close
Filter By
Company
Accuracy
Ambient Temperature
- 0...50°C 3
- 0...55°C 1
- 0...60°C 1
- 0...70°C 3
- 0...85°C 1
- 0...100°C 2
- 0...125°C 1
- 0...200°C 1
- 10...40°C 1
- -10...60°C 1
- -10...70°C 5
- -20°60°C 15
- -20...50°C 2
- -20...60°C 25
- -20...70°C 4
- -20...80°C 5
- -25...70°C 4
- -25...80°C 3
- -25...85°C 4
- -25...100°C 1
- -30...70°C 1
- -30...80°C 1
- -40...60°C 13
- -40...65°C 3
- -40...70°C 4
- -40...80°C 4
- -40...85°C 3
- -40...100°C 5
- -40...125°C 1
- -50...65°C 1
- -50...70°C 2
- -70...60°C 1
Connection Type
Flow Rate (l/min)
Material Spec
Medium Temperature
Pressure Range
0...70°C - -30...80°C
4 items

VTY 20 Turbine Flow Sensor
2808
The SIKA VTY 20 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. Turbine flow sensors of the series VTY stainless steel were specially developed for the use in industrial applications. The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials – sapphire and hard metal – also guarantee an exceptionally long endurance.
- USD

SIPART PS2 Valve Positioner
3734
The SIEMENS SIPART PS2 is a widely used positioner for linear and part-turn actuators in an extremely diverse range of process industries. The proven all-round talent provides comprehensive functions “ including intelligent diagnostics “ and can optionally communicate using HART 7, PROFIBUS PA 3.02 or Foundation Fieldbus ITK 6.0. A product that has been tried and tested so many times is always the right choice. The Siemens SIPART PS2 valve positioner is optionally available with Makrolon, aluminium, stainless or flameproof steel enclosure. The positioner is well-equipped for all ambient conditions. Available as standard with IP66 or NEMA 4x protection, it defies even challenging application environments. In dialogue with host systems, the vale positioner demonstrates its communicative side. It can be integrated into the most diverse communication landscapes using the PROFIBUS PA, Foundation Fieldbus or HART protocols. Furthermore, SIMATIC PDM can be applied with HART and PROFIBUS PA to clearly display and document saved trend values, histograms, and commissioning and operating data. The SIPART PS2 is equipped as standard with comprehensive diagnostics functions. To provide a warning of costly failures during operation, the positioner permanently checks the actuator and valve. The SIPART PS2 valve positionercommunicates ongoing events in real-time following NE107. Additionally, the SIPART PS2 provides diagnostics functions such as the œValve Performance Test (VPT). Using this test, the state of a valve can be assessed during a planned plant standstill. The diagnostics package of our positioner is rounded off by the œFull Stroke Test (FST), Step Response Test (SRT), and œMultistep Response Test (MSRT). The diagnostics cockpit allows users to obtain a clear introduction and quickly assess the state of a valve. With a regular œPartial Stroke Test (PST), the SIPART PS2 ensures that ESD (Emergency Shut Down) valves and other open/close valves remain free to move in emergencies. The positioner can also test the attached solenoid valve. The partial stroke test can be used for control valves to recognize maintenance requirements at an early stage during the ongoing process. Fail in place, and our multi-talent also provides fail-safe functions. The fail in place function causes the valve to remain in the last position should the power supply fail. Alternatively, the fail-safe function makes sure that the valve moves to the safety position. This function is even suitable for use in SIL2 measuring circuits. Siemens all-rounder can do even more: together with the SIPART PS2 booster; it allows fast control of large actuators with a Cv value of 2.0. Due to direct mounting on the positioner, the manual piping requirements are reduced to a minimum. Our positioner's numerous functions have made it what it is today: a multi-talent that can optimally handle a wide spectrum of specific challenges.
- USD

VTY 15 Turbine Flow Sensor
7792
The SIKA VTY 15 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. The VTY 15 turbine flow sensor is specially developed for installation in electrical heat interface units (HIU). The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials “ sapphire and hard metal “ also guarantee an exceptionally long endurance.
- USD

VTY 10 Turbine Flow Sensor
7793
The SIKA VTY 10 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. Turbine flow sensors of the series VTY 10 is also available in a plastic version. The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials “ sapphire and hard metal “ also guarantee an exceptionally long endurance.
- USD
1 - 4 of 4
1