close
Categories
Filter By
Company
Accuracy
- 0.01% FS 4
- 0.1%__±0.1 mm 7
- 0.1 mm 2
- 0.02% FS 2
- 0.2%__±1 mm/s 6
- 0.2%__±2.5 mm/s 1
- 0.2% FS 1
- 0.3% FS 1
- 0.3...0.1 1
- 0.04%__0.065% 1
- 0.4 %__± 1 mm/s 1
- 0.5% FS 2
- 0.6%__1% 1
- 0.10% 1
- 0.15% 1
- 0.025%__0.1% 1
- 0.25% 4
- 0.30% 1
- 0.50% 22
- 2.3% FS 1
- 2.5 1
- 3...24 mm 2
- 4% 1
- ±0.2 l/min 1
- ± 0.3%__± 1.5% 2
- ±0.4 l/min 3
- ± 0.5% FS 3
- ± 0.5% FS__± 1% FS 1
- ±0.5% of flow rate 1
- ±0.10 % 1
- ±0.10 %__±0.20 % 1
- ±1% 3
- ±1 % of range, ±3 % of reading (from 15 l/min) 1
- ±1.5mm 1
- ±1.25 mm 1
- ± 1__± 3% 1
- ± 2%__± 2°C 4
- ± 2°C 1
- ±2mm 4
- ±3°C 1
- ± 3 mm 2
- ± 5% 5
- EN1434 Class 3, typical ±(0.5 + 3K/ΔΘ) [%] 1
Ambient Temperature
Approvals
Connection Type
Flow Rate (l/min)
Measuring range
Medium Temperature
Nominal Diameter
Nominal Size
0.1 mm, ± 5% - ± 3 mm
9 items

Underwater Thickness Gauge
1162
The Cygnus Underwater is the original diver held subsea multiple echo ultrasonic thickness gauge. It was designed for use by divers undertaking subsea maintenance and surveys 3 decades ago¦ and today it is still the industry standard. The unit is depth rated to 300 meters (985 ft) and it provides an accurate metal thickness measurement through coatings up to 20 mm (0.787 in) thick using Deep Coat mode (upon request). The bright LED display ensures easy viewing even in poor visibility conditions. The Cygnus Underwater thickness gauge is supplied ready to use as a complete kit with 2 rechargeable batteries in a protective carry case. Features: RINA approved (Certificate No. 2009DGPO787) Auto Probe Recognition (APR) Deep-Coat mode for measuring through coatings up to 20 mm (0.787 in) thick (upon request) Easy calibration using convenient buttons Rugged, durable, shock-proof construction Stable calibration “ linear accuracy “ no zero adjustment Large bright LED display for poor visibility Pressure rated to 300 m (985 ft) depth Heavy-duty sealed unit with double ˜O™ ring protection Self-verification of measurements to ensure accuracy Echo strength indicator to aid measurement All probes are protected by a membrane to prevent damage Various probe options Two rechargeable battery packs with charger Fixed head probe option for single-handed use
- USD

Mini ROV Mountable
1167
The Cygnus Mini ROV Mountable thickness gauge has been specially designed to be mounted onto small observation ROVs with or without a manipulator facility. Built-in conjunction with VideoRay, this mountable subsea thickness gauge will allow the operator to carry out an ultrasonic thickness measurement in areas that have previously been unfeasible using larger ROVs or divers. The multiple echo thickness gauge measures metal thickness and corrosion without removing protective coatings. Dedicated software displays the time, date and thickness readings on the surface which can all be stored or logged. Alternatively, an optional Topside Repeater (TSR) is available which has the facility to display the thickness measurements remotely and overlay them on to a video signal. This allows the measurements to be superimposed on the ROV camera™s monitor screen. The unit is pressure tested to 1,640 ft (500 m). Features: Designed specifically to mount onto small observation ROV™s. Supplied with *CygLink software to display and log thickness measurements from the ROV on a computer at the surface which can be saved to a file and printed out. CygLink has two data logging facilities: Quick Log for simple recording of thickness measurements and structured mode with four templates available “ Single Point, Multi Point, Grid Point and KeyPoint. Easy calibration at the surface via CygLink software or Top Side Repeater (TSR) unit. Optional dedicated probe holder to allow measurements on curved or flat surfaces. Only one twisted pair is required to transfer the data to the surface.
- USD

A2G-mini Differential Pressure Gauge
5075
The WIKA A2G-mini differential pressure gauge can be used for monitoring differential pressures of the filter units in small and medium-sized central air-handling units. Further application cases are in industrial air extraction units and dust extraction plants as well as in the cleanroom industry. Its compact design and flush panel mounting enable an optimal integration in the enclosure structures of ventilation equipment. The pure metal design “ with the case of stainless steel and the measuring system and movement from copper alloy “ ensures maximum hygiene. Due to its silicone-free materials, the instrument can also be used in the painting industry and its applications. The high IP68 ingress protection and the UV-stabilised window also enable operation in outdoor areas.
- USD

VTM 40 Turbine Flow Sensor
7803
The SIKA VTM 40 turbine flow sensor is made for flow measurement or dosing applications for liquids. Because of the very compact design, the extensive measuring range and the convincing precision of measurements, almost unlimited applications are possible. The sturdy bearing materials – sapphire and tungsten carbide – also guarantee an exceptionally long endurance. The liquid flowing into the SIKA VTM 40 turbine flow sensor is split into individual jets by the guiding blade. These jets hit the rotor evenly from different directions, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. The construction of the guiding blade and rotor enables to realize the very low start-up flow values.
- USD

VTH 40 Turbine Flow Sensor
7805
The SIKA VTH 40 turbine flow sensor is made for flow measurement or dosing applications for liquids. Because of the very compact design, the extensive measuring range and the convincing precision of measurements, almost unlimited applications are possible. The sturdy bearing materials – sapphire and tungsten carbide – also guarantee an exceptionally long endurance. The liquid flowing into the SIKA VTH 40 turbine flow sensor is split into individual jets by the guiding blade. These jets hit the rotor evenly from different directions, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. The construction of the guiding blade and rotor enables to realize the very low start-up flow values.
- USD

VTM 25 Turbine Flow Sensor
7807
The SIKA VTM 25 turbine flow sensor is made for flow measurement or dosing applications for liquids. Because of the very compact design, the extensive measuring range and the convincing precision of measurements, almost unlimited applications are possible. The sturdy bearing materials – sapphire and tungsten carbide – also guarantee an exceptionally long endurance. The liquid flowing into the SIKA VTM 25 turbine flow sensor is split into individual jets by the guiding blade. These jets hit the rotor evenly from different directions, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. The construction of the guiding blade and rotor enables to realize the very low start-up flow values.
- USD

VTH 25 Turbine Flow Sensor
7809
The SIKA VTH 25 turbine flow sensor is made for flow measurement or dosing applications for liquids. Because of the very compact design, the extensive measuring range and the convincing precision of measurements, almost unlimited applications are possible. The sturdy bearing materials – sapphire and tungsten carbide – also guarantee an exceptionally long endurance. The liquid flowing into the SIKA VTH 25 turbine flow sensor is split into individual jets by the guiding blade. These jets hit the rotor evenly from different directions, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. The construction of the guiding blade and rotor enables to realize the very low start-up flow values.
- USD

RLS-1000 Float Switch
8111
The WIKA RLS-1000 float switch is a robust, reliable and inexpensive float switch. The monitoring of levels, as well as dry-run protection and overflow protection, are cost-sensitive applications in the machine-building industry, therefore a float switch is a perfect solution for many plants. The RLS-1000 float switch offers reliable measurements for the level in vessels with water, oil, diesel or other liquids by means of a permanent magnet and frictionless reed contacts at max. 4 defined switch points and can be used in a medium temperature range from -30 to +150 °C (-22 to +302 °F). The WIKA RLS-1000 float switch is simple, easy to use and fast to integrate because it does not need to be calibrated or set during the installation. This greatly improves the ease of handling, especially in confined installation situations. Also, since its robust design makes it resistant to vibrations and shocks, maintenance costs are minimal.
- USD

RLS-2000 Float Switch
8114
The WIKA RLS-2000 float switch is a reliable and inexpensive float switch made of high-quality plastic. The WIKA RLS-2000 float switch is particularly suited for measuring the levels of aggressive and corrosive media, such as bases and acids. For cost-sensitive applications such as the monitoring of levels or overflow and dry-run protection, float switches are an ideal solution. The WIKA RLS-2000 float switch detects the level using a permanent magnet and frictionless reed contacts at up to 4 defined switch points, without contact and thus free from wear. Integration as a limit level switch is simple, convenient and fast, because no adaptation or calibration is required during installation. The robust design minimises service and maintenance costs.
- USD