close
Filter By
Company
Ambient Temperature
Measuring range
- 0...0.1 bar__0...2 bar 1
- 0...0.1 bar__0...10 bar 1
- 0...0.1 bar__0...25 bar 2
- 0...0.1 bar__0...250 bar 1
- 0...0.1 bar__0...1000 bar 1
- 0...0.2 bar__0...10 bar 1
- 0...0.4 bar__0...2000 bar 1
- 0...1.6 bar__0...320 bar 1
- 0...1.6 bar__0...600 bar 1
- 0...1.25 mbar__0...32 bar 1
- 0...1 bar__0...16 bar 1
- 0...1 bar__0...600 bar 1
- 0...1 mbar__0...700 bar 2
- 0...1 mH2O__0...40 mH2O 1
- 0...2.5 bar__0...250 bar 1
- 0...2.5 bar__0...600 bar 2
- 0...2.5 bar__0...2500 bar 1
- 0...2.5 mbar 1
- 0...4 bar__2...25 bar 1
- 0...6 bar__0...600 bar 1
- 0...10.000 Pa 1
- 0...10 m/s 2
- 0...10 mbar__0...400 bar 1
- 0...20 mH2O__0...3 mH2O 1
- 0...25 bar 1
- 0...30 kg/h (0 to 66 lb/h) 1
- 0...160 bar__0...2.5 mbar 1
- 0...350 kg/h (0 to 772 lb/h) 1
- 0...360 bar 1
- 0...600°C 1
- 0...5600 kg/h (0 to 12345 lb/h) 1
- 1...10 bar__10...100 bar 1
- 1...10 bar__40...400 bar 1
- 1...10 bar__60...600 bar 2
- 30...150°C 2
- -0.6...3.4 bar__4...40 bar 1
- -0.6...3.4 bar__40...400 bar 3
- -0.9...1.5 bar__10...100 bar 1
- -1...6 bar__-1...8 bar 1
- -1...18 bar 1
- -1...18 bar__-1...6 bar 1
- -40...40 bar__-500...500 mbar 1
- -40...800°C 1
- -50...200°C 4
- -50...400°C 1
- -50...550°C 1
- -50...600°C 1
- -50...800°C 1
- -200...800°C 1
- -250°7.500 Pa 1
- On request 1
- Qn 10...2200 m³/h 1
- Qn 28...4200 m³/h 1
- Qp 15...36000 m³/h 1
- See Datasheet (Downloads) 1
Medium Temperature
30...150°C, 1...10 bar__40...400 bar - -40...40 bar__-500...500 mbar
4 items

DPT-10 Pressure Transmitter
1503
With its 4 … 20 mA, 4 … 20 mA HART®, PROFIBUS® PA or FOUNDATION Fieldbus„¢ output signals, combined with either intrinsically-safe or flameproof ignition protection (in accordance with ATEX), the WIKA DPT-10 differential pressure transmitter is ideally suited to applications requiring these features. The electronics of all transmitters with explosion protection, even for the flameproof variant, are intrinsically safe. Thus it is possible to make adjustments on the instrument in EX areas while the instrument is live. The WIKA DPT-10 is suitable for many industrial measuring requirements, such as flow measurement using differential pressure elements, level measurement or filter and pump monitoring. With diaphragm seals fitted, the DPT-10 differential pressure transmitter is also suitable for harsh process conditions. As a result of the available measuring ranges of 0 … 10 mbar up to 0 … 40 bar and a static pressure limitation of up to 420 bar, the instrument can be used in almost any application. The internal digital signal processing, combined with proven sensors, guarantees high accuracy and the best long-term stability. There are seven different housing variants available for the DPT-10 differential pressure transmitter, and thus, it is possible to select a variant suited to every operating environment. The housing itself can be rotated through 330° and is available in plastic, aluminium and stainless steel. An electropolished stainless steel housing (316L) is available to meet the high demands of the food industry and the pharmaceutical industry. Easy configuration and operation Service and set up at the DPT-10 differential pressure transmitter are carried out using the optional display and operation module, which can be fitted in four positions. The operation menu has a simple and self-explanatory structure and has nine selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware„¢ free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into a corresponding Distributed Control Systems.
- USD

PST4K 9K4 Picostat Pressure Switch
4014
The Trafag PST4K 9K4 of the Picostat series is based on Trafag's long lasting experience in the shipbuilding and railway sector. This further improved version offers high vibration resistance within a compact body and is suitable for a wide temperature range.
- USD

RLS-3000 Float Switch
8118
The WIKA RLS-3000 float switch with temperature output combines the measurement of the level and temperature of liquids in a single measuring point. The RLS-3000 float switch is suitable for a multitude of media, for example, oil, water, diesel and refrigerants, due to the stainless steel used. A permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contacts built into the guide tube. The triggering of the reed contacts by the permanent magnet is contact-free and thus free from wear. The switching functions of normally open, normally closed or change-over can be realised for the defined liquid level. The additional temperature output enables the medium temperature to be monitored by means of a preconfigured bimetal temperature switch or a Pt100/Pt1000 resistance signal.
- USD

RLS-4000 Float Switch
8122
The WIKA RLS-4000 float switch with optional temperature output has been designed for the measurement of level and temperature at hazardous measuring points. The WIKA RLS-4000 float switch is suitable for a multitude of media, for example, oil, water, diesel and refrigerants, thanks to the stainless steel used. A permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contacts built into the guide tube. The triggering of the reed contacts by the permanent magnet is contact-free and thus free from wear. The switching functions of normally open, normally closed or change-over can be realised for the defined liquid level. The optional temperature output enables the medium temperature to be monitored by means of a preconfigured bimetal temperature switch or a Pt100/Pt1000 resistance signal.
- USD
1 - 4 of 4
1