close
Filter By
Company
Accuracy
- 0.01% FS 4
- 0.1%__±0.1 mm 7
- 0.1 mm 2
- 0.02% FS 2
- 0.2%__±1 mm/s 6
- 0.2%__±2.5 mm/s 1
- 0.2% FS 1
- 0.3% FS 1
- 0.3...0.1 1
- 0.04%__0.065% 1
- 0.4 %__± 1 mm/s 1
- 0.5% FS 2
- 0.6%__1% 1
- 0.10% 1
- 0.15% 1
- 0.025%__0.1% 1
- 0.25% 4
- 0.30% 1
- 0.50% 22
- 2.3% FS 1
- 2.5 1
- 3...24 mm 2
- 4% 1
- ±0.2 l/min 1
- ± 0.3%__± 1.5% 2
- ±0.4 l/min 3
- ± 0.5% FS 3
- ± 0.5% FS__± 1% FS 1
- ±0.5% of flow rate 1
- ±0.10 % 1
- ±0.10 %__±0.20 % 1
- ±1% 3
- ±1 % of range, ±3 % of reading (from 15 l/min) 1
- ±1.5mm 1
- ±1.25 mm 1
- ± 1__± 3% 1
- ± 2%__± 2°C 4
- ± 2°C 1
- ±2mm 4
- ±3°C 1
- ± 3 mm 2
- ± 5% 5
- EN1434 Class 3, typical ±(0.5 + 3K/ΔΘ) [%] 1
Ambient Temperature
Connection Type
Flow Rate (l/min)
Material Spec
Medium Temperature
Pressure Range
±1%, 0.3% FS - 2.3% FS
5 items

VTY 20 Turbine Flow Sensor
2808
The SIKA VTY 20 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. Turbine flow sensors of the series VTY stainless steel were specially developed for the use in industrial applications. The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials – sapphire and hard metal – also guarantee an exceptionally long endurance.
- USD

MBS 5100/5150 Pressure Transmitter
5154
The ship approved high accuracy Danfoss MBS 5100 and MBS 5150 block pressure transmitter is designed for use in almost all marine applications. The Danfoss MBS 5150 pressure transmitter with integrated pulse snubber is designed for use in marine applications with severe medium influences like cavitation, liquid hammer or pressure peaks and offers a reliable pressure measurement, even under harsh environmental conditions. The transmitters can be easily mounted directly on the MBV 5000 block test valve, or the threaded pressure connection can be used. The flexible pressure transmitter programme covers a 4 “ 20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0…1 to 0…400 bar with zero and span adjustment. Excellent vibration stability, robust construction, and a high degree of EMC / EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
- USD

EMP 2 Pressure Transmitter
5168
The Danfoss EMP 2 pressure transmitter is a high accuracy pressure transmitter designed to monitor and control marine and industrial applications. It offers a reliable pressure measurement, even under harsh environmental conditions. The flexible EMP 2 pressure transmitter programme covers absolute or gauge (relative) versions with zero and span adjustment with a 4 “ 20 mA output signal. It has all the necessary marine approvals. Special versions with integrated pulse-snubber available, designed for use in hydraulic applications with severe medium influences like cavitation, liquid hammer or pressure peaks. The Danfoss EMP 2 is made for use in zone 2 explosive atmospheres.
- USD

VTY 15 Turbine Flow Sensor
7792
The SIKA VTY 15 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. The VTY 15 turbine flow sensor is specially developed for installation in electrical heat interface units (HIU). The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials “ sapphire and hard metal “ also guarantee an exceptionally long endurance.
- USD

VTY 10 Turbine Flow Sensor
7793
The SIKA VTY 10 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. Turbine flow sensors of the series VTY 10 is also available in a plastic version. The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials “ sapphire and hard metal “ also guarantee an exceptionally long endurance.
- USD
1 - 5 of 5
1