close
Filter By
Company
Accuracy
Ambient Temperature
- 0...50°C 3
- 0...55°C 1
- 0...60°C 1
- 0...70°C 3
- 0...85°C 1
- 0...100°C 2
- 0...125°C 1
- 0...200°C 1
- 10...40°C 1
- -10...60°C 1
- -10...70°C 5
- -20°60°C 15
- -20...50°C 2
- -20...60°C 25
- -20...70°C 4
- -20...80°C 5
- -25...70°C 4
- -25...80°C 3
- -25...85°C 4
- -25...100°C 1
- -30...70°C 1
- -30...80°C 1
- -40...60°C 13
- -40...65°C 3
- -40...70°C 4
- -40...80°C 4
- -40...85°C 3
- -40...100°C 5
- -40...125°C 1
- -50...65°C 1
- -50...70°C 2
- -70...60°C 1
Connection Type
- 2 x G ¼ B female__2 x G ½ B male__½ NPT male 1
- 2 x G½ female, lower mount (LM) 1
- Clamp connection per DIN 32676 / ISO 2852 / BS4825 1
- Copper alloy, lower mount (LM) G 1/4 B (male), 14 1
- G ¼__SW 14 1
- G¼__SW 14 1
- G ¼ B (male)__Stainless steel 316L 1
- G ¼ B__G …› B__¼ NPT__…› NPT 1
- G ¼ B female__G ½ B male__½ NPT male 1
- G ½__G¼__SW 14__SW 17__SW 22 1
- G ½__Lower mount__SW22 1
- G ½ B 1
- G ½ B__½ NPT__½ NPT female 1
- G ½ B female__G ½ B male__½ NPT male 1
- NS 40: G 1/8 B (male) NS 50, 63: G 1/4 B (male), 1
Filling
Material Spec
Medium Temperature
Nominal Size
Size
-20...60°C - 0...50°C
28 items
611.13 Capsule Pressure Gauge
6952
The WIKA 611.13 capsule pressure gauges is based upon a modular capsule measuring system. One half of the capsule element forms the plastic case, and the other half is made of copper-beryllium. The capsule measuring principle is particularly suitable for low pressures. On pressurisation, the expansion of the capsule element, proportional to the incident pressure, is transmitted to the movement and indicated. The modular design enables a multitude of customer-specific applications. The WIKA 611.13 capsule pressure gauge is used with great success, particularly in medical applications.
- USD
614.11 / 634.11 Capsule Pressure Gauge
6956
The WIKA 614.11 and 634.11 capsule pressure gauges are based upon the proven capsule measuring system. The capsule measuring principle is particularly suitable for low pressures. On pressurisation, the expansion of the capsule element, proportional to the incident pressure, is transmitted to the movement and indicated. The modular design enables a multitude of combinations of case materials, process connections, nominal sizes and scale ranges. Due to this high variance, regarding design and back mount connection, the instrument is suitable for panel mounting in a wide range of applications.
- USD
632.51 Capsule Pressure Gauge
6961
The WIKA 632.51 capsule pressure gauge developed for gaseous, aggressive media, for both none- and aggressive environments. The 632.51 robust design and ingress protection IP54, suitable for outdoor use. With its high overload safety up to 50 x full-scale value and low measuring error and influence on function from medium pollution makes this the ideal capsule pressure gauge for the process industry.
- USD
PGS43.1x0 Pressure Gauge
7146
Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the WIKA PGS43.100 or PGS43.160 switchGAUGE can be used. Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window. Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.
- USD
PGS21.1x0 Bourdon Tube Pressure Gauge
7150
Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the WIKA PGS21.100 and PGS21.160 switchGAUGE finds its use. Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window. Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.
- USD
PGS23.063 Bourdon Tube Pressure Gauge
7155
Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the WIKA PGS23.063 switchGAUGE finds its use. Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instruments. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window. Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.
- USD
DPGS43.1x0 Differential Pressure Gauge
7159
Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the WIKA DPGS43.100 or DPGS43.160 switchGAUGE finds its use. Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the pointer position of the pressure gauge. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window. Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The differential pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.
- USD
532.53+8xx Pressure Gauge
7163
Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the WIKA 532.53+8xx switchGAUGE finds its use. Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instruments. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window. Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas.
- USD
ER2000-P Electric Controller
9171
The Clorius ER 2000-P controller is used for constant pressure control. It is suitable for all heating and cooling control systems. The controller is primarily intended for marine installations and other industrial applications. Design The ER 2000-P controller is designed for panel mounting. For an easy start-up, it has optimization for the automatic determination of favourable control parameters. The optimization starts when changing the set point or when switching over from manual mode to automatic control. The optimization can be disregarded. For easy operation, it has three keys – two for scrolling or changing values and an enter key. Two digital displays show the process variable and the setpoint. 3 LEDs indicate actuator opens, actuator closes and alarm. The controller can be switched from auto mode to manual mode. In manual mode, the actuator can be opened, closed or stopped in a certain position. Three different alarm settings are possible: Alarm at a deviation from the setpoint SP Alarm at a fixed limit value Alarm at leaving a band around the setpoint SP It can operate either as a three-position or as a two-position controller or analogue controller (4-20 mA) and has an adjustable proportional band, integral action time and derivative action time. Function The pressure input comes via a 4-20 mA signal. The measured value of the controlled variable is compared with the setpoint value and adjusted via a PI or a PID control structure. The ER 2000-P permits direct reading of the actual temperature value (PV) and it is secured from failure in the measuring circuit, i.e. the controller can be set to give either a closing, an opening or remain in current position command in case of sensor short circuit or sensor break. The error message Err appears in the LED display PV.
- USD