close
Filter By
Company
Ambient Temperature
- 0...50°C 3
- 0...55°C 1
- 0...60°C 1
- 0...70°C 3
- 0...85°C 1
- 0...100°C 2
- 0...125°C 1
- 0...200°C 1
- 10...40°C 1
- -10...60°C 1
- -10...70°C 5
- -20°60°C 15
- -20...50°C 2
- -20...60°C 25
- -20...70°C 4
- -20...80°C 5
- -25...70°C 4
- -25...80°C 3
- -25...85°C 4
- -25...100°C 1
- -30...70°C 1
- -30...80°C 1
- -40...60°C 13
- -40...65°C 3
- -40...70°C 4
- -40...80°C 4
- -40...85°C 3
- -40...100°C 5
- -40...125°C 1
- -50...65°C 1
- -50...70°C 2
- -70...60°C 1
Connection Type
Medium Temperature
Nominal Size
Size
0...50°C - 0...100°C
5 items

ER2000 Electronic Controller
2183
The Clorius ER 2000 electronic controller is used for constant temperature control. It is suitable for all heating and cooling control systems. The controller is primarily intended for marine installations and other industrial applications – such as cooling water and lubricating oil installations, flow temperature control etc. Design The ER 2000 controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has three keys – two for scrolling or changing values and an enter key. Two digital displays show the process variable and the setpoint. 3 LEDs indicate actuator opens, actuator closes and alarm. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP It can operate either as a three-position or as a two-position controller or analogue (4-20 mA) controller and has an adjustable proportional band, integral action time and derivative action time. Function The temperature input comes via a Pt 100 sensor with a single sensing element. The measured value of the controlled variable is compared with the setpoint value and adjusted via a PI or a PID control structure. The ER 2000 can act as either a heating controller, the actuator closes at rising temperature, or as a cooling controller, the actuator opens at rising temperature. The ER 2000 permits direct reading of the actual temperature value (PV), and it is secured from failure in the measuring circuit, i.e. the controller can be set to give either a closing, an opening, or remain in current position command in case of sensor short circuit or sensor break. The error message Err appears in the LED display PV.
- USD

PGS23.1x0 Bourdon Tube Pressure Gauge
4219
Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the WIKA PGS23.100 and PGS23.160 switchGAUGE finds its use. Switch contacts (electrical switch contacts) make or break an electric control circuit dependent upon the pointer position of the indicating measuring instrument. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window. Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.
- USD

PGT63HP.100 / PGT63HP.160 Pressure Gauge
7204
Wherever very low pressures have to be indicated locally and, at the same time, a signal transmission to the central control or remote centre is desired, the WIKA PGT63HP.100 / PGT63HP.160 pressure gauge intelliGAUGE® (patent, property right: e.g. DE 202007019025) can be used. The robust capsule measuring system has an overload safety of up to 50 times the full-scale value. An electronic angle encoder, proven in safety-critical automotive applications, determines the position of the pointer shaft “ it is a non-contact sensor and therefore completely free from wear and friction. From this, the electrical output signal proportional to the pressure, e.g. 4 … 20 mA, is produced. The measuring span (electrical output signal) is adjusted automatically along with the mechanical display, i.e. the scale over the full display range corresponds to 4 … 20 mA. The electrical zero point can also be set manually. The electronic WIKA sensor, integrated into the high-quality capsule pressure gauge, combines the advantages of electrical signal transmission with a local mechanical display that remains readable during a power failure. An additional measuring point for mechanical pressure display can thus be saved.
- USD

ER2000-P Electric Controller
9171
The Clorius ER 2000-P controller is used for constant pressure control. It is suitable for all heating and cooling control systems. The controller is primarily intended for marine installations and other industrial applications. Design The ER 2000-P controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has three keys – two for scrolling or changing values and an enter key. Two digital displays show the process variable and the setpoint. 3 LEDs indicate actuator opens, actuator closes and alarm. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP It can operate either as a three-position or as a two-position controller or analogue controller (4-20 mA) and has an adjustable proportional band, integral action time and derivative action time. Function The pressure input comes via a 4-20 mA signal. The measured value of the controlled variable is compared with the setpoint value and adjusted via a PI or a PID control structure. The ER 2000-P permits direct reading of the actual temperature value (PV) and it is secured from failure in the measuring circuit, i.e. the controller can be set to give either a closing, an opening or remain in current position command in case of sensor short circuit or sensor break. The error message Err appears in the LED display PV.
- USD

ER3000 Electric Controller
9175
The Clorius ER 3000e electric controller is used for constant temperature control. It is specially designed for large engine jacket cooling water systems where conventional single loop controllers cannot maintain a constant and precise temperature. The ER3000 controller operates with TWO sensor inputs. One Pt 100 sensor is placed at the outlet from the engine and one Pt 100 sensor with a built-in 4-20 mA transmitter is placed at the inlet to the engine. The measured values of the controlled variables are compared with the setpoint value and adjusted via a PI or a PID control structure. Design The ER 3000 controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has four keys – two for scrolling or changing values, an enter key and a key for choosing manual or automatic control. Two digital displays show the process variable and the setpoint. 7 LEDs indicate alarm, the actuator opens, actuator closes, slave control, setpoint raising/lowering and manual mode. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP The 3 alarm settings include an alarm in case of a sensor fault. It can operate either as a three-position or as a two-position controller and has adjustable proportional band, integral action time and derivative action time.
- USD
1 - 5 of 5
1