close
Categories
Filter By
Company
Ambient Temperature
Connection Type
- 1/4 NPT-F 1
- 1/4 NPT-F__Adapter 1/2 NPT-F__Adapter 1/2 NPT-M 1
- 1 NPT__½ NPT__¾ NPT 1
- 1 NPT__G ½ B__G ¾ B male__½ NPT__¾ NPT 1
- 2-wire 1
- 2-wire__3-wire__4-wire 8
- 2-wire__3-wire__4-wire__G ¼__G ½__G…œ__M10 x 1__M14×1.5 1
- 2x 3-wire__3-wire__4-wire 1
- 2 x G ¼ B female__2 x G ½ B male__½ NPT male 1
- 2 x G ¼ female__2 x ¼ NPT female 2
- 2 x G ¼ female__Centre distance 26 mm__In-line__Lower 1
- 2 x G½ female, lower mount (LM) 1
- 3-wire__4-wire 1
- 14 mm flats lower mount 1
- 9/16 - 18 UNF (female)__M16 x 1.5 (female)__M20 x 1. 1
- 5/8 - 18 UNF (female)__9/16 - 18 UNF (female)__G ½__M 1
- 5/8 - 18 UNF x 27 (female)__9/16 - 18 UNF (female)__ 1
- 19 mm flats__2 x G 3/8 B (male)__Back mount__Lower mo 1
- 7/16-20 UNF 2B Schrader female 1
- 7/16-20 UNF BOSS__G¼ B EN 837 1
- 22 mm flats__G ½ 1
- 25.4...49.5 mm 1
- 26.7 mm__33.4 mm__48.3 mm 1
- 40 mm__50 mm 1
- ¼ NPT female 1
- ANSI Flange__DIN Flange 1
- ANSI Flange__Flange 4
- Back connection 1
- Back mount__G ½__Lower mount 1
- Back mount__Thermowell G½ B 1
- BSP ISO 228__NPT__ DN 50 1
- Butt Weld 2
- Clamp connection per DIN 32676 / ISO 2852 / BS4825 1
- Copper alloy, lower mount (LM) G 1/4 B (male), 14 1
- DIN 11864 1
- DN 100__DN 25__DN 40__DN 50__DN 80 1
- Flange 17
- Flange__G ¼__G ¼ A__G ½ A__¼ NPT female__½ NPT 1
- Flange__G…›__G…œ 1
- Flange__Screwed 1
- Flanged 74
- G 1/4 (female)__G 1/4 (male) 1
- G 1 1
- G 1„8__G ¼ 2
- G 1„8__G ¼__M10 x 1__R 1/8__¼ NPT__…› NPT 2
- G 1¼ 1
- G 1¼ male thread 2
- G 1__G 1„8 1
- G1__G2__G¼__G½__G¾ 1
- G 1__G 2__G ¼__G ½__G…œ 1
- G1__G¼__G½__G¾ 2
- G 1__M33 x 2 1
- G1 B__G½ B__M20 x 1.5__Push-in/weld-in__½ NPT 1
- G1 female__G¾ B__M20 x 1.5 male 1
- G1-ISO 228 male 1
- G 1 male thread 1
- G1 male thread 2
- G2 2
- G¼ 4
- G ¼...G 1 2
- G¼ / H16 UNF 1
- G¼__G¼ A__G½ A__M20 x 1.5__¼ NPT female__½ NPT 1
- G ¼__G¾ 1
- G¼__G…› 1
- G ¼__SW 14 1
- G¼__SW 14 1
- G¼ A DIN 3852-E__¼ NPT 1
- G¼ A DIN 3852-E__sealing FKM/FPM 1
- G¼ B (male)__G½ B (male)__SW14__SW22 1
- G ¼ B (male)__Stainless steel 316L 1
- G ¼ B (male)__SW 14 1
- G¼ B (NS63)__G½ B (NS80, 100) 1
- G ¼ B__G …› B__¼ NPT__…› NPT 1
- G ¼ B female__G ½ B male__½ NPT male 1
- G ¼ female__G ½ female 1
- G ½ 1
- G½ 4
- G ½...G 2 2
- G ½__G¼ 1
- G ½__G¼__M20 x 1.5__½ NPT 1
- G ½__G¼__SW 14__SW 17__SW 22 1
- G ½__G¾ 1
- G½__G¾__M20 x 1.5__M27 x 2 4
- G ½__G¾__M24x2 1
- G½__G…œ__M20 x 1.5 2
- G ½__Lower mount__SW22 1
- G ½__Lower mount__SW 27 1
- G ½__SW 22 1
- G ½ B 2
- G ½ B (lower mount) 1
- G½ B (male)__Stainless steel 316L__SW 22 1
- G ½ B__¼ NPT__½ NPT 1
- G ½ B__½ NPT__½ NPT female 1
- G½ B__G¾ B male 1
- G ½ B__M20 x 1.5__½ NPT 1
- G ½ B female__G ½ B male__½ NPT male 1
- G ½ B male__SW 22 1
- G ½ B thread 1
- G½-ISO 228 male 1
- G½-ISO 228 male__G¾-ISO 228 1
- G½ male 1
- G¾ 5
- G…œ 1
- G …œ...G 1 1
- JIS flange 4
- Lower mount__¼ NPT female 1
- NS 40: G 1/8 B (male) NS 50, 63: G 1/4 B (male), 1
- Pipe adapter 1
- Rp 1/2__Rp 3/4 1
- Rp - female thread cylindrical (BSPT) 1
- Socket Weld 3
- Stainless steel 1
- Surface mounting 1
- Threaded 15
- UExSC 1
- UExUE 1
- Union End Sil Braze 9
- Union nut 1
- Via subplate with lateral female thread connection 2
Filling
Insertion Length
Medium Temperature
Nominal Size
25.4...49.5 mm - G ½ B (lower mount)
2 items

TW25 Thermowell
3146
Each thermowell is an essential component of any temperature measurement point. The WIKA TW25 thermowell is used to separate the process from the surrounding area, thus protecting the environment and operating personnel and keeps aggressive media, high pressures and flow rates from the temperature sensor itself and thereby enables the thermometer to be exchanged during operation. Based on the almost limitless application possibilities, there are a large number of variants, such as thermowell designs or materials. The type of process connection and the primary method of manufacture are critical design differentiation criteria. A necessary differentiation can be made between threaded and weld-in thermowells, and those with flange connections. Furthermore, one can differentiate between fabricated and solid-machined thermowells. Fabricated thermowells are constructed from a tube, that is closed at the tip by a welded solid tip. Solid-machined thermowells are manufactured from barstock. The WIKA TW25 series of solid-machined thermowells with flange connection are suitable for use with numerous electrical and mechanical thermometers from WIKA. Due to the heavy-duty design, these international design thermowells are the first choice for use the chemical and petrochemical industries and in plant construction. This thermowell can also be ordered with the innovative ScrutonWell® design. The added helical shape on the outside of the insert increases the thermowell™s resistance to the Kármán vortex street and the stress this causes on the instrument by breaking the vortex up into smaller vortices. By incorporating the helix onto the outside of the thermowell, the Scrutonwell® design reduces oscillation by more than 90%!
- USD

332.30 / 333.30 Test gauge
6939
The WIKA 332.30 / 333.30 high-quality test gauge has been specifically designed for increased safety requirements during high-accuracy pressure measurements and is suited for calibration tasks. With an accuracy class of 0.6 %, the Bourdon tube pressure gauge is suitable for testing industrial type pressure gauges or for precision measurement in laboratories. Optionally, an accuracy class of 0.25 % is possible for pressures up to 400 bar. The wear-resistant precision movement, the wetted parts and the case are made from high-grade stainless steel. WIKA manufactures and qualifies the Bourdon tube pressure gauge in accordance with the requirements of the EN 837-1 European standard in the S3 safety version. The safety version is made up of a non-splintering window, a solid baffle wall between measuring system and dial and a blow-out back. In the event of a failure, the operator is protected at the front side, as media or components can only be ejected via the back of the case. For harsh operating conditions (e.g. vibrations), all instruments are also available with an optional liquid filling. The optimal readability of the instrument, with a nominal size of 160 mm, is achieved via a knife-edge pointer and a dial with fine divisions. Supported through the optional mirror band scale, the parallax error can be eliminated.
- USD
1 - 2 of 2
1