close
Filter By
Company
Connection Type
- 1/4 NPT-F 1
- 1/4 NPT-F__Adapter 1/2 NPT-F__Adapter 1/2 NPT-M 1
- 1 NPT__½ NPT__¾ NPT 1
- 1 NPT__G ½ B__G ¾ B male__½ NPT__¾ NPT 1
- 2-wire 1
- 2-wire__3-wire__4-wire 8
- 2-wire__3-wire__4-wire__G ¼__G ½__G…œ__M10 x 1__M14×1.5 1
- 2x 3-wire__3-wire__4-wire 1
- 2 x G ¼ B female__2 x G ½ B male__½ NPT male 1
- 2 x G ¼ female__2 x ¼ NPT female 2
- 2 x G ¼ female__Centre distance 26 mm__In-line__Lower 1
- 2 x G½ female, lower mount (LM) 1
- 3-wire__4-wire 1
- 14 mm flats lower mount 1
- 9/16 - 18 UNF (female)__M16 x 1.5 (female)__M20 x 1. 1
- 5/8 - 18 UNF (female)__9/16 - 18 UNF (female)__G ½__M 1
- 5/8 - 18 UNF x 27 (female)__9/16 - 18 UNF (female)__ 1
- 19 mm flats__2 x G 3/8 B (male)__Back mount__Lower mo 1
- 7/16-20 UNF 2B Schrader female 1
- 7/16-20 UNF BOSS__G¼ B EN 837 1
- 22 mm flats__G ½ 1
- 25.4...49.5 mm 1
- 26.7 mm__33.4 mm__48.3 mm 1
- 40 mm__50 mm 1
- ¼ NPT female 1
- ANSI Flange__DIN Flange 1
- ANSI Flange__Flange 4
- Back connection 1
- Back mount__G ½__Lower mount 1
- Back mount__Thermowell G½ B 1
- BSP ISO 228__NPT__ DN 50 1
- Butt Weld 2
- Clamp connection per DIN 32676 / ISO 2852 / BS4825 1
- Copper alloy, lower mount (LM) G 1/4 B (male), 14 1
- DIN 11864 1
- DN 100__DN 25__DN 40__DN 50__DN 80 1
- Flange 17
- Flange__G ¼__G ¼ A__G ½ A__¼ NPT female__½ NPT 1
- Flange__G…›__G…œ 1
- Flange__Screwed 1
- Flanged 74
- G 1/4 (female)__G 1/4 (male) 1
- G 1 1
- G 1„8__G ¼ 2
- G 1„8__G ¼__M10 x 1__R 1/8__¼ NPT__…› NPT 2
- G 1¼ 1
- G 1¼ male thread 2
- G 1__G 1„8 1
- G1__G2__G¼__G½__G¾ 1
- G 1__G 2__G ¼__G ½__G…œ 1
- G1__G¼__G½__G¾ 2
- G 1__M33 x 2 1
- G1 B__G½ B__M20 x 1.5__Push-in/weld-in__½ NPT 1
- G1 female__G¾ B__M20 x 1.5 male 1
- G1-ISO 228 male 1
- G 1 male thread 1
- G1 male thread 2
- G2 2
- G¼ 4
- G ¼...G 1 2
- G¼ / H16 UNF 1
- G¼__G¼ A__G½ A__M20 x 1.5__¼ NPT female__½ NPT 1
- G ¼__G¾ 1
- G¼__G…› 1
- G ¼__SW 14 1
- G¼__SW 14 1
- G¼ A DIN 3852-E__¼ NPT 1
- G¼ A DIN 3852-E__sealing FKM/FPM 1
- G¼ B (male)__G½ B (male)__SW14__SW22 1
- G ¼ B (male)__Stainless steel 316L 1
- G ¼ B (male)__SW 14 1
- G¼ B (NS63)__G½ B (NS80, 100) 1
- G ¼ B__G …› B__¼ NPT__…› NPT 1
- G ¼ B female__G ½ B male__½ NPT male 1
- G ¼ female__G ½ female 1
- G ½ 1
- G½ 4
- G ½...G 2 2
- G ½__G¼ 1
- G ½__G¼__M20 x 1.5__½ NPT 1
- G ½__G¼__SW 14__SW 17__SW 22 1
- G ½__G¾ 1
- G½__G¾__M20 x 1.5__M27 x 2 4
- G ½__G¾__M24x2 1
- G½__G…œ__M20 x 1.5 2
- G ½__Lower mount__SW22 1
- G ½__Lower mount__SW 27 1
- G ½__SW 22 1
- G ½ B 2
- G ½ B (lower mount) 1
- G½ B (male)__Stainless steel 316L__SW 22 1
- G ½ B__¼ NPT__½ NPT 1
- G ½ B__½ NPT__½ NPT female 1
- G½ B__G¾ B male 1
- G ½ B__M20 x 1.5__½ NPT 1
- G ½ B female__G ½ B male__½ NPT male 1
- G ½ B male__SW 22 1
- G ½ B thread 1
- G½-ISO 228 male 1
- G½-ISO 228 male__G¾-ISO 228 1
- G½ male 1
- G¾ 5
- G…œ 1
- G …œ...G 1 1
- JIS flange 4
- Lower mount__¼ NPT female 1
- NS 40: G 1/8 B (male) NS 50, 63: G 1/4 B (male), 1
- Pipe adapter 1
- Rp 1/2__Rp 3/4 1
- Rp - female thread cylindrical (BSPT) 1
- Socket Weld 3
- Stainless steel 1
- Surface mounting 1
- Threaded 15
- UExSC 1
- UExUE 1
- Union End Sil Braze 9
- Union nut 1
- Via subplate with lateral female thread connection 2
Material Spec
Temperature Range
2-wire - ¼ NPT female
2 items

TR34 Miniature Resistance Thermometer
4337
The WIKA TR34 miniature resistance thermometer is used as universal thermometers for the measurement of liquid and gaseous media in the range -50 … +250 °C (-58 … +482 °F). The instruments are intrinsically safe and suitable for use in hazardous areas. The WIKA TR34 can be used for pressures up to 140 bar with 3 mm sensor diameters and up to 270 bar with 6 mm sensor diameters, depending on the instrument version. All electrical components are protected against humidity (IP67 or IP69K) and designed to withstand vibration (20 g, depending on instrument version). The resistance thermometer is available with direct sensor output or integrated transmitter, which can be configured individually via the PC configuration software WIKAsoft-TT. Measuring range, damping, fault signal per NAMUR NE43 and TAG no. can be adjusted. Insertion length, process connection, sensor and connection method can each be selected for the respective application within the order information. The WIKA TR34 resistance thermometer consists of a thermowell with a fixed process connection and is screwed directly into the process. The electrical connection is made via an M12 x 1 circular connector. An adapter for electrical connection with angular connector per DIN EN 175301-803 is optionally available (industrial property rights registered under No. 001370985).
- USD

PCS Compact Pressure Switch
7011
The high-quality WIKA PCS mechanical pressure switches have been developed especially for safety-critical applications with limited space. The high quality of the products and manufacturing following ISO 9001 ensure reliable monitoring of your plant. All wetted parts are from stainless steel as a standard. The switch enclosure is available in aluminium alloy or stainless steel. To adjust the setpoint, simply open the access cover plate. This access can be sealed as an option. The access to the terminal block for the electrical connection is protected by a screw-on lid, which is secured with a screw-type lock against unauthorised intervention. The pressure switches are fitted with one micro switch, which enables the switching of an electrical load of up to AC 250 V, 15 A directly. For lower switching power ratings, such as for PLS applications, argon gas-filled micro switches with gold-plated contacts can be selected as an option. For two separate circuits, the switches are also available in the version DPDT (double pole double throw). By using a diaphragm with antagonist spring as a sensor element, the model PCS pressure switch is extremely robust and guarantees optimal operating characteristics. For high setting ranges, a piston replaces or completes the diaphragm as a measuring element. The piston sensor element is designed for the specific requirements of liquid media.
- USD
1 - 2 of 2
1