close
Filter By
Company
Accuracy
- 0.01% FS 4
- 0.1%__±0.1 mm 7
- 0.1 mm 2
- 0.02% FS 2
- 0.2%__±1 mm/s 6
- 0.2%__±2.5 mm/s 1
- 0.2% FS 1
- 0.3% FS 1
- 0.3...0.1 1
- 0.04%__0.065% 1
- 0.4 %__± 1 mm/s 1
- 0.5% FS 2
- 0.6%__1% 1
- 0.10% 1
- 0.15% 1
- 0.025%__0.1% 1
- 0.25% 4
- 0.30% 1
- 0.50% 22
- 2.3% FS 1
- 2.5 1
- 3...24 mm 2
- 4% 1
- ±0.2 l/min 1
- ± 0.3%__± 1.5% 2
- ±0.4 l/min 3
- ± 0.5% FS 3
- ± 0.5% FS__± 1% FS 1
- ±0.5% of flow rate 1
- ±0.10 % 1
- ±0.10 %__±0.20 % 1
- ±1% 3
- ±1 % of range, ±3 % of reading (from 15 l/min) 1
- ±1.5mm 1
- ±1.25 mm 1
- ± 1__± 3% 1
- ± 2%__± 2°C 4
- ± 2°C 1
- ±2mm 4
- ±3°C 1
- ± 3 mm 2
- ± 5% 5
- EN1434 Class 3, typical ±(0.5 + 3K/ΔΘ) [%] 1
Approvals
Connection Type
Flow Rate (l/min)
Medium Temperature
Nominal Diameter
Pressure Range
± 1__± 3%, ±1 % of range, ±3 % of reading (from 15 l/min) - ± 0.5% FS__± 1% FS
3 items
MBS 4201/4251/4701/4751 Pressure Transmitter
5145
The intrinsically safe Danfoss MBS 4201, MBS 4251, MBS 4701 and MBS 4751 pressure transmitter program is designed for use in hazardous environments. It offers a reliable pressure measurement, even in harsh applications with severe medium influences like cavitation, liquid hammer or pressure peaks. The Danfoss MBS 4201 and MBS 4251 pressure transmitters are Ex ia IIC T6…T4 explosion protected according to the ATEX directive 94/9/EC. In contrast, the Danfoss MBS 4701 and MBS 4751 pressure transmitters are Ex ia IIC T4 explosion protected. Both series come with 4“20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0…600 bar, zero point and span adjustment, plug connection and a wide range of pressure connections. Excellent vibration stability, robust construction, and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements.
- USD
VTL 20 Turbine Flow Sensor
7811
The SIKA VTL 20 turbine flow sensor is made for flow measurement or dosing applications for liquids. Because of the very compact design, the extensive measuring range and the convincing precision of measurements, almost unlimited applications are possible. The sturdy bearing materials – sapphire and tungsten carbide – also guarantee an exceptionally long endurance. The liquid flowing into the SIKA VTL 20 turbine flow sensor is split into individual jets by the guiding blade. These jets hit the rotor evenly from different directions, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. The construction of the guiding blade and rotor enables to realize the very low start-up flow values.
- USD
VTH 20 Turbine Flow Sensor
7813
The SIKA VTH 20 turbine flow sensor is made for flow measurement or dosing applications for liquids. Because of the very compact design, the extensive measuring range and the convincing precision of measurements, almost unlimited applications are possible. The sturdy bearing materials – sapphire and tungsten carbide – also guarantee an exceptionally long endurance. The liquid flowing into the SIKA VTH 20 turbine flow sensor is split into individual jets by the guiding blade. These jets hit the rotor evenly from different directions, setting the rotor in motion. The rotation speed of the rotor is then converted to an electrical pulse signal (frequency): The rotor is fitted with magnets and a Hall effect sensor detects the rotation of the rotor. A flow-proportional frequency signal (square-wave signal) is made available. The construction of the guiding blade and rotor enables to realize the very low start-up flow values.
- USD
1 - 3 of 3
1