close
Categories
Filter By
Company
Accuracy
Ambient Temperature
Approvals
- ATEX 2
- ATEX - 2 GD Zone 1__EHEDG 3A__FM Class 1 div 2 1
- ATEX - 2 GD Zone 1__FM Class 1 div 2 1
- ATEX__cCSAus__IECEx 1
- ATEX__CSA__EAC__FM__IECEx__NEPSI 2
- ATEX__CSA__EEx (ia) IIC T3-T6__UL 1
- ATEX EEx (ia) IIC T3-T6 1
- CE__cULus__EAC__KCC__ROHS__Tick 1
- Danak__MI-001__OIML R49__PTB 1
- Danak__MI-001__OIML R49__PTB__R117__R75 1
- EEx (ia) IIC T3-T6 1
- MID__PTB 2
Connection Type
- 40 mm__50 mm 1
- ANSI Flange__DIN Flange 1
- BSP ISO 228__NPT__ DN 50 1
- G 1 1
- G 1¼ 1
- G 1¼ male thread 2
- G1__G2__G¼__G½__G¾ 1
- G1__G¼__G½__G¾ 2
- G 1__M33 x 2 1
- G1-ISO 228 male 1
- G 1 male thread 1
- G1 male thread 2
- G2 2
- G½ 2
- G½-ISO 228 male 1
- G½-ISO 228 male__G¾-ISO 228 1
- G½ male 1
- G¾ 5
- G…œ 1
- Surface mounting 1
- Via subplate with lateral female thread connection 2
Flow Rate (l/min)
Material Spec
Measuring range
Medium Temperature
- 0...20°C__0...60°C 1
- 0...85°C 2
- 0...90°C 1
- 0...90°C__95°C 2
- 2€°200°C__ 150°C 1
- 5...60°C 1
- -10€°160°C 1
- -10...60°C 5
- -20°200°C 1
- -20...90°C 3
- -20...110°C 1
- -20...130°C__-20...150°C 1
- -25...100°C 3
- -25...100°C__0...20°C 1
- -25...110°C 3
- -30...150°C 1
- -30...200°C 1
- -40...120°C 2
- -50°180°C 3
- Max. 85°C 5
- Max. 100°C 2
- Max. 120°C 1
- Max. 150°C 1
Nominal Diameter
Nominal Size
Pressure Range
Switching Function
Temperature Range
Flow
91 items

VH500 Paddle Flow Switch
1035
The SIKA VH500 paddle flow switch is modelled for applications such as cooling water monitoring, leak monitoring, and lubrication control. The SIKA VH 500 is placed with its paddle in flowing medium, which triggers the paddle. The resulting dynamic pressure causes the paddle to travel, which causes the actuation of integrated micro switches. SIKA flow switches monitor the flow of low-viscosity media in pipes. They offer a reliable solution for ensuring the minimum flow rate and thereby protecting high-quality systems and installations from damages. These flow switches work based on the well- established mechanical operating principles. Thanks to the different paddle lengths, the switch points of the paddle flow switches can be configured for a wide switching range.
- USD

CONTOIL VZO II 15-50
11420
The CONTOIL VZO II 15-50 is a versatile flow meter for oil, heavy oil and many other oil-like liquids. The CONTOIL VZO II 15-50 is used for efficient consumption measurement of heat burners and various combustion engines. A reliable solution for any application where oil is consumed. The flow meter comes in sizes variating from DN15 to 50. CONTOIL® fuel oil meters work on the volumetric principle of rotary piston meters (positive displacement meters). The main features of this measuring principle are large measuring ranges, high accuracy, suitability for high viscosities and independence from the power supply. The CONTOIL VZO II has a mechanical measuring heart in comparison to the VZF II, which results in an analogue display. Flow disturbances do not influence proper operation. Leading manufacturers of oil burners and operators of heating systems, ships or diesel engines rely on CONTOIL® fuel oil meters “ and with good reasons.
- USD

DFM 8D
11424
The Aquametro DFM 8D is a small flow measurement device for monitoring fuel consumption measurement for trucks, buses, trains, construction and agricultural machinery, small boats and generators, and burners. The Aquametro DFM 8D can be mounted on the pressure or suction side of a pump. Because no straight inlet/outlet sections are required, making it a very space-saving installation. Create minimum failure costs due to simple function monitoring, rapid fault analysis and the possibility of simple repairs on site. The Aquametro DFM 8D is you go to.
- USD

DFM Board computer
11428
The CONTOIL DFM board computer is a suitable computer and display covering all direct and differential applications in fuel metering. The DFM board computer can be used for all available flowmeter sizes. The Aquametro DFC board computer is designed for acquisition, calculation, displaying and sending data. Resulting from incorrect use or from use other than that designated can suspend the operational safety of the devices. The manufacturer accepts no liability for damages being produced from this.
- USD

BNA Bypass Level Indicator
1655
The bypass level indicator BNA consists of a bypass chamber, which, as a communicating tube, is connected laterally to a vessel via at least two process connections (flanged, threaded or welded). Through this type of arrangement, the level in the bypass chamber corresponds to the level in the vessel. The float with a built-in permanent magnetic system, which is mounted within the bypass chamber, transmits the liquid level, contact-free, to the magnetic display mounted to the outside of the bypass chamber. In this are fitted, at 10 mm intervals, two-coloured plastic rollers or stainless steel flaps with bar magnets. Through the magnetic field of the permanent magnetic system in the float, the display elements, through the wall of the bypass chamber, are turned through 180°. For an increasing level from white to red; for a falling level from red to white. Thus the bypass level indicator clearly displays the level of a vessel without power supply.
- USD

FRL Electronic Oil Flow Meter
2026
TOKICO has a long history of producing high-quality flow meters since 1950 in the fuel measurement field. Its flowmeters are used in a wide variety of applications including measuring of boiler fuel oil and diesel oil, as well as for transactions for kerosene, light oil, and heavy oil.
- USD

CONTOIL VZF II 15-50
2430
The CONTOIL VZF II 15-50 is a versatile flow meter for oil, heavy oil and many other oil-like liquids. The CONTOIL VZF II 15-50 is used for efficient consumption measurement of heat burners and various combustion engines. A reliable solution for any application where oil is consumed. The flow meter comes in sizes variating from DN15 till 50. CONTOIL® fuel oil meters work on the volumetric principle of rotary piston meters (positive displacement meters). The main features of this measuring principle are large measuring ranges, high accuracy, suitability for high viscosities and independence from the power supply. Flow disturbances do not influence proper operation. Leading manufacturers of oil burners and operators of heating systems, ships or diesel engines rely on CONTOIL® fuel oil meters – and with good reasons.
- USD

VTY 20 Turbine Flow Sensor
2808
The SIKA VTY 20 turbine flow sensor gives you precise and robust products to measure flow rates or total flows, for water and water mixtures. Turbine flow sensors of the series VTY stainless steel were specially developed for the use in industrial applications. The sensors are particularly suitable for use in, e.g. dosing systems, heaters, coolers or temperature control units. The liquid flowing into the turbine flow sensor is split into individual jets by the flow straightener. These jets hit the rotor evenly, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets, and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. Given the uniform inflow to the bearing, the forces largely cancel themselves out and wear reduced to a minimum. The sturdy bearing materials – sapphire and hard metal – also guarantee an exceptionally long endurance.
- USD

SITRANS F M MAG 1100
3497
The SIEMENS SITRANS F M MAG 1100 is a wafer design sensor in stainless steel with highly resistant liners and electrodes designed for the general industry environment. The flangeless wafer design meets all flange standards. The SITRANS F M MAG 1100 is used in all industries. The corrosion-resistant stainless steel housing and the highly resistant liner and electrodes fit even the most extreme process media. To have a complete flowmeter, please combine it with one of the following MAG transmitters: SITRANS F M MAG 5000 SITRANS F M MAG 6000 SITRANS F M MAG 6000 I
- USD