DPGS40 Pressure Gauge

DPGS40 Pressure Gauge

1513

The WIKA DPGS40 differential pressure gauges of the DELTA-line product family are primarily used for the monitoring and control of low differential pressures where there are high requirements regarding one-sided overpressure and static pressure. Typical markets for these products are the shipbuilding industry, process heating technology, the heating, ventilation and air-conditioning industries, the water/wastewater industry, and machine building and plant construction. For these, the primary function of the measuring instruments is the monitoring of filters, compressors and pumps. Wherever a differential pressure must be displayed locally and, at the same time, electrical circuits need to be switched safely dependent on defined differential pressure, the DELTA-comb finds its use. As the pressure passes above or below a defined set point, the switching operation is triggered. The switch point is accessible from the front and can be adjusted in the range of 10 … 100 % of the full-scale value. An assistant scale enables an accurate setting of the switch point and indicates the current set point. Often in these applications, alongside the display of the differential pressure, the current working pressure is also relevant. For this reason, a working pressure indication is integrated within the DELTA-comb differential pressure switch as standard. The two local, easily readable, mechanical displays need no power supply and enable the simultaneous reading of the working and the differential pressure. Furthermore, this saves on an additional measuring and sealing point, reducing additional expense for piping and mounting. The robust aluminium case and shatterproof window enable an extended service life of the product, even under harsh ambient conditions. As a result of the small measuring range of 0 ¦ 250 mbar, the instrument can also be used for applications with low differential pressures.
View Details
DPGS40 TA Pressure Gauge

DPGS40 TA Pressure Gauge

3325

The WIKA DPGS40 TA differential pressure gauges of the DELTA-line product family are primarily used for the monitoring and control of low differential pressures where there are high requirements regarding one-sided overpressure and static pressure. Typical markets for these products are the shipbuilding industry, process heating technology, the heating, ventilation and air-conditioning industries, the water/wastewater industry, and machine building and plant construction. For these, the primary function of the measuring instruments is the monitoring of filters, compressors and pumps. Wherever a differential pressure must be displayed locally and, at the same time, electrical circuits need to be switched safely dependent on defined differential pressure, the DELTA-comb finds its use. As the pressure passes above or below a defined set point, the switching operation is triggered. The switch point is accessible from the front and can be adjusted in the range of 10 … 100 % of the full-scale value. An assistant scale enables an accurate setting of the switch point and indicates the current set point. Due to the mechanical indication, the differential pressure can be read securely, even if the voltage supply is lost. A unique feature of the DELTA-comb with component testing lies in approval of the Germanischer Lloyd. This approval is a seal of quality in the shipping and offshore industries and ensures safe operation. The robust aluminium case and shatterproof window enable a long service life of the product, even under harsh ambient conditions. As a result of the low measuring range of 0 ¦ 250 mbar, the instrument can also be used for applications with low differential pressures.
View Details
DPS40 Pressure Switch

DPS40 Pressure Switch

3334

The WIKA DPS40 differential pressure gauges of the DELTA-line product family are primarily used for the monitoring and control of low differential pressures where there are high requirements regarding one-sided overpressure and static pressure. Typical markets for these products are the shipbuilding industry, process heating technology, the heating, ventilation and air-conditioning industries, the water/wastewater industry, and machine building and plant construction. For these, the main function of the measuring instruments is the monitoring and control of filters, compressors and pumps. Wherever electrical circuits need to be switched safely dependent on defined differential pressure, the DELTA-switch finds its use. As the pressure passes above or below a defined set point, the switching operation is triggered. The switch point is accessible from the front and can be set in the range of 10 … 100 % of the full-scale value. An assistance scale enables an accurate setting of the switch point and indicates the current set point. The robust aluminium case and shatterproof window enable a long service life of the product, even under harsh ambient conditions. This ensures that there is no danger from the instrument and it is resistant to external mechanical impacts. Besides, ingress protection of IP65 protects the unit against ingress from dust and spray water. As a result of the low measuring range of 0 ¦ 250 mbar, the instrument can also be used for applications with low differential pressures.
View Details
DPGT40 Differential Pressure Sensor

DPGT40 Differential Pressure Sensor

3361

The WIKA DPGT40 differential pressure gauges of the DELTA-line product family are primarily used for the monitoring of low differential pressures where there are high requirements regarding one-sided overpressure and static pressure. Typical markets for these products are the shipbuilding industry, process heating technology, the heating, ventilation and air-conditioning industries, the water/wastewater industry, and machine building and plant construction. For these, the main function of the measuring instruments is the monitoring of filters, compressors and pumps. Wherever a signal transmission is needed and, at the same time, a differential pressure must be displayed locally, and the DELTA-trans differential pressure sensor finds its use. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft – it is a non-contact sensor and therefore completely free from wear and friction. From this, the electrical output signal proportional to the pressure, e.g. 4 … 20 mA, is produced, which then acts to transmit the signal to the control room. In addition, the electrical zero point can be set manually. Often in these applications, alongside the display of the differential pressure, the current working pressure is also relevant. For this reason, a working pressure indication is integrated within the DELTA-trans differential pressure sensor as standard. The two local, easily readable, mechanical displays need no power supply and enable the simultaneous reading of the working and the differential pressure. Furthermore, this saves on an additional measuring and sealing point, reducing additional expense for piping and mounting. The robust aluminium case and shatterproof window enable a long service life of the product, even under harsh ambient conditions. This ensures that there is no danger from the instrument and it is resistant to external mechanical impacts.
View Details
DPG40 Differential Pressure Gauge

DPG40 Differential Pressure Gauge

6965

The WIAK DPG40 differential pressure gauge of the DELTA-line product family are primarily used for the monitoring of low differential pressures where there are high requirements in terms of one-sided overpressure and static pressure. Typical markets for these products are the shipbuilding industry, process heating technology, the heating, ventilation and air-conditioning industries, the waster/wastewater industry, and machine building and plant construction. For these, the main function of the measuring instruments is the monitoring of filters, compressors and pumps. Often in these applications, alongside the display of the differential pressure, the current working pressure is also relevant. For this reason, a working pressure indication is integrated within the DELTA-plus differential pressure gauge as standard. The two local, easily readable, mechanical displays enable the simultaneous reading of the working and the differential pressure. Furthermore, this saves on an additional measuring and sealing point, reducing additional expense for piping and mounting. The robust aluminium case and shatterproof window enable a long service life of the product, even under harsh ambient conditions. As a result of the low-pressure range of 0 ¦ 160 mbar, the instrument can also be used for applications with low differential pressures. A further key feature is the high accuracy of up to 1.6 %, which is essential for most applications. The new and functional design completes the appearance of the measuring instrument.
View Details
VMI 20 Magnetic Inductive Flow Sensor

VMI 20 Magnetic Inductive Flow Sensor

7647

Due to the robust metal housing and stable metal process connections, the SIKA VMI 20 is ideal for use in the field of mechanical engineering and plant construction. Its design also makes it suitable for higher temperatures and process pressures, and the instrument is available in three different sizes. All sensors will be delivered with a works calibration certificate. The smart flow sensors of the SIKA VMI 20 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
VMI 10 Magnetic Inductive Flow Sensor

VMI 10 Magnetic Inductive Flow Sensor

7649

Due to the robust metal housing and stable metal process connections, the SIKA VMI 10 is ideal for use in the field of mechanical engineering and plant construction. Its design also makes it suitable for higher temperatures and process pressures, and the instrument is available in three different sizes. All sensors will be delivered with a works calibration certificate. The smart flow sensors of the SIKA VMI 10 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
VMI 07 Magnetic Inductive Flow Sensor

VMI 07 Magnetic Inductive Flow Sensor

7651

Due to the robust metal housing and stable metal process connections, the SIKA VMI 07 is ideal for use in the field of mechanical engineering and plant construction. Its design also makes it suitable for higher temperatures and process pressures, and the instrument is available in three different sizes. All sensors will be delivered with a works calibration certificate. The smart flow sensors of the SIKA VMI 07 induQ® series operate according to the principle of induction: The measuring pipe is in a magnetic field (B). If an electrically conductive medium, with the flow (Q) to be measured, flows through the measuring pipe and thereby at a right-angle to the magnetic field, a voltage (U) is induced in the medium. This voltage is proportional to the average flow velocity and is picked up by two electrodes. Regarding flow proportional output signals, two versions are available: Frequency output signal (standard) Analog and frequency output signal (option) The pulse rate can be configured at the factory. The induQ® sensors enable the flow measurement/volume flow measurement or dosing of electrically conductive liquids without any moving parts. They are the ideal flow sensors when accuracy and reliability are a must.
View Details
1 - 8 of 8