close
Categories
Filter By
Company
Connection Type
Insertion Length
Measuring range
- 0...0.1 bar__0...2 bar 1
- 0...0.1 bar__0...10 bar 1
- 0...0.1 bar__0...25 bar 2
- 0...0.1 bar__0...250 bar 1
- 0...0.1 bar__0...1000 bar 1
- 0...0.2 bar__0...10 bar 1
- 0...0.4 bar__0...2000 bar 1
- 0...1.6 bar__0...320 bar 1
- 0...1.6 bar__0...600 bar 1
- 0...1.25 mbar__0...32 bar 1
- 0...1 bar__0...16 bar 1
- 0...1 bar__0...600 bar 1
- 0...1 mbar__0...700 bar 2
- 0...1 mH2O__0...40 mH2O 1
- 0...2.5 bar__0...250 bar 1
- 0...2.5 bar__0...600 bar 2
- 0...2.5 bar__0...2500 bar 1
- 0...2.5 mbar 1
- 0...4 bar__2...25 bar 1
- 0...6 bar__0...600 bar 1
- 0...10.000 Pa 1
- 0...10 m/s 2
- 0...10 mbar__0...400 bar 1
- 0...20 mH2O__0...3 mH2O 1
- 0...25 bar 1
- 0...30 kg/h (0 to 66 lb/h) 1
- 0...160 bar__0...2.5 mbar 1
- 0...350 kg/h (0 to 772 lb/h) 1
- 0...360 bar 1
- 0...600°C 1
- 0...5600 kg/h (0 to 12345 lb/h) 1
- 1...10 bar__10...100 bar 1
- 1...10 bar__40...400 bar 1
- 1...10 bar__60...600 bar 2
- 30...150°C 2
- -0.6...3.4 bar__4...40 bar 1
- -0.6...3.4 bar__40...400 bar 3
- -0.9...1.5 bar__10...100 bar 1
- -1...6 bar__-1...8 bar 1
- -1...18 bar 1
- -1...18 bar__-1...6 bar 1
- -40...40 bar__-500...500 mbar 1
- -40...800°C 1
- -50...200°C 4
- -50...400°C 1
- -50...550°C 1
- -50...600°C 1
- -50...800°C 1
- -200...800°C 1
- -250°7.500 Pa 1
- On request 1
- Qn 10...2200 m³/h 1
- Qn 28...4200 m³/h 1
- Qp 15...36000 m³/h 1
- See Datasheet (Downloads) 1
0...600°C, 0...1.6 bar__0...600 bar, On request - -50...200°C
7 items

T91.x Analogue Temperature Transmitter
3096
The WIKA T91.x analogue temperature transmitter is matched to the specific requirements of the industry. Depending on the output signal, they are particularly suitable for direct connection to evaluation instruments with voltage or current inputs such as PLC's or AD conversion cards in PCs. The WIKA T91.10, T91.20 and T91.30 analogue temperature transmitter convert the temperature-dependent change in resistance of resistance thermometers or the temperature-dependent voltage change in thermocouples into a 0 … 10 V or 4 … 20 mA output signal. With these standardised signals, the measured temperature values can be transmitted directly and safely. The temperature transmitters of the T91 model series are fixed-range transmitters which are supplied with the necessary measuring ranges in line with the customer's requirements. A later fine adjustment of the zero point and the span can be made with potentiometers once fitted.
- USD

T16 Digital Temperature Transmitter
3911
The WIKA T16 Digital Temperature Transmitter is designed for universal use in plant and machine building, and also in the process industry. The WIKA T16 digital temperature transmitter offers high accuracy and excellent protection against electromagnetic influences (EMI). Via the WIKAsoft-TT configuration software and the model PU-448 programming unit, the T16 temperature transmitter can be parameterised very easily, quickly and with a clear overview. Besides the selection of the sensor type and the measuring range, the software enables the error signalling operation, damping, several measuring point descriptions and process adjustment to be stored. Furthermore, the WIKAsoft-TT software offers a line recording functionality where the temperature profile for the thermocouple connected to the T16 can be displayed. The WIKA T16 digital transmitter features various supervisory functionality, such as sensor break detection and monitoring of the measuring range. Moreover, these transmitters have comprehensive cyclic self-monitoring functionality.
- USD

H 8212/8213 Pressure Transmitter
3921
The Trafag H 8212/8213 pressure transmitter is used for electronically measuring and evaluating pressure. Over the decades, Trafag pressure transmitters have proven themselves in a multitude of demanding applications in harsh environments. They are available in many different designs to suit pressure and electrical connections, measuring procedures, electrical output signals and certifications (CE, EX, rail and ship). Excellent technology and precise manufacturing ensure that the transmitters work correctly, especially in areas where high requirements are placed on long-term stability, vibration resistance, electromagnetic compatibility, shock resistance or temperature insensitivity.
- USD

MBT 153 Temperature Sensor
5193
The Danfoss MBT 153 is a universal cable temperature sensor used to control cooling water and ventilation systems within general industry applications. The MBT 153 temperature sensor is based on a standardized Pt 100 or Pt 1000 element, which gives a reliable and accurate measurement. On request, Danfoss can also deliver the MBT 153 sensor with NTC / PTC elements. The sensor is based on a stainless steel housing with a cable, making the sensor extremely flexible. The MBT 153 can be combined with a sensor pocket, type MBT 120, to protect the silicone cable from the media. The sensor combined with the sensor pocket is named MBT 5253. The MBT 153 has a PVC or silicone cable as standard, but it can be delivered with teflon cable on request.
- USD

MBT 5310 Temperature Sensor
5219
The Danfoss MBT 5310 temperature sensor is designed for measuring the temperature in bearings where there is a risk of overheating. To get a short reaction time, the measuring element is placed to secure a reaction time of down to t0.5 = 6 sec. in water. The MBT 5310 is fitted with an adjustable spring-loaded protection tube which ensures metallic contact between bearing and sensor at all times.
- USD

MBT 5560 Temperature Sensor
5225
With the MBT 5560 temperature sensor, Danfoss has combined the technology of its standard temperature sensors and the electrical connections from their MBS pressure transmitters with newly developed electronics which has resulted in a compact temperature sensor with a built-in transmitter. The Danfoss MBT 5560 is designed for use in harsh industrial environments where reliable, robust and accurate equipment is required. Available with a wide selection of process and electrical connections. Can be delivered with a 33 mm extension length which makes it possible to measure temperatures up to 200 °C without damaging the built-in electronics.
- USD

MBT 5722 Temperature Sensor
5228
The Danfoss MBT 5722 temperature sensor is designed especially for monitoring bearing temperature in stern tubes: Flexible protection tube that makes it possible to reach bearings placed up to 20 m from the terminal box. Precision Pt 100 element secures fast and precise caption of the bearing temperature, making it possible to prevent bearing damage.
- USD
1 - 7 of 7
1