close
Filter By
Company
Ambient Temperature
Material Spec
Temperature Range
Thermostats
6 items

Duostats
2176
The Clorius Duostats are thermostats, type V, which via two sensing elements in a common hydraulic system act on one and the same control valve. Two basic types are available: Clorius V4.05- or Clorius V4.10 duostat, depending on the preferable proportional band PB, and the valve size. The sensing elements are two spiral sensors for the ventilation duct or two-rod sensors (a combination of one spiral sensor and one-rod sensor may be supplied in certain combinations). The effect, which the two sensing elements have on the adjustment, is proportional to the liquid volume of the individual sensors. Duostats are therefore available with varying proportions between the liquid volumes of the two sensors (sensor proportions) and in that way they can meet the requirements made by a number of different adjustment problems. As the adjustment result is a weighted average value of the temperatures of the two sensors, noï¬xed adjustment value can be indicated. Hence, Duostats are not equipped with a temperature scale, but with a marking for adjustment towards higher or lower temperatures, respectively.
- USD

RT Thermostat
5303
The Danfoss RT thermostats include a temperature-controlled, single-pole change over switch where the contact position depends on the temperature of the sensor and the set scale value. The Danfoss RT series consists of thermostats with room sensors, duct sensors and capillary tube sensors for general industrial and marine applications. Available types: RT 9 Thermostat RT 13 Thermostat RT 2,3,7 Thermostat RT 8 Thermostat RT 12 Thermostat RT 14 Thermostat RT 26 Thermostat RT 23 Thermostat RT 15 Thermostat RT 101 Thermostat RT 106 Thermostat RT 108 Thermostat RT 107 Thermostat RT 120 Thermostat RT 123 Thermostat RT 124 Thermostat RT 17 Thermostat RT 11 Thermostat RT 34 Thermostat RT 4 Thermostat RT 115 Thermostat RT 103 Thermostat RT 140 Thermostat RT 141 Thermostat RT 102 Thermostat
- USD

MBC 8000 / 8100 Thermostat
5315
The Danfoss MBC 8000 and MBC 8100 thermostats designed for use in severe industrial and marine applications where space and reliability are the essential features. MBC 8100 have all international marine approvals. According to Danfoss block design, both MBC thermostats are designed to survive in the harsh conditions known from machine rooms, among others. In addition, the Danfoss MBC 8000 and Danfoss MBC 8100 have high vibration resistance. The sensor on MBC 8100 thermostat contains an adsorption charge. Therefore its function is not affected whether the sensor is placed warmer or colder than the remaining part of the thermostatic element (bellows and capillary tube). However, a charge is sensitive to changes in the temperature of the bellows and capillary tube. Under normal conditions, this is of no importance, but if the thermostat is used in extreme ambient temperatures, the setting point might change.
- USD

Thermostat Stainless Steel
9139
The Clorius thermostat made out of stainless steel is particularly suitable for installation in demanding environments such as tank installations, outdoor plants and where it must be non-magnetic, e.g. in submarines. Function The adjusting cylinder of the thermostat is set at the temperature in ºC for the required heated medium. The temperature is regulated by the thermostatically controlled valve reducing or increasing the flow of the heating medium. Together with the adjusting cylinder, the liquid-ï¬lled sensor and capillary tube constitute a closed system. If the temperature of the medium to be heated is above the required level, the sensor liquid expands, causing the spindle of the thermostat to act upon the valve, thereby reducing the flow of the heating medium. If the temperature is below the required level, the temperature of the liquid in the sensor decreases and the volume is reduced, thereby the valve spring opens the valve causing an increased flow of the heating medium. Construction The parts of the thermostat are made of stainless steel. The thermostat consists of a liquid-ï¬lled sensor, a capillary tube, and an adjusting cylinder. The adjusting cylinder has O-ring sealings and is sealed with silicone glue at the top for hermetical closure. The thermostat is available with settings between -30ºC and +280ºC. At flow temperatures above 170ºC, a cooling unit must be installed between the valve and the thermostat. Please see datasheet no. 8.5.00.
- USD

V2 / V4 / V8 Self-Acting Thermostats
9143
The temperature controller, which consists of a thermostat and a valve, is used to control the temperature in central heating systems, district heating systems, industrial plants or industrial processes, and marine systems. The Clorius V2 / V4 / V8 Self-Acting Thermostats can be used to control cold or hot water, steam or oil in heating and cooling systems. Thermostat A thermostat consists of a sensor and a capillary tube, ï¬ filled with liquid, and an adjusting cylinder. The thermostat type designations and technical data are speciï¬ ed in ï¬ g. 2. With temperatures above 170ºC, a cooling unit must be ï¬ fitted between the valve and the thermostat – see ï¬ g. 1. The thermostat is self-acting and works on the principle of liquid expansion, it is sturdy in its design, and works with a large closing force – see ï¬ g. 2 Sensor The following sensor types are available : Rod sensor in copper or stainless steel and spiral sensor in copper with threaded connection according to ISO R7/1. Spiral sensor (copper only) with air duct flange. Rod/spiral sensor with steel flange DN 50, PN 40 and DN 50, PN 160. Sensor without connection. Usually used with capillary pack box for temperature control in tanks. Capillary Tube The capillary tube is made of copper, stainless steel, or PVC-coated copper but can also be delivered with flexible iron tube protection.
- USD

KP Thermostat
9384
The Danfoss KP Thermostats are single-pole, double-throw (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kW or installed in the control circuit of DC motors and large AC motors. The Danfoss KP Thermostats are used for regulation but can also be seen in safety monitoring systems. The KP thermostats are available with vapour charge or with adsorption charge. With a vapour charge, the differential is minimal. The KP Thermostats with adsorption charge Available types: KP 61 Thermostat KP 62 Thermostat KP 63 Thermostat KP 68 Thermostat KP 69 Thermostat KP 71 Thermostat KP 73 Thermostat KP 75 Thermostat KP 77 Thermostat KP 79 Thermostat KP 81 Thermostat KP 98 Thermostat
- USD
1 - 6 of 6
1