close
Categories
Filter By
Company
Measuring range
- 0...0.1 bar__0...2 bar 1
- 0...0.1 bar__0...10 bar 1
- 0...0.1 bar__0...25 bar 2
- 0...0.1 bar__0...250 bar 1
- 0...0.1 bar__0...1000 bar 1
- 0...0.2 bar__0...10 bar 1
- 0...0.4 bar__0...2000 bar 1
- 0...1.6 bar__0...320 bar 1
- 0...1.6 bar__0...600 bar 1
- 0...1.25 mbar__0...32 bar 1
- 0...1 bar__0...16 bar 1
- 0...1 bar__0...600 bar 1
- 0...1 mbar__0...700 bar 2
- 0...1 mH2O__0...40 mH2O 1
- 0...2.5 bar__0...250 bar 1
- 0...2.5 bar__0...600 bar 2
- 0...2.5 bar__0...2500 bar 1
- 0...2.5 mbar 1
- 0...4 bar__2...25 bar 1
- 0...6 bar__0...600 bar 1
- 0...10.000 Pa 1
- 0...10 m/s 2
- 0...10 mbar__0...400 bar 1
- 0...20 mH2O__0...3 mH2O 1
- 0...25 bar 1
- 0...30 kg/h (0 to 66 lb/h) 1
- 0...160 bar__0...2.5 mbar 1
- 0...350 kg/h (0 to 772 lb/h) 1
- 0...360 bar 1
- 0...600°C 1
- 0...5600 kg/h (0 to 12345 lb/h) 1
- 1...10 bar__10...100 bar 1
- 1...10 bar__40...400 bar 1
- 1...10 bar__60...600 bar 2
- 30...150°C 2
- -0.6...3.4 bar__4...40 bar 1
- -0.6...3.4 bar__40...400 bar 3
- -0.9...1.5 bar__10...100 bar 1
- -1...6 bar__-1...8 bar 1
- -1...18 bar 1
- -1...18 bar__-1...6 bar 1
- -40...40 bar__-500...500 mbar 1
- -40...800°C 1
- -50...200°C 4
- -50...400°C 1
- -50...550°C 1
- -50...600°C 1
- -50...800°C 1
- -200...800°C 1
- -250°7.500 Pa 1
- On request 1
- Qn 10...2200 m³/h 1
- Qn 28...4200 m³/h 1
- Qp 15...36000 m³/h 1
- See Datasheet (Downloads) 1
Medium Temperature
0...1.25 mbar__0...32 bar, 30...150°C - On request
4 items

T91.x Analogue Temperature Transmitter
3096
The WIKA T91.x analogue temperature transmitter is matched to the specific requirements of the industry. Depending on the output signal, they are particularly suitable for direct connection to evaluation instruments with voltage or current inputs such as PLC's or AD conversion cards in PCs. The WIKA T91.10, T91.20 and T91.30 analogue temperature transmitter convert the temperature-dependent change in resistance of resistance thermometers or the temperature-dependent voltage change in thermocouples into a 0 … 10 V or 4 … 20 mA output signal. With these standardised signals, the measured temperature values can be transmitted directly and safely. The temperature transmitters of the T91 model series are fixed-range transmitters which are supplied with the necessary measuring ranges in line with the customer's requirements. A later fine adjustment of the zero point and the span can be made with potentiometers once fitted.
- USD

SITRANS P500
3422
The SIEMENS SITRANS P500 has been developed to meet the highest expectations for measuring accuracy, ruggedness, and user-friendliness, and it merges seamlessly into the SITRANS P family. With the SITRANS P500, you can expect pressure measurement at the highest level. The SIEMENS SITRANS P500 guarantees an accuracy of ‰¤ 0.03 % as well as outstanding values for the influence of static pressure and temperature on the measured result. In this way, it guarantees a total performance of ‰¤ 0.09 % up to a turndown of 10:1. Since this feature means that only one measuring cell can be used for different measuring ranges, inventory costs can be significantly reduced without the need for losses in the quality of the measured result. The high long-term stability of the sensor also reduces maintenance costs thanks to extended calibration intervals and ensures that you can always rely on the measured results in the long term. An innovative sensor assembly enables direct-connected use in process temperatures of up to 125 °C (257 °F) even without a remote seal system. With an improved 3-pushbutton operator input concept for setting the device, the SITRANS P500˜s host of diagnostics options can be used conveniently without software. Even curve displays and trend diagrams can be represented on display for user-friendly process monitoring. SITRANS P500 is also suitable for use in safety instrumented systems SIL2 according to IEC 61508 / 61511. The P500 is available with either die-cast aluminium housing or stainless steel 316L housing.
- USD

RLS-3000 Float Switch
8118
The WIKA RLS-3000 float switch with temperature output combines the measurement of the level and temperature of liquids in a single measuring point. The RLS-3000 float switch is suitable for a multitude of media, for example, oil, water, diesel and refrigerants, due to the stainless steel used. A permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contacts built into the guide tube. The triggering of the reed contacts by the permanent magnet is contact-free and thus free from wear. The switching functions of normally open, normally closed or change-over can be realised for the defined liquid level. The additional temperature output enables the medium temperature to be monitored by means of a preconfigured bimetal temperature switch or a Pt100/Pt1000 resistance signal.
- USD

RLS-4000 Float Switch
8122
The WIKA RLS-4000 float switch with optional temperature output has been designed for the measurement of level and temperature at hazardous measuring points. The WIKA RLS-4000 float switch is suitable for a multitude of media, for example, oil, water, diesel and refrigerants, thanks to the stainless steel used. A permanent magnet built into the float triggers, with its magnetic field, the potential-free reed contacts built into the guide tube. The triggering of the reed contacts by the permanent magnet is contact-free and thus free from wear. The switching functions of normally open, normally closed or change-over can be realised for the defined liquid level. The optional temperature output enables the medium temperature to be monitored by means of a preconfigured bimetal temperature switch or a Pt100/Pt1000 resistance signal.
- USD
1 - 4 of 4
1