close
Filter By
Company
Instrument Valves & Manifolds
38 items

Process Monoflanges
8430
AS-Schneider Process Monoflanges (A frequently used term is also Slimline Monoflange) are designed to replace the traditional primary isolation valve and are close-coupled to the process piping flange, for connecting process to instruments. The primary isolation valve needs to be of process design, therefore it's a valve with OSandY Bolted Bonnet. The secondary isolation valve and the bleed valve are provided with screwed bonnets. The combining of piping and instrument valves into a single unit has benefitted various markets. The Standard Pressure Instrument Connection is 1/2 NPT female, the Standard Process Connections are provided with Flange Connections acc. to ASME B 16.5. AS-Schneider is providing axial, radial or dual outlet types for either Horizontal or Vertical Flange Mounting. The Monoflanges are available as Block, Block and Bleed or Double Block and Bleed designs.
- USD

Instrument Monoflanges
8434
AS-Schneider Instrument Monoflanges are close-coupled to a pre-installed primary isolation valve to provide a compact instrument Double Block and Bleed Valve or are used when primary isolation valves with an OS and Y Bolted Bonnet are not required. The needle valves of the Instrument Monoflanges are provided with a screwed bonnet. The Standard Pressure Instrument Connection is 1/2 NPT female, the Standard Process Connections are provided by Flange Connections acc. to ASME B 16.5. AS-Schneider is providing axial, radial or dual outlet types for either Horizontal or Vertical Flange Mounting. The Monoflanges are available as Block, Block and Bleed or Double Block and Bleed designs.
- USD

VariAS-Blocks
8438
AS-Schneider VariAS-Blocks are designed to replace conventional, multiple-valve installations and are close-coupled to the process piping flange, for connecting process to instruments. The primary isolation valve needs to be of process design. Primary and Secondary Isolation Valve are, as standard, ball type valves with floating ball, the bleed valve can be provided as needle type valve with a screwed bonnet as well as ball type valve with a 3-way T-Port ball. The Standard Pressure Instrument Connection is 1/2 NPT female, the Standard Process Connections are provided with Flange Connections acc. to ASME B 16.5. AS-Schneider VariAS-Blocks is provided with an axial outlet and normally used for Vertical Installations (Vertical Tap). The VariAS-Blocks are available as Single Block and Bleed or Double Block and Bleed designs. Options like Sampling and Injection Applications are also available. The VariAS-Blocks are available with Bore Size 10, 14 and 20 mm.
- USD

Type D5 5-Valve Manifolds
8443
AS-Schneider Type D5 5-valve Manifolds for differential pressure gauges are available with a centre to centre distance of 37 mm or 54 mm as standard. The instrument connections are supplied with a Swivel Nut or a Swivel Male Connection. The standard vent connection is 1/4 NPT female. Pipe plugs are not installed as standard.
- USD

Type D3 3-Valve Manifold
8449
AS-Schneider Type D3 3-Valve Manifold for differential pressure gauges are available with a centre to centre distance of 37 mm or 54 mm as standard. The instrument connections are supplied with a Swivel Nut or a Swivel Male Connection. Vent ports are not provided as standard.
- USD

Type E5A/E5U 5-Valve Manifold
8454
AS-Schneider EDM Series 5 Valve Enclosure Manifolds are manufactured for applications that require the transmitter to be mounted in an enclosure for environmental protection. The standard instrument connection is: Flange connection for direct mounting to Pressure Transmitters in accordance with DIN EN 61518 / IEC 61518. The standard vent connection is 1/4 NPT female. Pipe plugs are not installed as standard. The 5 Valve Manifolds are available with 2 standard flow schematics (pattern): Standard (Double Isolate/Single Equalize/Double Vent and the 2nd one but with (Double Isolate/Single Equalize/Double Upstream Vent). AS-Schneider Enclosure Systems have been developed to provide a weatherproof barrier for every type of installation. Modern process measurement instrumentation needs protection not only from the effects of sun, rain, frost, aggressive atmosphere or dirt but also from accidental damage or unauthorized access. The Enclosure Manifolds allow direct mounting to a baseplate or a backplate of the enclosures. A lot of accessories such as electrical heating systems, thermostats, junction boxes, grommets and pipe stands are available. Designed and fitted out to customer˜s specifications AS-Schneider is supplying the complete solution – enclosure, manifolds and all accessories needed “ for an easy on-site installation.
- USD

Type E3A 3-Valve Manifold
8462
AS-Schneider EDM Series 3 Valve Enclosure Manifolds are manufactured for applications that require the transmitter to be mounted in an enclosure for environmental protection. The standard instrument connection is: Flange connection for direct mounting to Pressure Transmitters in accordance with DIN EN 61518 / IEC 61518. Vent ports are not provided as standard. AS-Schneider Enclosure Systems have been developed to provide a weatherproof barrier for every type of installation. Modern process measurement instrumentation needs protection not only from the effects of sun, rain, frost, aggressive atmosphere or dirt but also from accidental damage or unauthorized access. The Enclosure Manifolds allow direct mounting to a baseplate or a backplate of the enclosures. A lot of accessories such as electrical heating systems, thermostats, junction boxes, grommets and pipe stands are available. Designed and fitted out to customer˜s specifications AS-Schneider is supplying the complete solution – enclosure, manifolds and all accessories needed “ for an easy on-site installation.
- USD

Type E2A 2-Valve Manifold
8467
AS-Schneider EDM Series 2 Valve Enclosure Manifolds are manufactured for applications that require the transmitter to be mounted in an enclosure for environmental protection. Standard Instrument connections are Flange connection for direct mounting to Pressure Transmitters in accordance with DIN EN 61518 / IEC 61518, 1/2 NPT female or swivel nut G 1/2 resp. M20 x 1,5. The standard vent connection is 1/4 NPT female. Pipe plugs are not installed as standard. AS-Schneider Enclosure Systems have been developed to provide a weatherproof barrier for every type of installation. Modern process measurement instrumentation needs protection not only from the effects of sun, rain, frost, aggressive atmosphere or dirt but also from accidental damage or unauthorized access. The Enclosure Manifolds allow direct mounting to a baseplate or a backplate of the enclosures. A lot of accessories such as electrical heating systems, thermostats, junction boxes, grommets and pipe stands are available. Designed and fitted out to customer˜s specifications AS-Schneider is supplying the complete solution – enclosure, manifolds and all accessories needed “ for an easy on-site installation.
- USD

Type 5D 5-Valve Manifolds
8471
CoplanarTM Style with ‘Natural Gas Metering Pattern' – Female x Flanged AS-Schneider Type 5D 5-Valve Integral Manifolds with Natural Gas Metering Pattern – CoplanarTM Style is designed for direct mounting to Rosemount 2051/3051 CoplanarTM Pressure Transmitters. The standard vent connection is 1/4 NPT female. Pipe plugs are not installed as standard.
- USD