712.15.160 / 732.15.160 Differential Pressure Gauge
2510
The WIKA 712.15.160 and 732.15.160 Differential pressure gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks. With only six different measuring cells all usual tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270-degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and easily. An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument. The level display can be supplied with an optional, integrated 4 ¦ 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure, can be retrofitted on-site. Versions with transmitters can be expanded with the Remote data transfer module intelliMETRY. The intelliMETRY sends measured data to an online data centre using GSM technology. The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.
- USD

PG23LT Bourdon Tube Pressure Gauge
2557
The WIKA PG23LT high-quality pressure gauge has been designed specifically for extremely low ambient temperatures down to -70 °C (-94 °F). The stainless steel Bourdon tube pressure gauge finds applications in particularly cold regions such as Russia, Canada, Scandinavia or China. The WIKA model PG23LT is used primarily in the oil and gas industries and in the petrochemical industry. The typical measuring points are located on pipelines or in pumping stations for oil and gas transportation. As a result of the special low-temperature design of the instrument, the use of special seals and the case filling, the WIKA model PG23LT is suitable for outdoor applications down to an ambient temperature of -70 °C (-94 °F). The same instrument design fulfils the requirements for both IP 66 and IP 67 ingress protection for pressure ranges greater than 0 ¦ 16 bar. Tested and qualified in WIKA's own laboratory, the suitability of the instrument for ambient temperatures down to -70 °C (-94 °F) is confirmed as standard with each order by a 2.2 test report.
- USD

712.15.100 & 732.15.100 Differential Pressure Gauge
3367
The WIKA 712.15.100 and 732.15.100 differential pressure gauge high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks. With 11 different measuring cells, all common tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270-degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and efficiently. An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and operating pressure possible in the one instrument. The level display can be supplied with an optional, integrated 4 ¦ 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure, can be retrofitted on-site. The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.
- USD

IPT-20 / 21 Process Transmitter
7101
With its 4 … 20 mA, 4 … 20 mA HART®, PROFIBUS® PA or FOUNDATION Fieldbus„¢ output signals, combined with either intrinsic safety or flameproof enclosure ignition protection type (in accordance with ATEX and IECEx), the WIKA IPT-20 / 21 is ideally suited to applications with the highest demands on the measurement technology. Versatile in application As a result of the available measuring ranges of 0 … 0.1 bar to 0 … 4,000 bar (0 … 0.15 to 0 … 60,000 psi) and a freely selectable turndown, the instrument can be used in almost any application. A large number of process connections and the extensive possibilities offered by the metallic measuring cell enable use in all industries. There are seven different case variants available, and thus it is possible to select a variant suited to every operating environment. The case itself can be rotated through 330° and is available in plastic, aluminium and stainless steel. An electropolished stainless steel case (316L) is available to meet the high demands of the food and pharmaceutical industries. Easy configuration and operation Service and configuration at the instrument are carried out using the optional display and operating module, which can be fitted in four positions. The operating menu has a simple and self-explanatory structure and has nine selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware„¢ free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into corresponding process control systems.
- USD

CPT-20 / 21 Process Transmitter
7110
With its 4 … 20 mA, 4 … 20 mA HART®, PROFIBUS® PA or FOUNDATION Fieldbus„¢ output signals, combined with either intrinsic safety or flameproof enclosure ignition protection type (following ATEX and IECEx), the WIKA CPT-20 / 21 process transmitter is ideally suited to applications with the highest demands on measurement technology. Robust and highly accurate The capacitive ceramic measuring cell delivers especially accurate measured values, particularly with small measuring ranges. As a result of the special sealing concept, operation in almost all industries and applications is possible without difficulties. There are seven different case variants available, and thus, it is possible to select a variant suited to every operating environment. The case itself can be rotated through 330° and is available in plastic, aluminium and stainless steel. An electropolished stainless steel case (316L) is available to meet the high demands of the food and pharmaceutical industries. Easy configuration and operation Service and configuration at the instrument are carried out using the optional display and operating module, which can be fitted in four positions. The operating menu has a simple and self-explanatory structure and has thirteen selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware„¢ free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into corresponding process control systems.
- USD