close
Categories
Filter By
Company
Connection Type
- 1/4 NPT-F 1
- 1/4 NPT-F__Adapter 1/2 NPT-F__Adapter 1/2 NPT-M 1
- 1 NPT__½ NPT__¾ NPT 1
- 1 NPT__G ½ B__G ¾ B male__½ NPT__¾ NPT 1
- 2-wire 1
- 2-wire__3-wire__4-wire 8
- 2-wire__3-wire__4-wire__G ¼__G ½__G…œ__M10 x 1__M14×1.5 1
- 2x 3-wire__3-wire__4-wire 1
- 2 x G ¼ B female__2 x G ½ B male__½ NPT male 1
- 2 x G ¼ female__2 x ¼ NPT female 2
- 2 x G ¼ female__Centre distance 26 mm__In-line__Lower 1
- 2 x G½ female, lower mount (LM) 1
- 3-wire__4-wire 1
- 14 mm flats lower mount 1
- 9/16 - 18 UNF (female)__M16 x 1.5 (female)__M20 x 1. 1
- 5/8 - 18 UNF (female)__9/16 - 18 UNF (female)__G ½__M 1
- 5/8 - 18 UNF x 27 (female)__9/16 - 18 UNF (female)__ 1
- 19 mm flats__2 x G 3/8 B (male)__Back mount__Lower mo 1
- 7/16-20 UNF 2B Schrader female 1
- 7/16-20 UNF BOSS__G¼ B EN 837 1
- 22 mm flats__G ½ 1
- 25.4...49.5 mm 1
- 26.7 mm__33.4 mm__48.3 mm 1
- 40 mm__50 mm 1
- ¼ NPT female 1
- ANSI Flange__DIN Flange 1
- ANSI Flange__Flange 4
- Back connection 1
- Back mount__G ½__Lower mount 1
- Back mount__Thermowell G½ B 1
- BSP ISO 228__NPT__ DN 50 1
- Butt Weld 2
- Clamp connection per DIN 32676 / ISO 2852 / BS4825 1
- Copper alloy, lower mount (LM) G 1/4 B (male), 14 1
- DIN 11864 1
- DN 100__DN 25__DN 40__DN 50__DN 80 1
- Flange 17
- Flange__G ¼__G ¼ A__G ½ A__¼ NPT female__½ NPT 1
- Flange__G…›__G…œ 1
- Flange__Screwed 1
- Flanged 74
- G 1/4 (female)__G 1/4 (male) 1
- G 1 1
- G 1„8__G ¼ 2
- G 1„8__G ¼__M10 x 1__R 1/8__¼ NPT__…› NPT 2
- G 1¼ 1
- G 1¼ male thread 2
- G 1__G 1„8 1
- G1__G2__G¼__G½__G¾ 1
- G 1__G 2__G ¼__G ½__G…œ 1
- G1__G¼__G½__G¾ 2
- G 1__M33 x 2 1
- G1 B__G½ B__M20 x 1.5__Push-in/weld-in__½ NPT 1
- G1 female__G¾ B__M20 x 1.5 male 1
- G1-ISO 228 male 1
- G 1 male thread 1
- G1 male thread 2
- G2 2
- G¼ 4
- G ¼...G 1 2
- G¼ / H16 UNF 1
- G¼__G¼ A__G½ A__M20 x 1.5__¼ NPT female__½ NPT 1
- G ¼__G¾ 1
- G¼__G…› 1
- G ¼__SW 14 1
- G¼__SW 14 1
- G¼ A DIN 3852-E__¼ NPT 1
- G¼ A DIN 3852-E__sealing FKM/FPM 1
- G¼ B (male)__G½ B (male)__SW14__SW22 1
- G ¼ B (male)__Stainless steel 316L 1
- G ¼ B (male)__SW 14 1
- G¼ B (NS63)__G½ B (NS80, 100) 1
- G ¼ B__G …› B__¼ NPT__…› NPT 1
- G ¼ B female__G ½ B male__½ NPT male 1
- G ¼ female__G ½ female 1
- G ½ 1
- G½ 4
- G ½...G 2 2
- G ½__G¼ 1
- G ½__G¼__M20 x 1.5__½ NPT 1
- G ½__G¼__SW 14__SW 17__SW 22 1
- G ½__G¾ 1
- G½__G¾__M20 x 1.5__M27 x 2 4
- G ½__G¾__M24x2 1
- G½__G…œ__M20 x 1.5 2
- G ½__Lower mount__SW22 1
- G ½__Lower mount__SW 27 1
- G ½__SW 22 1
- G ½ B 2
- G ½ B (lower mount) 1
- G½ B (male)__Stainless steel 316L__SW 22 1
- G ½ B__¼ NPT__½ NPT 1
- G ½ B__½ NPT__½ NPT female 1
- G½ B__G¾ B male 1
- G ½ B__M20 x 1.5__½ NPT 1
- G ½ B female__G ½ B male__½ NPT male 1
- G ½ B male__SW 22 1
- G ½ B thread 1
- G½-ISO 228 male 1
- G½-ISO 228 male__G¾-ISO 228 1
- G½ male 1
- G¾ 5
- G…œ 1
- G …œ...G 1 1
- JIS flange 4
- Lower mount__¼ NPT female 1
- NS 40: G 1/8 B (male) NS 50, 63: G 1/4 B (male), 1
- Pipe adapter 1
- Rp 1/2__Rp 3/4 1
- Rp - female thread cylindrical (BSPT) 1
- Socket Weld 3
- Stainless steel 1
- Surface mounting 1
- Threaded 15
- UExSC 1
- UExUE 1
- Union End Sil Braze 9
- Union nut 1
- Via subplate with lateral female thread connection 2
Insertion Length
Material Spec
Temperature Range
2-wire - 26.7 mm__33.4 mm__48.3 mm
2 items

TW20 Thermowell
3140
Each thermowell is an essential component of any temperature measurement point. The WIKA TW20 thermowell is used to separate the process from the surrounding area, thus protecting the environment and operating personnel and keeps aggressive media, high pressures and flow rates from the temperature sensor itself and thereby enables the thermometer to be exchanged during operation. Based on the almost limitless application possibilities, there are a large number of variants, such as thermowell designs or materials. The type of process connection and the primary method of manufacture are critical design differentiation criteria. A necessary differentiation can be made between threaded and weld-in thermowells, and those with flange connections. Furthermore, one can differentiate between fabricated and solid-machined thermowells. Fabricated thermowells are constructed from a tube, that is closed at the tip by a welded solid tip. Solid-machined thermowells are manufactured from bar stock. The WIKA TW20 series of solid-machined thermowells with flange connection are suitable for use with numerous electrical and mechanical thermometers from WIKA. Due to the heavy-duty design, these international design thermowells are the first choice to use the chemical and petrochemical industries and in plant construction. This thermowell can also be ordered with the innovative ScrutonWell® design. The added helical shape on the outside of the insert increases the thermowell™s resistance to the Kármán vortex street and the stress this causes on the instrument by breaking the vortex up into smaller vortices. By incorporating the helix onto the outside of the thermowell, the Scrutonwell® design reduces oscillation by more than 90%!
- USD

TR34 Miniature Resistance Thermometer
4337
The WIKA TR34 miniature resistance thermometer is used as universal thermometers for the measurement of liquid and gaseous media in the range -50 … +250 °C (-58 … +482 °F). The instruments are intrinsically safe and suitable for use in hazardous areas. The WIKA TR34 can be used for pressures up to 140 bar with 3 mm sensor diameters and up to 270 bar with 6 mm sensor diameters, depending on the instrument version. All electrical components are protected against humidity (IP67 or IP69K) and designed to withstand vibration (20 g, depending on instrument version). The resistance thermometer is available with direct sensor output or integrated transmitter, which can be configured individually via the PC configuration software WIKAsoft-TT. Measuring range, damping, fault signal per NAMUR NE43 and TAG no. can be adjusted. Insertion length, process connection, sensor and connection method can each be selected for the respective application within the order information. The WIKA TR34 resistance thermometer consists of a thermowell with a fixed process connection and is screwed directly into the process. The electrical connection is made via an M12 x 1 circular connector. An adapter for electrical connection with angular connector per DIN EN 175301-803 is optionally available (industrial property rights registered under No. 001370985).
- USD
1 - 2 of 2
1