Filter Sort
close
1 - 7 of 7
ER2000 Electronic Controller

ER2000 Electronic Controller

2183

The Clorius ER 2000 electronic controller is used for constant temperature control. It is suitable for all heating and cooling control systems. The controller is primarily intended for marine installations and other industrial applications – such as cooling water and lubricating oil installations, flow temperature control etc. Design The ER 2000 controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has three keys – two for scrolling or changing values and an enter key. Two digital displays show the process variable and the setpoint. 3 LEDs indicate actuator opens, actuator closes and alarm. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP It can operate either as a three-position or as a two-position controller or analogue (4-20 mA) controller and has an adjustable proportional band, integral action time and derivative action time. Function The temperature input comes via a Pt 100 sensor with a single sensing element. The measured value of the controlled variable is compared with the setpoint value and adjusted via a PI or a PID control structure. The ER 2000 can act as either a heating controller, the actuator closes at rising temperature, or as a cooling controller, the actuator opens at rising temperature. The ER 2000 permits direct reading of the actual temperature value (PV), and it is secured from failure in the measuring circuit, i.e. the controller can be set to give either a closing, an opening, or remain in current position command in case of sensor short circuit or sensor break. The error message Err appears in the LED display PV.
View Details
712.15.160 / 732.15.160 Differential Pressure Gauge

712.15.160 / 732.15.160 Differential Pressure Gauge

2510

The WIKA 712.15.160 and 732.15.160 Differential pressure gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks. With only six different measuring cells all usual tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270-degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and easily. An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument. The level display can be supplied with an optional, integrated 4 ¦ 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure, can be retrofitted on-site. Versions with transmitters can be expanded with the Remote data transfer module intelliMETRY. The intelliMETRY sends measured data to an online data centre using GSM technology. The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.
View Details
712.15.100 & 732.15.100 Differential Pressure Gauge

712.15.100 & 732.15.100 Differential Pressure Gauge

3367

The WIKA 712.15.100 and 732.15.100 differential pressure gauge high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks. With 11 different measuring cells, all common tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270-degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and efficiently. An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and operating pressure possible in the one instrument. The level display can be supplied with an optional, integrated 4 ¦ 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure, can be retrofitted on-site. The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.
View Details
IPT-20 / 21 Process Transmitter

IPT-20 / 21 Process Transmitter

7101

With its 4 … 20 mA, 4 … 20 mA HART®, PROFIBUS® PA or FOUNDATION Fieldbus„¢ output signals, combined with either intrinsic safety or flameproof enclosure ignition protection type (in accordance with ATEX and IECEx), the WIKA IPT-20 / 21 is ideally suited to applications with the highest demands on the measurement technology. Versatile in application As a result of the available measuring ranges of 0 … 0.1 bar to 0 … 4,000 bar (0 … 0.15 to 0 … 60,000 psi) and a freely selectable turndown, the instrument can be used in almost any application. A large number of process connections and the extensive possibilities offered by the metallic measuring cell enable use in all industries. There are seven different case variants available, and thus it is possible to select a variant suited to every operating environment. The case itself can be rotated through 330° and is available in plastic, aluminium and stainless steel. An electropolished stainless steel case (316L) is available to meet the high demands of the food and pharmaceutical industries. Easy configuration and operation Service and configuration at the instrument are carried out using the optional display and operating module, which can be fitted in four positions. The operating menu has a simple and self-explanatory structure and has nine selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware„¢ free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into corresponding process control systems.
View Details
CPT-20 / 21 Process Transmitter

CPT-20 / 21 Process Transmitter

7110

With its 4 … 20 mA, 4 … 20 mA HART®, PROFIBUS® PA or FOUNDATION Fieldbus„¢ output signals, combined with either intrinsic safety or flameproof enclosure ignition protection type (following ATEX and IECEx), the WIKA CPT-20 / 21 process transmitter is ideally suited to applications with the highest demands on measurement technology. Robust and highly accurate The capacitive ceramic measuring cell delivers especially accurate measured values, particularly with small measuring ranges. As a result of the special sealing concept, operation in almost all industries and applications is possible without difficulties. There are seven different case variants available, and thus, it is possible to select a variant suited to every operating environment. The case itself can be rotated through 330° and is available in plastic, aluminium and stainless steel. An electropolished stainless steel case (316L) is available to meet the high demands of the food and pharmaceutical industries. Easy configuration and operation Service and configuration at the instrument are carried out using the optional display and operating module, which can be fitted in four positions. The operating menu has a simple and self-explanatory structure and has thirteen selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware„¢ free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into corresponding process control systems.
View Details
ER2000-P Electric Controller

ER2000-P Electric Controller

9171

The Clorius ER 2000-P controller is used for constant pressure control. It is suitable for all heating and cooling control systems. The controller is primarily intended for marine installations and other industrial applications. Design The ER 2000-P controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has three keys – two for scrolling or changing values and an enter key. Two digital displays show the process variable and the setpoint. 3 LEDs indicate actuator opens, actuator closes and alarm. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP It can operate either as a three-position or as a two-position controller or analogue controller (4-20 mA) and has an adjustable proportional band, integral action time and derivative action time. Function The pressure input comes via a 4-20 mA signal. The measured value of the controlled variable is compared with the setpoint value and adjusted via a PI or a PID control structure. The ER 2000-P permits direct reading of the actual temperature value (PV) and it is secured from failure in the measuring circuit, i.e. the controller can be set to give either a closing, an opening or remain in current position command in case of sensor short circuit or sensor break. The error message Err appears in the LED display PV.
View Details
ER3000 Electric Controller

ER3000 Electric Controller

9175

The Clorius ER 3000e electric controller is used for constant temperature control. It is specially designed for large engine jacket cooling water systems where conventional single loop controllers cannot maintain a constant and precise temperature. The ER3000 controller operates with TWO sensor inputs. One Pt 100 sensor is placed at the outlet from the engine and one Pt 100 sensor with a built-in 4-20 mA transmitter is placed at the inlet to the engine. The measured values of the controlled variables are compared with the setpoint value and adjusted via a PI or a PID control structure. Design The ER 3000 controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has four keys – two for scrolling or changing values, an enter key and a key for choosing manual or automatic control. Two digital displays show the process variable and the setpoint. 7 LEDs indicate alarm, the actuator opens, actuator closes, slave control, setpoint raising/lowering and manual mode. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP The 3 alarm settings include an alarm in case of a sensor fault. It can operate either as a three-position or as a two-position controller and has adjustable proportional band, integral action time and derivative action time.
View Details
1 - 7 of 7