA-S in hygienic design can be used for CIP (cleaning in place) and SIP (sterilisation in place) and in wash-down areas. The measuring instrument can thus be cleaned reliably and time-efficiently. At an easily accessible point on the top of the case, the zero point can be easily corrected. Based on a third-party verification, WIKA's model PG43SA-S corresponds to the 3-A Sanitary Standard. A variety of 3.1 and 2.2 certificates are available for GMP-compliant documentation, such as a material certificate or the list of single measured values.
- USD

SA-11 Pressure Transmitter
3276
The WIKA SA-11 pressure transmitter is designed especially for the requirements of the food and beverage, pharmaceutical and biotechnology industries. It is particularly suitable for the special conditions of CIP/SIP cleaning processes, such as chemical stability towards cleaning liquids and high temperatures. The flush diaphragm is directly welded to the process connection. This guarantees a crevice-free connection of the process connection and the measuring cell so that additional sealings are not required. For dead-space free instrumentation, aseptic process connections (clamp, threaded, VARIVENT ® and NEUMO®) are available. The WIKA SA-11 pressure transmitter is ideally suited to fulfil the stringent demands of sanitary applications and is EHEDG certified. Furthermore, the SA-11 is marked with the 3-A symbol and current version number, as it conforms, based on a third-party verification, to the 3-A standard. The SA-11 pressure transmitter is powered with a DC voltage of 10 (14) … 30 V. Available electronic output signals are 4 … 20 mA, 0 … 20 mA or 0 … 10 V output. A stainless steel case with an ingress protection of up to IP 68 offers a secure protection for external cleaning with splashed water and enables its use in high-humidity environments. Through the integrated cooling section, process temperatures of up to 150 °C can be realised.
- USD

DPGT43HP.100 / 43HP.160 Pressure Gauge
3358
At any point where a differential pressure has to be indicated locally, and, at the same time, a signal is wanted to be transmitted to a central controller or remote control room, the WIKA DPGT43HP.100 / 43HP.160 intelliGAUGE (patent applied for, among others European Patent No. EP 06113003) can be used. The electronic WIKA transmitter, integrated into the model 732.14 high-quality mechanical differential pressure gauge, combines the advantages of electrical signal transmission with the benefits of a local mechanical display. The model DPGT43 is based upon a model 732.14 high-quality, stainless steel pressure gauge with a nominal size of 100 or 160. The pressure measuring instrument is manufactured in accordance with EN 837-3. The use of high-quality stainless steel materials and the robust design are geared to applications in the chemical and process engineering industries. Thus the instrument is suitable for liquid and gaseous media, also in aggressive environments. A high overload safety is achieved by the all-metal construction and the close-fitting design of the pressure element. The robust diaphragm measuring system produces a pointer rotation proportional to the pressure. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft “ it is a non-contact sensor and therefore completely free from wear and friction. From this, the electrical output signal, proportional to the pressure, of 4 … 20 mA, is produced. In addition, the electrical zero point can be set manually. The electronic WIKA sensor, integrated into the high-quality mechanical differential pressure gauge, combines the advantages of electrical signal transmission with a local mechanical display that remains readable during a power failure. An additional measuring point with a mechanical pressure display can thus be saved.
- USD

IPT-20 / 21 Process Transmitter
7101
With its 4 … 20 mA, 4 … 20 mA HART®, PROFIBUS® PA or FOUNDATION Fieldbus„¢ output signals, combined with either intrinsic safety or flameproof enclosure ignition protection type (in accordance with ATEX and IECEx), the WIKA IPT-20 / 21 is ideally suited to applications with the highest demands on the measurement technology. Versatile in application As a result of the available measuring ranges of 0 … 0.1 bar to 0 … 4,000 bar (0 … 0.15 to 0 … 60,000 psi) and a freely selectable turndown, the instrument can be used in almost any application. A large number of process connections and the extensive possibilities offered by the metallic measuring cell enable use in all industries. There are seven different case variants available, and thus it is possible to select a variant suited to every operating environment. The case itself can be rotated through 330° and is available in plastic, aluminium and stainless steel. An electropolished stainless steel case (316L) is available to meet the high demands of the food and pharmaceutical industries. Easy configuration and operation Service and configuration at the instrument are carried out using the optional display and operating module, which can be fitted in four positions. The operating menu has a simple and self-explanatory structure and has nine selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware„¢ free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into corresponding process control systems.
- USD

DPGS43.1x0 Differential Pressure Gauge
7159
Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the WIKA DPGS43.100 or DPGS43.160 switchGAUGE finds its use. Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the pointer position of the pressure gauge. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window. Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The differential pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.
- USD
1 - 6 of 6