close
Categories
Filter By
Company
Approvals
Connection Type
Measuring range
- 0...0.1 bar__0...2 bar 1
- 0...0.1 bar__0...10 bar 1
- 0...0.1 bar__0...25 bar 2
- 0...0.1 bar__0...250 bar 1
- 0...0.1 bar__0...1000 bar 1
- 0...0.2 bar__0...10 bar 1
- 0...0.4 bar__0...2000 bar 1
- 0...1.6 bar__0...320 bar 1
- 0...1.6 bar__0...600 bar 1
- 0...1.25 mbar__0...32 bar 1
- 0...1 bar__0...16 bar 1
- 0...1 bar__0...600 bar 1
- 0...1 mbar__0...700 bar 2
- 0...1 mH2O__0...40 mH2O 1
- 0...2.5 bar__0...250 bar 1
- 0...2.5 bar__0...600 bar 2
- 0...2.5 bar__0...2500 bar 1
- 0...2.5 mbar 1
- 0...4 bar__2...25 bar 1
- 0...6 bar__0...600 bar 1
- 0...10.000 Pa 1
- 0...10 m/s 2
- 0...10 mbar__0...400 bar 1
- 0...20 mH2O__0...3 mH2O 1
- 0...25 bar 1
- 0...30 kg/h (0 to 66 lb/h) 1
- 0...160 bar__0...2.5 mbar 1
- 0...350 kg/h (0 to 772 lb/h) 1
- 0...360 bar 1
- 0...600°C 1
- 0...5600 kg/h (0 to 12345 lb/h) 1
- 1...10 bar__10...100 bar 1
- 1...10 bar__40...400 bar 1
- 1...10 bar__60...600 bar 2
- 30...150°C 2
- -0.6...3.4 bar__4...40 bar 1
- -0.6...3.4 bar__40...400 bar 3
- -0.9...1.5 bar__10...100 bar 1
- -1...6 bar__-1...8 bar 1
- -1...18 bar 1
- -1...18 bar__-1...6 bar 1
- -40...40 bar__-500...500 mbar 1
- -40...800°C 1
- -50...200°C 4
- -50...400°C 1
- -50...550°C 1
- -50...600°C 1
- -50...800°C 1
- -200...800°C 1
- -250°7.500 Pa 1
- On request 1
- Qn 10...2200 m³/h 1
- Qn 28...4200 m³/h 1
- Qp 15...36000 m³/h 1
- See Datasheet (Downloads) 1
Medium Temperature
Nominal Pressure
Nominal Size
-200...800°C - 0...5600 kg/h (0 to 12345 lb/h)
2 items

SITRANS FC MASS 2100 DI 3-15
3554
The SIEMENS SITRANS FC MASS 2100 DI 3-15 is suitable for accurate mass flow measurement for all kind of liquids and gases. The full bore design provides lower pressure loss due to the same internal diameter throughout the entire sensor. The single tube construction without internal welds, reductions or flow splitters offers optimal hygiene, safety and CIP cleanability. The sensor is also characterised by having a large dynamic turn down range better than 500:1 and the market's thickest tube wall to ensure the highest integrity. Integral heating is optionally available to avoid sensitive fluids' solidification during downtime or period between discontinuing processes. To make a complete flowmeter, the SITRANS F C MASS 2100 flow sensor must be combined with one of the following MASS transmitters: SITRANS FCT030 : For general industry applications SITRANS FCT010 : For OEMs and skids in applications where space is limited SITRANS FCT070 : For SIMATIC ET 200SP distributed I/O
- USD

MBT 9110 Temperature Transmitter
5231
The Danfoss MBT 9110 temperature transmitter can be used for converting the Pt 100 / Pt 1000 ohm signal or the thermocouple mV signal to a 4 “ 20 mA signal. The Danfoss MBT 9110 is a very durable and reliable temperature transmitter with all major marine approvals and can be used together with all our sensors based on Pt or Thermocouple technology. The MBT 9110 transmitters in the standard program are delivered in an enclosure but are also used as an integrated part of certain temperature sensors. The transmitter is available as standard or galvanic isolated with or without EEx approval.
- USD
1 - 2 of 2
1