Accuracy
- 0.01% FS 4
- 0.1%__±0.1 mm 7
- 0.1 mm 2
- 0.02% FS 2
- 0.2%__±1 mm/s 6
- 0.2%__±2.5 mm/s 1
- 0.2% FS 1
- 0.3% FS 1
- 0.3...0.1 1
- 0.04%__0.065% 1
- 0.4 %__± 1 mm/s 1
- 0.5% FS 2
- 0.6%__1% 1
- 0.10% 1
- 0.15% 1
- 0.025%__0.1% 1
- 0.25% 4
- 0.30% 1
- 0.50% 22
- 2.3% FS 1
- 2.5 1
- 3...24 mm 2
- 4% 1
- ±0.2 l/min 1
- ± 0.3%__± 1.5% 2
- ±0.4 l/min 3
- ± 0.5% FS 3
- ± 0.5% FS__± 1% FS 1
- ±0.5% of flow rate 1
- ±0.10 % 1
- ±0.10 %__±0.20 % 1
- ±1% 3
- ±1 % of range, ±3 % of reading (from 15 l/min) 1
- ±1.5mm 1
- ±1.25 mm 1
- ± 1__± 3% 1
- ± 2%__± 2°C 4
- ± 2°C 1
- ±2mm 4
- ±3°C 1
- ± 3 mm 2
- ± 5% 5
- EN1434 Class 3, typical ±(0.5 + 3K/ΔΘ) [%] 1
Approvals
Medium Temperature
Pressure Range
0.3...0.1, ± 0.5% FS__± 1% FS - 0.025%__0.1%
3 items

CPG 1500 Digital Pressure Gauge
2776
The WIKA CPG1500 precision digital pressure gauge takes the concept of an analogue gauge and raises it to a level only matched by digital calibrators. The accuracy of digital measurement technology and the simplicity of an analogue gauge are combined to create the digital pressure gauge CPG1500, which in terms of performance, ease-of-use, and instrument features, is unmatched in the pressure measurement market. The WIKA CPG1500 offers an accuracy of 0.1 % FS (optional 0.05 % FS or 0.025 % FS) and is temperature-compensated in the range of -10 ¦ +50 °C (14 … 122 °F). Readings can be displayed in one of 26 pressure and 5 level units or also in customer-specific units, so that intricate conversion is avoided. The measuring rate can be user-defined to match the type of measurement required. Standard applications usually use three measured values per second. If required, this rate can also be set to 50 measured values per second. Via an energy-saving function, the CPG1500 switches automatically into œsleep mode, in this mode, the battery life can be increased up to 2,500 hours. Through the new and innovative menu navigation, simple operation is ensured. The clear display, with integral bar graph display and large text area, assists with the effective analysis of the widest variety of measuring points. With the MIN/MAX function, the highest and lowest pressures can be accessed immediately and saved automatically.
- USD

MBS 4201/4251/4701/4751 Pressure Transmitter
5145
The intrinsically safe Danfoss MBS 4201, MBS 4251, MBS 4701 and MBS 4751 pressure transmitter program is designed for use in hazardous environments. It offers a reliable pressure measurement, even in harsh applications with severe medium influences like cavitation, liquid hammer or pressure peaks. The Danfoss MBS 4201 and MBS 4251 pressure transmitters are Ex ia IIC T6…T4 explosion protected according to the ATEX directive 94/9/EC. In contrast, the Danfoss MBS 4701 and MBS 4751 pressure transmitters are Ex ia IIC T4 explosion protected. Both series come with 4“20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0…600 bar, zero point and span adjustment, plug connection and a wide range of pressure connections. Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
- USD

CPC2000 Portable Low-Pressure Controller
8212
The WIKA CPC2000 portable low pressure controller is used in the areas of heating, ventilation, air conditioning, filtration, clean room, and medical technology as a calibrator or as highly-accurate measurement equipment and/or precise pressure transducer. The WIKA CPC2000 low-pressure controller is a mains or battery-operated pressure controller with internal, automatic pressure generation and pressure reference. The pressure generation is achieved using an integrated, electric pump, which makes a positive and/or negative pressure available on both the tube connections. As soon as the instrument is switched on, a zero-point adjustment is automatically carried out, so that a zero-point drift is eliminated. The subsequent preparation of a calibration requires only a few settings. First, using the MENU button, select one of the stored pressure units and the variable pressure change step in the range of 0 … 50 %. Then, once the full scale has been entered in Control Mode, the pressure can be easily increased or decreased by the defined level using the navigation buttons. To check whether the calibration assembly or the test item has a leak, the LEAK button can be used. With this, the pressure is locked into the test assembly and any pressure drop there might be, as well as the the time this takes, is measured and displayed. The CPC2000 has an RS-232 and USB interface, enabling communication and data exchange with a PC. WIKA-Cal calibration software is available for the CPC2000. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. The accuracy of the instrument is certified by a factory calibration certificate.
- USD
1 - 3 of 3