Filter Sort
close
1 - 7 of 7
A2G-52 Dual Differential Pressure Transmitter

A2G-52 Dual Differential Pressure Transmitter

2773

The WIKA A2G-52 dual differential pressure sensor combines two differential pressure sensors in one instrument so that pressure can be measured from two different control points. The WIKA A2G-52 has a Modbus® interface and an input interface. By using the input interface, up to two passive temperature sensors or an analogue 0 … 10 V signal can be connected directly to the measuring instrument. Thus, the use of cost-intensive active temperature transmitters can be dispensed with and the costs for material and mounting can be reduced.
View Details
PK 944/947 Pressostat

PK 944/947 Pressostat

3994

The Trafag PK 944/947 pressure switches provide high vibration resistance and switch point precision in combination with an extremely robust and durable design. This results in Trafag PK 944/947 pressure switches that can be operated for decades without requiring maintenance, even under harsh conditions. Various designs with bellows, membrane and piston sensors cover a wide variety of pressure ranges, media and load profiles for many different applications.
View Details
BCP Pressure Switch

BCP Pressure Switch

5285

The Danfoss BCP pressure switch is a series of dedicated pressure switches for the safety and pressure monitoring of steam and hot water boilers. The Danfoss BCP incorporates a single-pole changeover microswitch where the contact position depends on the pressure in the connection port and the range set value. For installations, in which operation is particularly critical for safety reason, the use of the fail-safe control is recommended.
View Details
KP Pressure Switch

KP Pressure Switch

5288

The Danfoss KP pressure switches are used for regulating, monitoring and alarm systems in the industry. The KP pressure switches provide automatic limit protection or manual reset limit protection for pressure systems. The KP switches can be used with steam, air, gaseous and liquid media. The pressure switches are fitted with a single-pole changeover switch (SPDT). The position of the switch depends on the setting of the pressure switch and the pressure in the connector. Available types: KP 34 pressure switch KP 35 pressure switch KP 36 pressure switch KP 37 pressure switch KP 44 pressure switch
View Details
CS Pressure Switch

CS Pressure Switch

5294

The Danfoss CS pressure switch series has a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the range setting and adjustable differential. The Danfoss CS pressure switches are fitted with a manual switch that will lock the contact system in the open position independently of the pressure in the system. Pressure switches with relief valve are used in compressed air systems where pressure relief on the compressor piston before the start is required. The CS is suited for an automatic start and stop of air compressors and water boosters.
View Details
KP44 Dual Pressure Switch

KP44 Dual Pressure Switch

5300

The Danfoss KP44 pressure switch is used in refrigeration and air conditioning systems to give protection against excessively low suction pressure or too high discharge pressure. The Danfoss KP44 pressure switch is also used for starting and stopping refrigeration compressors and fans on air-cooled condensers. A KP pressure switch can be connected directly to a single-phase AC motor of up to approx. 2 kW or installed in the control circuit of DC motors and large AC motors. Danfoss KP pressure switches are fitted with a single-pole double-throw (SPDT) switch. The position of the switch is determined by the pressure switch setting and the pressure at the connector. KP pressure switches are available in IP30, IP44 and IP55 enclosures
View Details
KP Thermostat

KP Thermostat

9384

The Danfoss KP Thermostats are single-pole, double-throw (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kW or installed in the control circuit of DC motors and large AC motors. The Danfoss KP Thermostats are used for regulation but can also be seen in safety monitoring systems. The KP thermostats are available with vapour charge or with adsorption charge. With a vapour charge, the differential is minimal. The KP Thermostats with adsorption charge Available types: KP 61 Thermostat KP 62 Thermostat KP 63 Thermostat KP 68 Thermostat KP 69 Thermostat KP 71 Thermostat KP 73 Thermostat KP 75 Thermostat KP 77 Thermostat KP 79 Thermostat KP 81 Thermostat KP 98 Thermostat
View Details
1 - 7 of 7